Samples
α-Pinene , β-Pinene , Limonene , Octyl Aldehyde , Nonyl Aldehyde , Citronellal , Decyl Aldehyde , Linalool , Linalyl Acetate , Isobornyl Acetate(Citronellol) , Menthol , Benzyl Acetate , Perillaldehyde , Geraniol , α-Ionone , Rose-P , C12-Alcohol , Anisaldehyde , Methyl Cinnamate , Ethyl Cinnamate , Eugenol , Heliotropin , DEP , Vanillin , Benzyl Benzoate , Benzyl Salicylate
Applications
The mixed sample of perfume component
Column
Thermon-3000 5% Chromosorb W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
80°C→250°C(6°C/min)
Carrier gas
N2,60ml/min
Injection port temp.
290°C
Detector temp.
280°C(FID)

View detail


Graph

LC

Samples
Trimipramine maleate
Applications
Analysis of the antidepressive drug
Column
ULTRON ES-OVM
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
20 mM KH2PO4 (pH 3.0)/C2H5OH = 100/30
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
Disopyramide phosphate
Applications
Disopyramide phosphate
Column
ULTRON ES-OVM
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4 (pH 6.0)/C2H5OH = 90/10
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
Duloxetine hydrochloride
Applications
Duloxetine hydrochloride
Column
ULTRON ES-OVM
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
20 mM KH2PO4(pH 4.6)/CH3CN = 80/20
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
Duloxetine hydrochloride
Applications
Duloxetine hydrochloride
Column
ULTRON ES-PhCD
Column Size
150 mm L × 6.0 mm I.D.
Mobile phase
20 mM KH2PO4 + H3PO4(pH 3.0)/CH3CN = 65/35
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
Bupropion hydrochloride
Applications
Bupropion hydrochloride
Column
ULTRON ES-OVM
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
20 mM KH2PO4 + 20 mM K2HPO4(pH 6.0)/C2H5OH = 90/10
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
Duloxetine hydrochloride
Applications
Duloxetine hydrochloride
Column
ULTRON ES-OVM
Column Size
100 mm L × 3.0 mm I.D.
Mobile phase
20 mM KH2PO4(pH 4.6)/CH3CN = 80/20
Frow rate
1.0 mL/min
Column temp.
25°C

View detail


Graph

LC

Samples
Escitalopram oxalate
Applications
Escitalopram oxalate
Column
ULTRON ES-OVM , ULTRON ES-OVM-E
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
50 mM KH2PO4 + 0.2 N NaOH(pH 7.0)/CH3CN = 85/15
Frow rate
0.6 mL/min
Column temp.
30°C

View detail


Graph

LC

Samples
Escitalopram oxalate
Applications
Analyses of Escitalopram oxalate in ULTRON ES-OVM series.(Faster analyses with 3µm particles)
Column
ULTRON ES-OVM
Column Size
(1)150 mm L × 4.6 mm I.D. (2)100 mm L × 3.0 mm I.D.
Mobile phase
50 mM KH2PO4 + 0.2 N NaOH(pH 7.0)/CH3CN = 85/15
Frow rate
0.6 mL/min
Column temp.
30°C
Injection volume
(1)15.0 µL (2)0.5 µL
Diluent
mobile phase

View detail


Graph

LC

Samples
Escitalopram oxalate
Applications
Analysis of Escitalopram oxalate
Column
ULTRON ES-OVM
Column Size
100 mm L × 3.0 mm I.D.
Mobile phase
50 mM KH2PO4 + 0.2 N NaOH(pH 7.0)/CH3CN = 85/15
Frow rate
0.6 mL/min
Column temp.
30°C
Injection volume
0.5 µL
Diluent
mobile phase

View detail