Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Hexane" Filtered 39 Item.

Graph

GC

Samples
n-Hexane , Methyl Alcohol , Acetone , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Trichloroethylene , Isobutyl Alcohol , Isobutyl Acetate , Toluene , n-Butyl Acetate , Isoamyl Alcohol , Ethylbenzene , m-Xylene , o-Xylene , n-Propylbenzene , Cyclohexanone
Applications
Organic solvent in the air (ppm level)
Column
SBS-100 10% Shimalite TPA 60-80
Column Size
3.1m×3.2mm
Column temp.
110°C
Carrier gas
N2,30ml/min
Injection port temp.
200°C
Detector temp.
200°C(FID)

View detail


Graph

GC

Samples
Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
Applications
Organic solvent in work environment (2)
Column
SBS-200 20% Shimalite W 100-120 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
100°C
Carrier gas
N2,50ml/min
Injection port temp.
240°C
Detector temp.
240°C(FID)

View detail


Graph

GC

Samples
Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
Applications
Organic solvents of the atmosphere (ppm level)
Column
SBS-200 20% Shimalite W 100-120 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
100°C
Carrier gas
N2,50ml/min
Injection port temp.
240°C
Detector temp.
240°C(FID)

View detail


Graph

GC

Samples
n-Pentane , n-Hexane , n-Heptane , n-Octane , Acrolein , Carbon Tetrachloride , Benzene , Acrylonitrile , Acetonitrile , Perchloroethylene , Toluene , Ethylbenzene , m-Xylene , o-Xylene , n-Dodecane , Styrene monomer , n-Tridecane , p-Xylene
Applications
Organic solvent in work environment (1)
Column
Thermon-1000 25% Shimalite 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
130°C
Carrier gas
N2,40ml/min
Injection port temp.
240°C
Detector temp.
240°C(FID)

View detail


Graph

GC

Samples
Ethanol , Acetonitrile , Isopropanol , n-Hexane
Applications
Lower alcohol in water and Hydrocarbon
Column
Thermon-1000 5% Sunpak-A
Column Size
2.1m×3.2mm
Column temp.
180°C
Carrier gas
N2,50ml/min
Injection port temp.
250°C
Detector temp.
230°C(FID)

View detail


Graph

GC

Samples
Pynacol , Butanediol(1,4) , Pentanediol(1,5) , Hexanediol(1,6) , Heptanediol(1,7) , Octanediol(1,8) , Nonanediol(1,9) , Decanediol(1,10)
Applications
Diols (standard mixed sample)
Column
Thermon-3000 10% Chromosorb W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
228°C
Carrier gas
N2,60ml/min
Injection port temp.
270°C
Detector temp.
260°C(FID)

View detail


Graph

GC

Samples
n-Pentane , n-Hexane , Benzene , iso-Octane , Toluene , Ethylbenzene , m-Xylene , o-Xylene , p-Xylene
Applications
Premium gasoline
Column
ULBON HR-1
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→220°C(4°C/min)
Carrier gas
He,0.75ml/min
Detector temp.
250°C(FID)
Injection volume
0.5μl

View detail


Graph

GC

Samples
n-Pentane , n-Hexane , Benzene , iso-Octane , Toluene , Ethylbenzene , m-Xylene , o-Xylene , p-Xylene
Applications
Regular gasoline
Column
ULBON HR-1
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→220°C(4°C/min)
Carrier gas
He,0.75ml/min
Detector temp.
250°C(FID)
Injection volume
0.5μl

View detail


Graph

GC

Samples
Solvents (4)
Applications
Solvents (4)
Column
ULBON HR-1701
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→180°C(4°C/min)
Carrier gas
He,1.4ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
n-Hexane , Ethyl Ether , Acetone , Methyl Acetate , trans-1,2-Dichloroethylene , Methanol , Isopropyl Acetate , Isopropanol , Dichloromethane , n-Propyl Acetate , cis-1,2-Dichloroethylene , Methyl Isobutyl Ketone , Chloroform , Toluene , 1,4-Dioxane , Isobutanol , Isoamyl Acetate , Ethylbenzene , p-Xylene , m-Xylene , Methyl Cellosolve , o-Xylene , Ethyl Cellosolve , Styrene , Cellosolve Acetate , N,N-Dimethylformamide , 4-Methylcyclohexanone , Butyl Cellosolve , cis-4-Methylcyclohexanol , m-Dichlorobenzene , p-Dichlorobenzene , trans-4-Methylcyclohexanol , o-Dichlorobenzene , o-Cresol , p-Cresol , m-Cresol
Applications
Solvents (6)
Column
ULBON HR-20M
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→240°C(3°C/min)
Carrier gas
He,1.3ml/min
Detector temp.
250°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Methyl Isobutyl Ketone , Toluene , Methyl Butyl Ketone , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , 1,1,2,2-Tetrachloroethane , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Cresol , p-Cresol
Applications
The work environment (1)
Column
ULBON HR-52
Column Size
30m×0.53mm(5μm)
Column temp.
60°C→130°C(3°C/min)
Carrier gas
He,8.0ml/min
Detector temp.
150°C(FID)
Injection volume
1ml

