Search result
"Cyclohexane" Filtered 9 Item.
GC
- Samples
- Mixture of 22 organic solvents
- Applications
- Measurement of organic solvents using Shinwasorb -2-
- Column
- PEG1500 12.5% Shinwasorb-U 40/60
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 60~120℃ (4℃/min)
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Isopropyl iodide , Methylcyclohexane , o-xylene
- Applications
- Analysis of hydroxypropylcellulose (JP)
- Column
- ULBON HR-1
- Column Size
- 0.53 mm I.D. x 30 m df = 3.0 µm
- Column temp.
- 40℃ (3 min)~10℃/min~100℃~50℃/min~250℃ (3 min)
- Carrier gas
- 52 cm/sec He
- Injection port temp.
- 180°C
- Detector temp.
- 280°C
- Detector
- FID
- Injection volume
- 2.0 μL Split rate: 1:50
View detail
GC
- Samples
- Cyclohexane , N,N-dimethylaniline , Naphthalene ,
- Applications
- Analysis of ampicillin hydrate using Shinwasorb
- Column
- Silicone OV-17 1.5% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 2.6 mm I.D. Glass
- Column temp.
- 105℃
- Carrier gas
- 20 mL/min He(adjust so that the retention time of N,N-dimethylaniline is about 5 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Cyclohexane , Ethyl acetate , 2-propanol ,
- Applications
- Analysis of lenampicillin hydrochloride using Shinwasorb
- Column
- Quadrol 5% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 100℃
- Carrier gas
- 70 mL/min N₂ (Adjust so that the retention time of cyclohexane is about 1 minute.)
- Injection port temp.
- 160°C
- Detector temp.
- 160°C
- Detector
- FID
- Injection volume
- 4.0 μL
View detail
GC
- Samples
- Cyclohexane , Dicyclohexyl phthalate , Etofenprox
- Applications
- Analysis of etofenprox using Shinwasorb
- Column
- Silicone OV-225 2.5% Shinwasorb-U 60/80
- Column Size
- 1.1m x 3.2 mm I.D. Glass
- Column temp.
- 240℃
- Carrier gas
- 37 mL/min N₂ (Adjust so that the retention time of dicyclohexyl phthalate is about 8 minutes.)
- Injection port temp.
- 250°C
- Detector temp.
- 250°C
- Detector
- FID
- Injection volume
- 3.0 μL
View detail
LC
- Samples
- Sucrose , Lactose , Glucose , Xylose , Galactose , Fructose , Inositol
- Applications
- Sugar and alditol
- Column
- ULTRON PS-80P
- Column Size
- 300 mm L × 8.0 mm I.D.
- Mobile phase
- H2O
- Frow rate
- 1.0 mL/min
- Column temp.
- 80°C
- Pressure
- 2.0 MPa
View detail
LC
- Samples
- Erythritol , Xylitol , Fructose , Glucose , Sorbitol , Sucrose , Inositol , Maltose , Maltitol , Lactose , Lactitol
- Applications
- Analysis of saccharides and sweeteners
- Column
- ULTRON AF-HILIC-CD
- Column Size
- 150 mm L × 2.0 mm I.D.
- Mobile phase
- A: 100mM CH3CO2NH4 (pH6.8) /CH3CN = 10/90, B: 100mM CH3CO2NH4 (pH6.8) /CH3CN = 70/30
- Frow rate
- 0.32 mL/min
- Column temp.
- 40°C
- Injection volume
- 1.0 µL
- Diluent
- H2O /CH3CN = 50/50
View detail