Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"SER" Filtered 41 Item.

Graph

GC

Samples
Palmitic Acid Methyl Ester , Palmitoleic Acid Methyl Ester , Stearic Acid Methyl Ester , Oleoic Acid Methyl Ester , Linoleic Acid Methyl Ester , Linolenic Acid Methyl Ester , gamma-linolenic Acid Methyl Ester , Arachidonic Acid Methyl Ester , 11,14,17-Eicosadienoic Acid Methyl Ester , 7,10,13,16-Docatetranoic Acid Methyl Ester , Docosapentanoic Acid Methyl Ester
Applications
Fatty acid methyl ester in the serum
Column
Shinchrom E71 5% Shimalite 80-100 (AW)
Column Size
3.1m×3.2mm
Column temp.
230°C
Carrier gas
N2,40ml/min
Injection port temp.
260°C
Detector temp.
260°C(FID)

View detail


Graph

GC

Samples
Sorbic acid , Dehydroacetic acid , Benzoic acid , trans-Stilbene
Applications
Analysis of preservatives using Shinwasorb -1-
Column
DEGS+H3PO4 5.0+0.5% Shinwasorb-S 40/60
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
185℃
Carrier gas
50 mL/min N₂
Injection port temp.
260℃
Detector temp.
260℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
preservatives
Applications
Analysis of preservatives using Shinwasorb -2-
Column
Advance-DS+H3PO4 2+0.25% Shinwasorb-S 60/80
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
200℃
Carrier gas
50 mL/min N₂
Injection port temp.
260℃
Detector temp.
260℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

LC

Samples
Aspartic acid , Glutamic acid , Serine , Glycine , Histidine , Arginine , Threonine , Alanine , Proline , Tyrosine , Valine , Methionine , Cysteine-cysteine , Isoleucine , Leucine , Phenylalanine , Lysine
Applications
Analysis of the PTC amino acid
Column
STR ODS-II
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
A: CH3COONa (pH 6.5)/CH3CN = 93/7, B: CH3CN/H2O = 4/1
Frow rate
1.0 mL/min
Column temp.
40°C

View detail


Graph

LC

Samples
Duloxetine hydrochloride
Applications
Duloxetine hydrochloride
Column
ULTRON ES-OVM
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
20 mM KH2PO4(pH 4.6)/CH3CN = 80/20
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
Duloxetine hydrochloride
Applications
Duloxetine hydrochloride
Column
ULTRON ES-PhCD
Column Size
150 mm L × 6.0 mm I.D.
Mobile phase
20 mM KH2PO4 + H3PO4(pH 3.0)/CH3CN = 65/35
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
Duloxetine hydrochloride
Applications
Duloxetine hydrochloride
Column
ULTRON ES-OVM
Column Size
100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4(pH 4.6)/CH3CN = 80/20
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
Escitalopram oxalate
Applications
Escitalopram oxalate
Column
ULTRON ES-OVM , ULTRON ES-OVM-E
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
50 mM KH2PO4 + 0.2 N NaOH(pH 7.0)/CH3CN = 85/15
Frow rate
0.6 mL/min
Column temp.
30°C

View detail


Graph

LC

Samples
(CYS)2 , LYS , ARG , HIS , ASP , GLU , GLN , ASN , GLY , SER , ALA , THR , PRO , TYR , VAL , PHE , MET , TRP , LEU+ILE
Applications
Analysis of underivatized amino acids by LC/MS/MS
Column
ULTRON AF-HILIC-CD (PLSS)
Column Size
150 mm L × 2.0 mm I.D.
Mobile phase
A: 100 mM HCO2NH4(pH 3.0)/CH3CN = 10/90, B: 100 mM HCO2NH4(pH 3.0)/CH3CN = 70/30
Frow rate
0.36 mL/min
Column temp.
40°C
Injection volume
1.0 µL (5.0 µg/mL)

View detail


Graph

LC

Samples
Cetirizine hydrochloride
Applications
Analyses of Cetirizine hydrochloride in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 6.0)/CH3CN = 90/10
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
Mobile phase

View detail


Graph

LC

Samples
Carvedilol
Applications
Analyses of Carvedilol in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 7.0)/CH3CN = 75/25
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
ethanol

View detail


Graph

LC

Samples
Amlodipine
Applications
Analyses of Amlodipine in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 (pH 4.6)/CH3CN = 90/10
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Atomoxetine hydrochloride
Applications
Analyses of Atomoxetine hydrochloride in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 6.0)/CH3CN = 80/20
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Candesartan cilexetil
Applications
Analyses of Candesartan cilexetil in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4/CH3CN = 75/25
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Tolterodine
Applications
Analyses of Tolterodine in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 (pH 4.6)/CH3CN = 92/8
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Prilocaine hydrochloride
Applications
Analyses of Prilocaine hydrochloride in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 6.0)/CH3CN = 95/5
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Duloxetine hydrochloride
Applications
Analyses of Duloxetine hydrochloride in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 (pH 4.6)/CH3CN = 80/20
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
Mobile phase

View detail


Graph

LC

Samples
Rabeprazole sodium salt
Applications
Analyses of Rabeprazole sodium salt in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 6.0)/CH3OH = 80/20
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
ethanol

