Search result
"VX-ODS" Filtered 12 Item.
LC
- Samples
- p-Hydroxybenzoic acid , m-Hydroxybenzoic acid , Phenol , Acetylsalicylic acid , Benzoic acid , Salicylic acid
- Applications
- Acidic compounds
- Column
- VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 10 mM (NH4)3PO4(pH 2.5)/CH3CN = 80/20
- Frow rate
- 1.0 mL/min
- Column temp.
- 30°C
View detail
LC
- Samples
- Pyridine , Phenol
- Applications
- Pyridine, Phenol test
- Column
- VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- CH3CN/H2O = 30/70
- Frow rate
- 1.0 mL/min
- Column temp.
- 30°C
View detail
LC
- Samples
- Inosine 5'-monophosphate , Pyroglutamic acid
- Applications
- 5'-IMP(Inosinic acid), Pyroglutamic acid
- Column
- VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM Phosphoric acid buffer(pH 6.7)/CH3OH = 99/1
- Frow rate
- 1.0 mL/min
- Column temp.
- 40°C
View detail
LC
- Samples
- β-Carotene
- Applications
- β-Carotene
- Column
- VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- CH3OH/Tetrahydrofuran = 9/1 + 0.05% BHT
- Frow rate
- 1.0 mL/min
- Column temp.
- 40°C
View detail
LC
- Samples
- Glycyrrhizin
- Applications
- Glycyrrhizin
- Column
- VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM KH2PO4(pH 4.6)/CH3CN = 7/3
- Frow rate
- 1.0 mL/min
- Column temp.
- 30°C
View detail
LC
- Samples
- Glycyrrhetic acid
- Applications
- Glycyrrhetic acid
- Column
- VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM KH2PO4(pH 4.6)/CH3CN = 1/4
- Frow rate
- 1.0 mL/min
- Column temp.
- 30°C
View detail
LC
- Samples
- Oxalic acid , Nitric acid
- Applications
- Oxalic acid (COO-)2, Nitric acid(NO3-)
- Column
- VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM KH2PO4(pH 2.2)/CH3OH = 91/9 + 2 mM Tetrabutylammonium bromide
- Frow rate
- 1.0 mL/min
- Column temp.
- ambient
View detail
LC
- Samples
- Nicotinic acid , Nicotinic acid amide , Calcium pantothenate , Pyridoxine hydrochloride , Riboflavin phosphate , Thiamine , Folic acid , Biotin , Riboflavin
- Applications
- The water-soluble vitamin
- Column
- VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM H3PO4/5 mM Sodium 1-hexanesulfonate = 91/9
- Frow rate
- 1.0 mL/min
- Column temp.
- 45°C
View detail
LC
- Samples
- Predonisone , Cortisone , Hydrocortisone , Cortisone acetate , Hydrocortisone acetate
- Applications
- Separation of the steroid
- Column
- VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- H2O/CH3OH/THF = 70/10/20
- Frow rate
- 1.0 mL/min
- Column temp.
- 40°C
View detail