Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Limonene" Filtered 8 Item.

Graph

GC

Samples
α-Pinene , β-Pinene , Limonene , Octyl Aldehyde , Nonyl Aldehyde , Citronellal , Decyl Aldehyde , Linalool , Linalyl Acetate , Isobornyl Acetate(Citronellol) , Menthol , Benzyl Acetate , Perillaldehyde , Geraniol , α-Ionone , Rose-P , C12-Alcohol , Anisaldehyde , Methyl Cinnamate , Ethyl Cinnamate , Eugenol , Heliotropin , DEP , Vanillin , Benzyl Benzoate , Benzyl Salicylate
Applications
The mixed sample of perfume component
Column
Thermon-3000 5% Chromosorb W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
80°C→250°C(6°C/min)
Carrier gas
N2,60ml/min
Injection port temp.
290°C
Detector temp.
280°C(FID)

View detail


Graph

GC

Samples
α-Pinene , β-Pinene , Limonene , Linalool , Linalyl Acetate , Benzyl Acetate , Phenethyl Alcohol
Applications
perfume (1)
Column
ULBON HR-Thermon-600T
Column Size
50m×0.25mm
Column temp.
70°C→230°C(4°C/min)
Carrier gas
He,1.1ml/min
Detector temp.
250°C(FID)

View detail


Graph

GC

Samples
β-Pinene , Limonene , Linalool , Linalyl Acetate , Benzyl Acetate , α-Ionene , Phenethyl Alcohol , Lauryl Alcohol , Eugenol , Diethyl Phthalate , Vanillin , Benzyl Salicylate
Applications
perfume (2)
Column
ULBON HR-Thermon-600T
Column Size
50m×0.25mm
Column temp.
70°C→230°C(4°C/min)
Carrier gas
He,1.1ml/min
Detector temp.
250°C(FID)

View detail


Graph

GC

Samples
α-Pinene , Limonene , Isobornyl Acetate , α-Ionone
Applications
Analysis of the fragrance of a flower using NeedlEx (for organic solvent) 3
Column
ULBON HR-1
Column Size
0.32mmI.D. × 30m (0.26um)
Column temp.
50°C→200°C(5°C/min)
Carrier gas
He,2.4ml/min
Detector temp.
250°C(FID)
Injection volume
-

View detail


Graph

GC

Samples
Myrcene , Limonene
Applications
Analysis of the fragrance of a flower using NeedlEx (for organic solvent) 7
Column
ULBON HR-1
Column Size
0.32mmI.D. × 30m (0.26um)
Column temp.
50°C→200°C(5°C/min)
Carrier gas
He,2.4ml/min
Detector temp.
250°C(FID)
Injection volume
-

View detail


Graph

GC

Samples
Fragrance
Applications
Measurements of fragrance using Shinwasorb
Column
Thermon-3000 5% Shinwasorb-S 80/100
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
80~260℃(6℃/min)
Carrier gas
50 mL/min N₂
Injection port temp.
280℃
Detector temp.
280℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
200 ppm in hexane
Applications
Measurements of eucalyptus oil using Shinwasorb
Column
Thermon-3000 5% Shinwasorb-S 80/100
Column Size
5.1 m x 3.2 mm I.D. Glass
Column temp.
120℃ & 130℃
Carrier gas
40 mL/min N₂
Injection port temp.
200℃
Detector temp.
200℃
Detector
FID
Injection volume
2.0 μL

View detail


Graph

GC

Samples
Limonene , Cineole
Applications
Analysis of eucalyptus oil using Shinwasorb
Column
Thermon-3000 5% Shinwasorb-S 80/100
Column Size
5.1 m x 3.2 mm I.D. Glass
Column temp.
130°C
Carrier gas
N2,35ml/min
Injection port temp.
200°C
Detector temp.
200°C
Detector
FID

View detail