View detail


Graph

LC

Samples
Ibuprofen
Applications
Analyses of Ibuprofen in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 (pH 4.6)/CH3OH = 80/20
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
ethanol

View detail


Graph

LC

Samples
Formoterol fumarate
Applications
Analyses of Formoterol fumarate in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM K2HPO4 + 20 mM KH2PO4 (pH 7.0)/C2H5OH = 94/6
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Tolperisone hydrochloride
Applications
Analyses of Tolperisone hydrochloride in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 5.5)/C2H5OH = 95/5
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
ethanol

View detail


Graph

LC

Samples
Tadalafil
Applications
Analyses of Tadalafil in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + H3PO4 (pH 3.0)/CH3CN = 85/15
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Cetirizine hydrochloride
Applications
Analyses of Cetirizine hydrochloride in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 6.0)/CH3CN = 90/10
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
Mobile phase

View detail


Graph

LC

Samples
Carvedilol
Applications
Analyses of Carvedilol in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 7.0)/CH3CN = 75/25
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
ethanol

View detail


Graph

LC

Samples
Amlodipine
Applications
Analyses of Amlodipine in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 (pH 4.6)/CH3CN = 90/10
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Atomoxetine hydrochloride
Applications
Analyses of Atomoxetine hydrochloride in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 6.0)/CH3CN = 80/20
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Candesartan cilexetil
Applications
Analyses of Candesartan cilexetil in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4/CH3CN = 75/25
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Tolterodine
Applications
Analyses of Tolterodine in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 (pH 4.6)/CH3CN = 92/8
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Prilocaine hydrochloride
Applications
Analyses of Prilocaine hydrochloride in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 6.0)/CH3CN = 95/5
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Duloxetine hydrochloride
Applications
Analyses of Duloxetine hydrochloride in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 (pH 4.6)/CH3CN = 80/20
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
Mobile phase

View detail


Graph

LC

Samples
Rabeprazole sodium salt
Applications
Analyses of Rabeprazole sodium salt in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 6.0)/CH3OH = 80/20
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
ethanol

View detail


Graph

LC

Samples
Ibuprofen
Applications
Analyses of Ibuprofen in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 (pH 4.6)/CH3OH = 80/20
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
ethanol

View detail


Graph

LC

Samples
Formoterol fumarate
Applications
Analyses of Formoterol fumarate in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM K2HPO4 + 20 mM KH2PO4 (pH 7.0)/C2H5OH = 94/6
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Tolperisone hydrochloride
Applications
Analyses of Tolperisone hydrochloride in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 5.5)/C2H5OH = 95/5
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
ethanol

View detail


Graph

LC

Samples
Tadalafil
Applications
Analyses of Tadalafil in ULTRON ES-OVM series.(Greater analytical performance with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4 + H3PO4 (pH 3.0)/CH3CN = 85/15
Frow rate
(1)1.0 mL/min (2)0.28 mL/min
Column temp.
25°C
Injection volume
(1)2.0 µL (2)0.5 µL
Diluent
methanol

View detail


Graph

LC

Samples
Sertraline hydrochloride
Applications
Analysis of Sertraline hydrochloride
Column
ULTRON ES-OVM
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
20 mM KH2PO4 + H3PO4 (pH 3.0)/CH3CN = 85/15
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
2.0 µL
Diluent
methanol

View detail


Graph

LC

Samples
Sertraline hydrochloride
Applications
Analysis of Sertraline hydrochloride
Column
ULTRON ES-OVM
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
20 mM KH2PO4 + H3PO4 (pH 3.0)/CH3CN = 85/15
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
2.0 µL
Diluent
methanol

View detail


Graph

LC

Samples
Escitalopram oxalate
Applications
Analyses of Escitalopram oxalate in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
50 mM KH2PO4 + 0.2 N NaOH(pH 7.0)/CH3CN = 85/15
Frow rate
0.6 mL/min
Column temp.
30°C
Injection volume
(1)15.0 µL (2)0.5 µL
Diluent
Mobile phase

View detail


Graph

LC

Samples
Clopidogrel Related Compound A , Clopidogrel Related Compound B , Clopidogrel Related Compound C , Clopidogrel bisulfate
Applications
Analyses of Clopidogrel Related Compounds in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
10 mM KH2PO4/CH3CN = 75/25
Frow rate
1.0 mL/min
Column temp.
25°C
Injection volume
(1)10.0 µL (2)3.0 µL

View detail


Graph

LC

Samples
Sertraline hydrochloride , Sertraline Hydrochloride Related Compound A
Applications
Analysis of Sertraline hydrochloride
Column
ULTRON ES-CD
Column Size
250 mm L × 4.6 mm I.D.
Mobile phase
50.4mM NH4H2PO4 (pH 4.2)/CH3OH = 52/48
Frow rate
1.0 mL/min
Column temp.
30°C
Injection volume
20.0 µL
Diluent
Mobile phase

View detail


Graph

LC

Samples
Escitalopram oxalate
Applications
Analysis of Escitalopram oxalate
Column
ULTRON ES-OVM
Column Size
100 mm L × 3.0 mm I.D.
Mobile phase
50 mM KH2PO4 + 0.2 N NaOH(pH 7.0)/CH3CN = 85/15
Frow rate
0.6 mL/min
Column temp.
30°C
Injection volume
0.5 µL
Diluent
Mobile phase

View detail