View detail


Graph

GC

Samples
Methanol , Ethanol , Acetone , n-Propanol , n-Hexane , Ethyl Acetate , Chloroform , Benzene , MIBK , Toluene , Isobutyl Acetate , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cellosolve Acetate
Applications
Solvents (1)
Column
ULBON HR-52
Column Size
25m×0.32mm(0.5μm)
Column temp.
40°C→90°C(2°C/min)
Carrier gas
He,0.83ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , 1,4-Dioxane , Methyl Isobutyl Ketone , Toluene , Methyl n-Butyl Ketone , n-Butyl Acetate , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , o-Xylene , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , 3-Methylcyclohexanol(cis, trans) , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Dichlorobenzene , o-Cresol , p-Cresol
Applications
Solvents (3)
Column
ULBON HR-52
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→130°C(3°C/min)
Carrier gas
He,1.2ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
n-Hexane, Benzene , n-Octane , Toluene , n-Nonane , Ethylbenzene , p-Xylene , m-Xylene , o-Xylene , Isopropylbenzene , Styrene , n-Propylbenzene , p-Ethyltoluene , m-Ethyltoluene , o-Ethyltoluene , 1,3,5-Trimethylbenzene , 1,2,4-Trimethylbenzene , 1,2,3-Trimethylbenzene , 4-n-Propyltoluene , 3-n-Propyltoluene , 2-n-Propyltoluene , 1,2,3,5-Tetramethylbenzene , 1,2,4,5-Tetramethylbenzene , 1,2,3,4-Tetramethylbenzene
Applications
Alkyl benzene isomer
Column
ULBON Xylene Master
Column Size
50m×0.32mm
Column temp.
70°C→120°C(2°C/min)
Carrier gas
He,1.4ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Methyl mercuric chloride , Ethyl mercuric chloride
Applications
Measurement of alkyl mercury compounds (each 100 ppb in n-hexane) using Shinwasorb
Column
Thermon-HG 5% Shinwasorb-U 60/80
Column Size
0.5 m x 3.0 mm I.D. Glass
Column temp.
160℃
Carrier gas
50 mL/min N₂
Injection port temp.
250℃
Detector temp.
250℃
Detector
ECD
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Ethylbenzene , p-Xylene , m-Xylene , o-Xylene
Applications
Measurement of xylene isomers using Shinwasorb
Column
Shinchrom F51+Bentone 34 3+2% Shinwasorb-U 60/80
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
80℃
Carrier gas
40 mL/min N₂
Injection port temp.
240℃
Detector temp.
240℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Mixture of 13 organic solvents
Applications
Measurement of organic solvents using Shinwasorb -1-
Column
PEG1500 12.5% Shinwasorb-U 40/60
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
70℃
Carrier gas
40 mL/min N₂
Injection port temp.
200℃
Detector temp.
200℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Mixture of 22 organic solvents
Applications
Measurement of organic solvents using Shinwasorb -2-
Column
PEG1500 12.5% Shinwasorb-U 40/60
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
60~120℃ (4℃/min)
Carrier gas
40 mL/min N₂
Injection port temp.
200℃
Detector temp.
200℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Fragrance
Applications
Measurements of fragrance using Shinwasorb
Column
Thermon-3000 5% Shinwasorb-S 80/100
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
80~260℃(6℃/min)
Carrier gas
50 mL/min N₂
Injection port temp.
280℃
Detector temp.
280℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
200 ppm in hexane
Applications
Measurements of eucalyptus oil using Shinwasorb
Column
Thermon-3000 5% Shinwasorb-S 80/100
Column Size
5.1 m x 3.2 mm I.D. Glass
Column temp.
120℃ & 130℃
Carrier gas
40 mL/min N₂
Injection port temp.
200℃
Detector temp.
200℃
Detector
FID
Injection volume
2.0 μL

