Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Carbon Monoxide" Filtered 21 Item.

Graph

GC

Samples
Air , Carbon Monoxide , Methane , Carbon Dioxide
Applications
Gas (Air, CO, CH4, CO2)
Column
Activated Charcoal 60-80
Column Size
1.6m×3.2mm
Column temp.
50°C
Carrier gas
He,50ml/min
Injection port temp.
50°C
Detector temp.
50°C(TCD)

View detail


Graph

GC

Samples
Oxygen , Nitrogen , Methane , Carbon Monoxide
Applications
Gas (O2, N2, CH4, CO)
Column
Molecular Sieve 5A 60-80
Column Size
1.6m×3.2mm
Column temp.
50°C
Carrier gas
He,40ml/min
Injection port temp.
50°C
Detector temp.
50°C(TCD)

View detail


Graph

GC

Samples
Air , Carbon Monoxide , Methane , Ethane , Carbon Dioxide , Ethylene
Applications
Gas (O2, N2, CO, Methan, Ethan, CO2, Ethylene)
Column
Silica Gel 60-80
Column Size
1.6m×3.2mm
Column temp.
50°C
Carrier gas
He,60ml/min
Injection port temp.
50°C
Detector temp.
50°C(TCD)

View detail


Graph

GC

Samples
Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , Ethane
Applications
Inorganic gas and Lower hydrocarbons (3) Analysis by the 2m column
Column
Shincarbon-ST
Column Size
2m × 3mmI.D.
Column temp.
40°C (5min. hold) → 200°C (10°C/min.)
Carrier gas
He
Detector temp.
200°C
Injection volume
0.5mL

View detail


Graph

GC

Samples
Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , Ethane
Applications
Inorganic gas and Lower hydrocarbons (4) Analysis by the 4m column
Column
Shincarbon-ST
Column Size
4m (2m×2) × 3mmI.D.
Column temp.
40°C (7min. hold) → 200°C (10°C/min.)
Carrier gas
He
Detector temp.
200°C
Injection volume
0.5mL

View detail


Graph

GC

Samples
Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , Ethane
Applications
Inorganic gas and Lower hydrocarbons (5) Analysis by the 6m column
Column
Shincarbon-ST
Column Size
6m (2m×3)) × 3mmI.D.
Column temp.
40°C (12min. hold) → 200°C (10°C/min.)
Carrier gas
He
Detector temp.
200°C
Injection volume
0.5mL

View detail


Graph

GC

Samples
Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , Ethane
Applications
Inorganic gas and Lower hydrocarbons (6) Analysis by the 8m column
Column
Shincarbon-ST
Column Size
8m (2m×4) × 3mmI.D.
Column temp.
40°C (20min. hold) → 200°C (10°C/min.)
Carrier gas
He
Detector temp.
200°C
Injection volume
0.5mL

View detail


Graph

GC

Samples
Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , Ethane
Applications
Inorganic gas and Lower hydrocarbons (7) Analysis by the 8m column
Column
Micropacked-ST
Column Size
2m × 1mmI.D.
Column temp.
35°C (2min. hold) → 200°C (25°C/min.)
Carrier gas
He,200kPa
Detector temp.
200°C
Injection volume
0.05mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide
Applications
Inorganic gas and Lower hydrocarbons (8) Analysis by the 8m column
Column
Micropacked-ST
Column Size
2m × 1mmI.D.
Column temp.
80°C
Carrier gas
Ar,200kPa
Detector temp.
80°C
Injection volume
0.05mL

