GCSamplesOxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , EthaneApplicationsInorganic gas and Lower hydrocarbons (3) Analysis by the 2m columnColumnShincarbon-STColumn Size2m × 3mmI.D.Column temp.40°C (5min. hold) → 200°C (10°C/min.)Carrier gasHeDetector temp.200°CInjection volume0.5mL View detail
GCSamplesOxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , EthaneApplicationsInorganic gas and Lower hydrocarbons (4) Analysis by the 4m columnColumnShincarbon-STColumn Size4m (2m×2) × 3mmI.D.Column temp.40°C (7min. hold) → 200°C (10°C/min.)Carrier gasHeDetector temp.200°CInjection volume0.5mL View detail
GCSamplesOxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , EthaneApplicationsInorganic gas and Lower hydrocarbons (5) Analysis by the 6m columnColumnShincarbon-STColumn Size6m (2m×3)) × 3mmI.D.Column temp.40°C (12min. hold) → 200°C (10°C/min.)Carrier gasHeDetector temp.200°CInjection volume0.5mL View detail
GCSamplesOxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , EthaneApplicationsInorganic gas and Lower hydrocarbons (6) Analysis by the 8m columnColumnShincarbon-STColumn Size8m (2m×4) × 3mmI.D.Column temp.40°C (20min. hold) → 200°C (10°C/min.)Carrier gasHeDetector temp.200°CInjection volume0.5mL View detail
GCSamplesOxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , EthaneApplicationsInorganic gas and Lower hydrocarbons (7) Analysis by the 8m columnColumnMicropacked-STColumn Size2m × 1mmI.D.Column temp.35°C (2min. hold) → 200°C (25°C/min.)Carrier gasHe,200kPaDetector temp.200°CInjection volume0.05mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon DioxideApplicationsInorganic gas and Lower hydrocarbons (8) Analysis by the 8m columnColumnMicropacked-STColumn Size2m × 1mmI.D.Column temp.80°CCarrier gasAr,200kPaDetector temp.80°CInjection volume0.05mL View detail
GCSamplesOxigen , Nitrogen , Carbon Monoxide , Methane , Carbon DioxideApplicationsInorganic gas and Lower hydrocarbons (9) Analysis by the 8m columnColumnMicropacked-STColumn Size3m × 1mmI.D.Column temp.35°C (3.5min. hold) → 80°C (10°C/min.)Carrier gasHe,300kPaDetector temp.80°CInjection volume0.05mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , MethaneApplicationsInorganic gas and Lower hydrocarbons (10) Analysis by the 8m columnColumnMicropacked-MSColumn Size2m × 1mmI.D.Column temp.80°CCarrier gasHe,200kPaDetector temp.80°CInjection volume0.05mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , MethaneApplicationsInorganic gas and Lower hydrocarbons (11) Analysis by the 8m columnColumnMicropacked-MSColumn Size2m × 1mmI.D.Column temp.80°CCarrier gasAr,200kPaDetector temp.80°CInjection volume0.05mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon DioxideApplicationsInorganic gases analysis including hydrogen by Shincarbon-ST column 2mColumnShincarbon-ST 50/80 meshColumn Size2.0 m x 3.0 mm I.D. StainlessColumn temp.40°C (3 min. hold) - 200°C (20°C/min.)Carrier gas50 mL/min ArInjection port temp.200°CDetector temp.200°CDetectorTCDInjection volume1.0 mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon DioxideApplicationsInorganic gases analysis including hydrogen by Shincarbon-ST column 6mColumnShincarbon-ST 50/80 meshColumn Size6.0 m x 3.0 mm I.D. StainlessColumn temp.40°C (8 min. hold) - 200°C (20°C/min.)Carrier gas50 mL/min ArInjection port temp.200°CDetector temp.200°CDetectorTCDInjection volume1.0 mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , MethaneApplicationsInorganic gases analysis including hydrogen by Molecular Sieve 5A columnColumnMolecular Sieve 5A 60/80 meshColumn Size2.0 m x 3.0 mm I.D. StainlessColumn temp.60°CCarrier gas30 mL/min ArInjection port temp.60°CDetector temp.60°CDetectorTCDInjection volume1.0 mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , MethaneApplicationsInorganic gases analysis including hydrogen by Molecular Sieve 13X columnColumnMolecular Sieve 13X 60/80 meshColumn Size2.0 m x 3.0 mm I.D. StainlessColumn temp.60°CCarrier gas30 mL/min ArInjection port temp.60°CDetector temp.60°CDetectorTCDInjection volume1.0 mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon DioxideApplicationsInorganic gases analysis including hydrogen by Activated Charcoal columnColumnActivated Charcoal 60/80 meshColumn Size2.0 m x 3.0 mm I.D. StainlessColumn temp.60°CCarrier gas30 mL/min ArInjection port temp.60°CDetector temp.60°CDetectorTCDInjection volume1.0 mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon DioxideApplicationsInorganic gases analysis including hydrogen by Silica Gel columnColumnSilica Gel 60/80 meshColumn Size2.0 m x 3.0 mm I.D. StainlessColumn temp.60°CCarrier gas30 mL/min ArInjection port temp.60°CDetector temp.60°CDetectorTCDInjection volume1.0 mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon DioxideApplicationsInorganic gases analysis including hydrogen by Sunpak-A columnColumnSunpak-A 50/80 meshColumn Size2.0 m x 3.0 mm I.D. StainlessColumn temp.40°CCarrier gas30 mL/min ArInjection port temp.60°CDetector temp.60°CDetectorTCDInjection volume1.0 mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon DioxideApplicationsInorganic gases analysis including hydrogen by Micropacked-ST columnColumnMicropacked-STColumn Size2.0 m x 1.0 mm I.D. StainlessColumn temp.80°CCarrier gas200 kPa ArInjection port temp.80°CDetector temp.80°CDetectorTCDInjection volume0.05 mL View detail
GCSamplesHydrogen , Oxigen , Nitrogen , Carbon Monoxide , MethaneApplicationsInorganic gases analysis including hydrogen by Micropacked-MS columnColumnMicropacked-MSColumn Size2.0 m x 1.0 mm I.D. StainlessColumn temp.80°CCarrier gas200 kPa ArInjection port temp.80°CDetector temp.80°CDetectorTCDInjection volume0.05 mL View detail
GCSamplesOxigen , NitrogenApplicationsOxygen purity test (JP) by Molecular Sieve 5A columnColumnMolecular Sieve 5A 45/60 meshColumn Size3.1 m x 3.2 mm I.D. GlassColumn temp.50°CCarrier gas30 mL/min HeInjection port temp.80°CDetector temp.80°CDetectorTCDInjection volume1.0 mL View detail