View detail


Graph

GC

Samples
Isopropyl iodide , Methylcyclohexane , o-xylene
Applications
Analysis of hydroxypropylcellulose (JP)
Column
ULBON HR-1
Column Size
0.53 mm I.D. x 30 m df = 3.0 µm
Column temp.
40℃ (3 min)~10℃/min~100℃~50℃/min~250℃ (3 min)
Carrier gas
52 cm/sec He
Injection port temp.
180°C
Detector temp.
280°C
Detector
FID
Injection volume
2.0 μL Split rate: 1:50

View detail


Graph

GC

Samples
Cyclohexane , N,N-dimethylaniline , Naphthalene ,
Applications
Analysis of ampicillin hydrate using Shinwasorb
Column
Silicone OV-17 1.5% Shinwasorb-S 60/80
Column Size
2.1 m x 2.6 mm I.D. Glass
Column temp.
105℃
Carrier gas
20 mL/min He(adjust so that the retention time of N,N-dimethylaniline is about 5 minutes.)
Injection port temp.
200°C
Detector temp.
200°C
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Cyclohexane , Ethyl acetate , 2-propanol ,
Applications
Analysis of lenampicillin hydrochloride using Shinwasorb
Column
Quadrol 5% Shinwasorb-S 60/80
Column Size
3.1 m x 3.2 mm I.D. Glass
Column temp.
100℃
Carrier gas
70 mL/min N₂ (Adjust so that the retention time of cyclohexane is about 1 minute.)
Injection port temp.
160°C
Detector temp.
160°C
Detector
FID
Injection volume
4.0 μL

View detail


Graph

GC

Samples
Cyclohexane , Dicyclohexyl phthalate , Etofenprox
Applications
Analysis of etofenprox using Shinwasorb
Column
Silicone OV-225 2.5% Shinwasorb-U 60/80
Column Size
1.1m x 3.2 mm I.D. Glass
Column temp.
240℃
Carrier gas
37 mL/min N₂ (Adjust so that the retention time of dicyclohexyl phthalate is about 8 minutes.)
Injection port temp.
250°C
Detector temp.
250°C
Detector
FID
Injection volume
3.0 μL

View detail


Graph

GC

Samples
Etofenprox in Cyclohexane
Applications
Analysis of etofenprox using Shinwasorb -2- ~Purity (3) Related substances~
Column
Silicone OV-225 2.5% Shinwasorb-U 60/80
Column Size
1.1m x 3.2 mm I.D. Glass
Column temp.
240℃
Carrier gas
37 mL/min N₂
Injection port temp.
250°C
Detector temp.
250°C
Detector
FID
Injection volume
3.0 μL

View detail


Graph

GC

Samples
Diethyl ether , n-Hexane , Methanol , Methyl acetate , 2-Propanol , Ethyl acetate , Tetrahydrofuran , 2-Butanol , iso-Butanol , Toluene , n-Butyl acetate , Methyl n-butyl ketone , iso-Amyl alcohol , Ethylbenzene , m-Xylene , p-Xylene , o-Xylene , Styrene monomer ,
Applications
Measurement of organic solvents using SBS-120
Column
SBS-120 12% Shincarbon-A2 80/100
Column Size
3.1 m x 3.2 mm I.D. Glass
Column temp.
90℃
Carrier gas
40 mL/min N₂
Injection port temp.
230℃
Detector temp.
230℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

LC

Samples
1,1'-Bi-2-naphthol
Applications
1,1'-Bi-2-naphthol
Column
ULTRON ES-PhCD
Column Size
150 mm L × 6.0 mm I.D.
Mobile phase
n-Hexane/Dichloromethane/CH3OH = 75/25/5
Frow rate
1.2 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
trans-Stilbene oxide
Applications
Analysis in normal phase mobile phase
Column
ULTRON ES-PhCD
Column Size
150 mm L × 6.0 mm I.D.
Mobile phase
n-Hexane/CH3OH = 99.9/0.1
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
N-(3,5-Dinitrobenzoyl)-α-Methylbenzylamine
Applications
Analysis in normal phase mobile phase
Column
ULTRON ES-PhCD
Column Size
150 mm L × 6.0 mm I.D.
Mobile phase
n-Hexane/C2H5OH = 85/15
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
Flavanone
Applications
Analysis in normal phase mobile phase
Column
ULTRON ES-PhCD
Column Size
150 mm L × 6.0 mm I.D.
Mobile phase
n-Hexane/C2H5OH = 99/1
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
Citric acid , Tartaric acid , Malic acid , Malonic acid , Succinic acid , Glycolic acid , Formic acid , Lactic acid , Acetic acid , Fumaric acid , Adipic acid , Pyroglutamic acid , Propionic acid , Acrylic acid , Pivalic acid , Methacrylic acid , Crotonic acid
Applications
Elution position of the aliphatic organic acid
Column
ULTRON PS-80H
Column Size
300 mm L × 8.0 mm I.D. + 300 mm L × 8.0 mm I.D.
Mobile phase
HClO4aq. (pH 2.1)
Frow rate
1.0 mL/min
Column temp.
60°C

