Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Fragrance" Filtered 9 Item.

Graph

GC

Samples
1,8-Cineole , β-Phenethyl Alcohol , Benzyl Acetate
Applications
Analysis of the fragrance of a flower using NeedlEx (for organic solvent) 1
Column
ULBON HR-1
Column Size
0.32mmI.D. × 30m (0.25um)
Column temp.
50°C→200°C(5°C/min)
Carrier gas
He,2.4ml/min
Detector temp.
250°C(FID)
Injection volume
-

View detail


Graph

GC

Samples
Linalool , Anisaldehyde , Geraniol , Perillaldehyde
Applications
Analysis of the fragrance of a flower using NeedlEx (for organic solvent) 2
Column
ULBON HR-1
Column Size
0.32mmI.D. × 30m (0.26um)
Column temp.
50°C→200°C(5°C/min)
Carrier gas
He,2.4ml/min
Detector temp.
250°C(FID)
Injection volume
-

View detail


Graph

GC

Samples
α-Pinene , Limonene , Isobornyl Acetate , α-Ionone
Applications
Analysis of the fragrance of a flower using NeedlEx (for organic solvent) 3
Column
ULBON HR-1
Column Size
0.32mmI.D. × 30m (0.26um)
Column temp.
50°C→200°C(5°C/min)
Carrier gas
He,2.4ml/min
Detector temp.
250°C(FID)
Injection volume
-

View detail


Graph

GC

Samples
Myrcene , 1,8-Cineole , L-Menthol , Anisaldehyde
Applications
Analysis of the fragrance of a flower using NeedlEx (for organic solvent) 4
Column
ULBON HR-1
Column Size
0.32mmI.D. × 30m (0.26um)
Column temp.
50°C→200°C(5°C/min)
Carrier gas
He,2.4ml/min
Detector temp.
250°C(FID)
Injection volume
-

View detail


Graph

GC

Samples
α-Pinene , 1,8-Cineole , β-Phenethyl Alcohol
Applications
Analysis of the fragrance of a flower using NeedlEx (for organic solvent) 5
Column
ULBON HR-1
Column Size
0.32mmI.D. × 30m (0.26um)
Column temp.
50°C→200°C(5°C/min)
Carrier gas
He,2.4ml/min
Detector temp.
250°C(FID)
Injection volume
-

View detail


Graph

GC

Samples
L-Menthon , Anisaldehyde , Geraniol , L-Perillaldehyde , α-Ionone
Applications
Analysis of the fragrance of a flower using NeedlEx (for organic solvent) 6
Column
ULBON HR-1
Column Size
0.32mmI.D. × 30m (0.26um)
Column temp.
50°C→200°C(5°C/min)
Carrier gas
He,2.4ml/min
Detector temp.
250°C(FID)
Injection volume
-

View detail


Graph

GC

Samples
Myrcene , Limonene
Applications
Analysis of the fragrance of a flower using NeedlEx (for organic solvent) 7
Column
ULBON HR-1
Column Size
0.32mmI.D. × 30m (0.26um)
Column temp.
50°C→200°C(5°C/min)
Carrier gas
He,2.4ml/min
Detector temp.
250°C(FID)
Injection volume
-

View detail


Graph

GC

Samples
Benzyl Alcohol , β-Phethyl Alcohol , Eugenol
Applications
Analysis of the fragrance of a flower using NeedlEx (for organic solvent) 8
Column
ULBON HR-1
Column Size
0.32mmI.D. × 30m (0.26um)
Column temp.
50°C→200°C(5°C/min)
Carrier gas
He,2.4ml/min
Detector temp.
250°C(FID)
Injection volume
-

View detail


Graph

GC

Samples
Fragrance
Applications
Measurements of fragrance using Shinwasorb
Column
Thermon-3000 5% Shinwasorb-S 80/100
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
80~260℃(6℃/min)
Carrier gas
50 mL/min N₂
Injection port temp.
280℃
Detector temp.
280℃
Detector
FID
Injection volume
1.0 μL

View detail