Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Parathion" Filtered 4 Item.

Graph

GC

Samples
DDVP , Methyldimethone , Methylparathion , Ethylparathion , EPN
Applications
Organic phosphorus system pesticides (3)
Column
Silicone DC 200 5% Chromosorb HP 80-100
Column Size
2.1m×3.2mm
Column temp.
200°C→230°C(4°C/min)
Carrier gas
N2,50ml/min
Injection port temp.
270°C
Detector temp.
270°C(FPD)

View detail


Graph

GC

Samples
α-BHC , γ-BHC , β-BHC , δ-BHC , Parathion , PP´-DDE , Endrin , PP´-DDD , PP´-DDT , EPN
Applications
Chlorinated pesticide in green tea
Column
Silicone OV-17 2% Chromosorb W 80-100 (AW-DMCS)
Column Size
2.1m×3.2mm
Column temp.
200°C
Carrier gas
N2,60ml/min
Injection port temp.
270°C
Detector temp.
270°C(ECD)

View detail


Graph

GC

Samples
DDVP , Methyldimethone , Methylparathion , Ethylparathion , EPN
Applications
Organic phosphorus system pesticides (1)
Column
ULBON HR-1
Column Size
15m×0.53mm(1.0μm)
Column temp.
150°C→220°C(6°C/min)
Carrier gas
He,10.7ml/min
Detector temp.
250°C(FID)
Injection volume
0.8μl

View detail


Graph

GC

Samples
Dichlorvos (DDVP) , Methyldemeton , Methyl parathion , Parathion , EPN
Applications
Measurement of organophosphorus compounds using Shinwasorb
Column
Silicone OV-17 1% Shinwasorb-S 60/80
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
180-250℃ (8℃/min)
Carrier gas
50 mL/min N₂
Injection port temp.
260℃
Detector temp.
260℃
Detector
FPD
Injection volume
1.0 μL

View detail