Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Trichloroethylene" Filtered 14 Item.

Graph

GC

Samples
n-Hexane , Methyl Alcohol , Acetone , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Trichloroethylene , Isobutyl Alcohol , Isobutyl Acetate , Toluene , n-Butyl Acetate , Isoamyl Alcohol , Ethylbenzene , m-Xylene , o-Xylene , n-Propylbenzene , Cyclohexanone
Applications
Organic solvent in the air (ppm level)
Column
SBS-100 10% Shimalite TPA 60-80
Column Size
3.1m×3.2mm
Column temp.
110°C
Carrier gas
N2,30ml/min
Injection port temp.
200°C
Detector temp.
200°C(FID)

View detail


Graph

GC

Samples
Dichloromethane , trans-1,2-Dichloroethylene , Chloroform , 1,2-Dichloroethane , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Toluene , Tetrachloroethylene , Chlorobenzene , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
Applications
Organic solvents in work environment (3)
Column
SBS-300 20% Shimalite W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
100°C
Carrier gas
N2,30ml/min
Injection port temp.
240°C
Detector temp.
240°C(FID)

View detail


Graph

GC

Samples
Dichloromethane , trans-1,2-Dichloroethylene , Chloroform , 1,2-Dichloroethane , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Toluene , Tetrachloroethylene , Chlorobenzene , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
Applications
Chlorinated solvents of the atmosphere (ppm level)
Column
SBS-300 20% Shimalite W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
100°C
Carrier gas
N2,30ml/min
Injection port temp.
240°C
Detector temp.
240°C(FID)

View detail


Graph

GC

Samples
Chloroform , 1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Chlorodibromomethane , Tetrachloroethylene , Bromoform
Applications
Trihalomethane standard mixed sample (2)
Column
Silicone DC 200 20% Chromosorb W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
80°C
Carrier gas
N2,60ml/min
Injection port temp.
220°C
Detector temp.
220°C(ECD)

View detail


Graph

GC

Samples
1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Tetrachloroethylene
Applications
Trihalomethane under drainage
Column
Silicone DC 200 20% Chromosorb W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
85°C
Carrier gas
N2,60ml/min
Injection port temp.
220°C
Detector temp.
220°C(ECD)

View detail


Graph

GC

Samples
Chloroform , 1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Tetrachloroethylene , Chlorodibromomethane , Bromoform
Applications
Trihalomethane standard mixed sample (1)
Column
Silicone DC 550 20% Chromosorb W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
90°C
Carrier gas
N2,60ml/min
Injection port temp.
220°C
Detector temp.
220°C(ECD)

View detail


Graph

GC

Samples
Methanol , Ethyl Ether , Isopropanol , trans-1,2-Dichloroethylene , Ethyl Acetate , Chloroform , Isobutanol , Trichloroethylene , n-Butanol , 1,4-Dioxane , Toluene , Tetrachloroethylene , n-Butyl Acetate , Ethylbenzene , p-Xylene , Isoamyl Acetate , o-Xylene , n-Amyl Acetate , Cyclohexanol , Cyclohexanone , 2-Methylcyclohexanol , 2-Methylcyclohexanone , p-Dichlorobenzene , o-Dichlorobenzene , o-Cresol , m-Cresol
Applications
The work environment (2)
Column
ULBON HR-1701
Column Size
30m×0.53mm(5μm)
Column temp.
60°C→180°C(4°C/min)
Carrier gas
He,10ml/min
Detector temp.
200°C(FID)
Injection volume
1ml

View detail


Graph

GC

Samples
Solvents (4)
Applications
Solvents (4)
Column
ULBON HR-1701
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→180°C(4°C/min)
Carrier gas
He,1.4ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Methyl Isobutyl Ketone , Toluene , Methyl Butyl Ketone , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , 1,1,2,2-Tetrachloroethane , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Cresol , p-Cresol
Applications
The work environment (1)
Column
ULBON HR-52
Column Size
30m×0.53mm(5μm)
Column temp.
60°C→130°C(3°C/min)
Carrier gas
He,8.0ml/min
Detector temp.
150°C(FID)
Injection volume
1ml

View detail


Graph

GC

Samples
Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , 1,4-Dioxane , Methyl Isobutyl Ketone , Toluene , Methyl n-Butyl Ketone , n-Butyl Acetate , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , o-Xylene , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , 3-Methylcyclohexanol(cis, trans) , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Dichlorobenzene , o-Cresol , p-Cresol
Applications
Solvents (3)
Column
ULBON HR-52
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→130°C(3°C/min)
Carrier gas
He,1.2ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Dichloromethane , trans-1,2-Dichloroethylene , Chloroform , 1,2-Dichloroethane , 1,1,1-Trichloroethane , Carbon tetrachloride , Trichloroethylene , Toluene , Tetrachloroethylene , Chlorobenzene , 1,1,2,2,-Tetrachloroethane , o-Dichlorobenzene
Applications
Measurement of chlorinated solvents in air using Shinwasorb
Column
SBS-300 10% Shinwasorb-S 60/80
Column Size
3.1 m x 3.2 mm I.D. Glass
Column temp.
100℃
Carrier gas
30 mL/min N₂
Injection port temp.
240℃
Detector temp.
240℃
Detector
FID
Injection volume
1.0 mL

View detail


Graph

GC

Samples
1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Chlorodibromomethane , Tetrachloroethylene , Bromoform
Applications
Measurements of trihalomethanes using Shinwasorb -1-
Column
Silicone DC-200 10% Shinwasorb-S 60/80
Column Size
3.1 m x 3.2 mm I.D. Glass
Column temp.
100℃
Carrier gas
50 mL/min N₂
Injection port temp.
240℃
Detector temp.
240℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Chlorodibromomethane , Tetrachloroethylene , Bromoform
Applications
Measurements of trihalomethanes using Shinwasorb -2-
Column
Silicone DC-550 10% Shinwasorb-S 60/80
Column Size
3.1 m x 3.2 mm I.D. Glass
Column temp.
90℃
Carrier gas
50 mL/min N₂
Injection port temp.
220℃
Detector temp.
220℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Chloroform , Trichloroethylene , N,N-dimethylformamide ,
Applications
Analysis of tranilast using Sunpak-H ~Purity test (3) Chloroform~
Column
Sunpak-H 80/100
Column Size
1.1 m x 3.2 mm I.D. Glass
Column temp.
160℃
Carrier gas
45 mL/min N2
Injection port temp.
200℃
Detector temp.
200℃  
Detector
FID
Injection volume
1.0 μL

View detail