View detail


Graph

GC

Samples
Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide
Applications
Inorganic gas and Lower hydrocarbons (9) Analysis by the 8m column
Column
Micropacked-ST
Column Size
3m × 1mmI.D.
Column temp.
35°C (3.5min. hold) → 80°C (10°C/min.)
Carrier gas
He,300kPa
Detector temp.
80°C
Injection volume
0.05mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane
Applications
Inorganic gas and Lower hydrocarbons (10) Analysis by the 8m column
Column
Micropacked-MS
Column Size
2m × 1mmI.D.
Column temp.
80°C
Carrier gas
He,200kPa
Detector temp.
80°C
Injection volume
0.05mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane
Applications
Inorganic gas and Lower hydrocarbons (11) Analysis by the 8m column
Column
Micropacked-MS
Column Size
2m × 1mmI.D.
Column temp.
80°C
Carrier gas
Ar,200kPa
Detector temp.
80°C
Injection volume
0.05mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide
Applications
Inorganic gases analysis including hydrogen by Shincarbon-ST column 2m
Column
Shincarbon-ST 50/80 mesh
Column Size
2.0 m x 3.0 mm I.D. Stainless
Column temp.
40°C (3 min. hold) - 200°C (20°C/min.)
Carrier gas
50 mL/min Ar
Injection port temp.
200°C
Detector temp.
200°C
Detector
TCD
Injection volume
1.0 mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide
Applications
Inorganic gases analysis including hydrogen by Shincarbon-ST column 6m
Column
Shincarbon-ST 50/80 mesh
Column Size
6.0 m x 3.0 mm I.D. Stainless
Column temp.
40°C (8 min. hold) - 200°C (20°C/min.)
Carrier gas
50 mL/min Ar
Injection port temp.
200°C
Detector temp.
200°C
Detector
TCD
Injection volume
1.0 mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane
Applications
Inorganic gases analysis including hydrogen by Molecular Sieve 5A column
Column
Molecular Sieve 5A 60/80 mesh
Column Size
2.0 m x 3.0 mm I.D. Stainless
Column temp.
60°C
Carrier gas
30 mL/min Ar
Injection port temp.
60°C
Detector temp.
60°C
Detector
TCD
Injection volume
1.0 mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane
Applications
Inorganic gases analysis including hydrogen by Molecular Sieve 13X column
Column
Molecular Sieve 13X 60/80 mesh
Column Size
2.0 m x 3.0 mm I.D. Stainless
Column temp.
60°C
Carrier gas
30 mL/min Ar
Injection port temp.
60°C
Detector temp.
60°C
Detector
TCD
Injection volume
1.0 mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide
Applications
Inorganic gases analysis including hydrogen by Activated Charcoal column
Column
Activated Charcoal 60/80 mesh
Column Size
2.0 m x 3.0 mm I.D. Stainless
Column temp.
60°C
Carrier gas
30 mL/min Ar
Injection port temp.
60°C
Detector temp.
60°C
Detector
TCD
Injection volume
1.0 mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide
Applications
Inorganic gases analysis including hydrogen by Silica Gel column
Column
Silica Gel 60/80 mesh
Column Size
2.0 m x 3.0 mm I.D. Stainless
Column temp.
60°C
Carrier gas
30 mL/min Ar
Injection port temp.
60°C
Detector temp.
60°C
Detector
TCD
Injection volume
1.0 mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide
Applications
Inorganic gases analysis including hydrogen by Sunpak-A column
Column
Sunpak-A 50/80 mesh
Column Size
2.0 m x 3.0 mm I.D. Stainless
Column temp.
40°C
Carrier gas
30 mL/min Ar
Injection port temp.
60°C
Detector temp.
60°C
Detector
TCD
Injection volume
1.0 mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide
Applications
Inorganic gases analysis including hydrogen by Micropacked-ST column
Column
Micropacked-ST
Column Size
2.0 m x 1.0 mm I.D. Stainless
Column temp.
80°C
Carrier gas
200 kPa Ar
Injection port temp.
80°C
Detector temp.
80°C
Detector
TCD
Injection volume
0.05 mL

View detail


Graph

GC

Samples
Hydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane
Applications
Inorganic gases analysis including hydrogen by Micropacked-MS column
Column
Micropacked-MS
Column Size
2.0 m x 1.0 mm I.D. Stainless
Column temp.
80°C
Carrier gas
200 kPa Ar
Injection port temp.
80°C
Detector temp.
80°C
Detector
TCD
Injection volume
0.05 mL

View detail