View detail


Graph

LC

Samples
Sucrose , Lactose , Glucose , Xylose , Galactose , Fructose , Inositol
Applications
Sugar and alditol
Column
ULTRON PS-80P
Column Size
300 mm L × 8.0 mm I.D.
Mobile phase
H2O
Frow rate
1.0 mL/min
Column temp.
80°C
Pressure
2.0 MPa

View detail


Graph

LC

Samples
Pyridoxal , Pyridoxine , Pyridoxamine
Applications
The water-soluble vitamin (2)
Column
STR ODS-II
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
100 mM Phosphoric acid buffer(pH 2.1) + 50 mM Hexane sodium sulphonate/CH3CN = 9/1
Frow rate
1.0 mL/min
Column temp.
45°C

View detail


Graph

LC

Samples
Nicotinic acid , Nicotinic acid amide , Calcium pantothenate , Pyridoxine hydrochloride , Riboflavin phosphate , Thiamine , Folic acid , Biotin , Riboflavin
Applications
The water-soluble vitamin
Column
ULTRON VX-ODS
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
20 mM H3PO4/5 mM Sodium 1-hexanesulfonate = 91/9
Frow rate
1.0 mL/min
Column temp.
45°C

View detail


Graph

LC

Samples
Estrone , Estradiol , Estriol
Applications
Female sex hormone
Column
ULTRON VX-SIL
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
n-Hexane/C2H5OH = 90/10
Frow rate
1.0 mL/min
Column temp.
ambient

View detail


Graph

LC

Samples
Xylose , Fructose , Glucose , Mannitol , Xylobiose , Sucrose , Lactulose , Lactose , Trehalose , Xylotriose , 1-Kestose(GF2) , Raffinose , Nystose(GF3) ,
Applications
Analysis of monosaccharides, disaccharides, and oligosaccharides
Column
ULTRON AF-HILIC-CD
Column Size
100 mm L × 2.0 mm I.D.
Mobile phase
A: H2O /CH3CN = 10/90, B: H2O /CH3CN = 70/30
Frow rate
0.26 mL/min
Column temp.
40°C
Injection volume
1.0 µL
Diluent
H2O /CH3CN = 50/50

View detail


Graph

LC

Samples
Xylose , Fructose , Glucose , Mannitol , Xylobiose , Sucrose , Lactulose , Lactose , Trehalose , Xylotriose , 1-Kestose(GF2) , Raffinose , Nystose(GF3) ,
Applications
Analysis of monosaccharides, disaccharides, and oligosaccharides
Column
ULTRON AF-HILIC-CD
Column Size
100 mm L × 2.0 mm I.D.
Mobile phase
A: 20mM CH3CO2NH4 (pH6.8) /CH3CN = 10/90, B: 20mM CH3CO2NH4 (pH6.8) /CH3CN = 70/30
Frow rate
0.26 mL/min
Column temp.
40°C
Injection volume
2.5 µL
Diluent
H2O /CH3CN = 50/50

View detail


Graph

LC

Samples
Erythritol , Xylitol , Fructose , Glucose , Sorbitol , Sucrose , Inositol , Maltose , Maltitol , Lactose , Lactitol
Applications
Analysis of saccharides and sweeteners
Column
ULTRON AF-HILIC-CD
Column Size
150 mm L × 2.0 mm I.D.
Mobile phase
A: 100mM CH3CO2NH4 (pH6.8) /CH3CN = 10/90, B: 100mM CH3CO2NH4 (pH6.8) /CH3CN = 70/30
Frow rate
0.32 mL/min
Column temp.
40°C
Injection volume
1.0 µL
Diluent
H2O /CH3CN = 50/50

View detail


Graph

LC

Samples
Maleic acid , Pyruvic acid , Ascorbic acid , Gluconic acid , Adipic acid , Fumaric acid , Tartaric acid , Malic acid , Citric acid
Applications
Analysis of organic acid
Column
ULTRON AF-HILIC-CD (PLSS)
Column Size
150 mm L × 2.0 mm I.D.
Mobile phase
100mM CH3CO2NH4 (pH6.8) /CH3CN = 25/75
Frow rate
0.20 mL/min
Column temp.
40°C
Injection volume
2.0 µL
Diluent
mobile phase

View detail