Search result
"Isobutyl Alcohol" Filtered 7 Item.
GC
- Samples
- Methyl Alcohol , Ethyl Alcohol , Isopropyl Alcohol , tert-Butyl Alcohol , n-Propyl Alcohol , sec-Butyl Alcohol , Isobutyl Alcohol , n-Butyl Alcohol , Isoamyl Alcohol , n-Amyl Alcohol
- Applications
- Lower alcohol (2) (each 500ppm)
- Column
- FAL-M 10% Shimalite TPA 60-80
- Column Size
- 2.1m×3.2mm
- Column temp.
- 90°C
- Carrier gas
- N2,40ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Methyl Alcohol , Ethyl Alcohol , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Methyl Isobutyl Ketone , Toluene , Butyl Acetate , Cellosolve , Ethylbenzene , m-Xylene , p-Xylene , o-Xylene , Cyclohexanone
- Applications
- Organic solvents (2)
- Column
- SBS-1 10% Shimalite TPA 60-80
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,40ml/min
- Injection port temp.
- 230°C
- Detector temp.
- 230°C(FID)
View detail
GC
- Samples
- n-Hexane , Methyl Alcohol , Acetone , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Trichloroethylene , Isobutyl Alcohol , Isobutyl Acetate , Toluene , n-Butyl Acetate , Isoamyl Alcohol , Ethylbenzene , m-Xylene , o-Xylene , n-Propylbenzene , Cyclohexanone
- Applications
- Organic solvent in the air (ppm level)
- Column
- SBS-100 10% Shimalite TPA 60-80
- Column Size
- 3.1m×3.2mm
- Column temp.
- 110°C
- Carrier gas
- N2,30ml/min
- Injection port temp.
- 200°C
- Detector temp.
- 200°C(FID)
View detail
GC
- Samples
- Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Organic solvent in work environment (2)
- Column
- SBS-200 20% Shimalite W 100-120 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Organic solvents of the atmosphere (ppm level)
- Column
- SBS-200 20% Shimalite W 100-120 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Methyl Alcohol , Acetaldehyde , Ethyl Alcohol , n-Propyl Alcohol , Isobutyl Alcohol , Isoamyl Alcohol
- Applications
- Aldehyde in the wine and Lower alcohol
- Column
- Thermon-1000 5% Sunpak-A
- Column Size
- 2.1m×3.2mm
- Column temp.
- 140°C→180°C(6°C/min)
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- Mixture of 22 organic solvents
- Applications
- Measurement of organic solvents using Shinwasorb -2-
- Column
- PEG1500 12.5% Shinwasorb-U 40/60
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 60~120℃ (4℃/min)
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail