"Phenol" Filtered 18 Item.
GC
- Samples
- 2,6-Xylenol , o-Cresol , Phenol , 2,4-Xylenol , p-Cresol , m-Cresol , 3,5-Xylenol , 3,4-Xylenol
- Applications
- Cresol isomer and Xylenol
- Column
- FAP-S Chromosorb W 60-80 (AW)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 160°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 250°C
- Detector temp.
- 250°C(FID)
View detail
GC
- Samples
- Phenetole , o-Cresol , Phenol , p-Cresol , m-Cresol , 3,4-Xylenol
- Applications
- Cresol isomer and Phenol (each 1000ppm)
- Column
- Lanoline(Denatured) 10% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 1.6m×3.2mm
- Column temp.
- 180°C
- Carrier gas
- N2,55ml/min
- Injection port temp.
- 250°C
- Detector temp.
- 250°C(FID)
View detail
GC
- Samples
- Catechol , Hydroquinone , Resorcinol
- Applications
- Dihydric phenol in water
- Column
- Thermon-3000 1% Shimalite TPA 60-80
- Column Size
- 0.5m×3.2mm
- Column temp.
- 160°C
- Carrier gas
- N2,60ml/min
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- 2,6-Xylenol , p-Cresol , m-Cresol , 2,4,6-Trimethylphenol , 2,4-Xylenol , 2,5-Xylenol , 2,3,6-Trimethylphenol , 2,3-Xylenol , p-Ethylphenol , m-Ethylphenol , 3,5-Xylenol , 3,4-Xylenol
- Applications
- Analysis of the impurity in the 3,5- xylenol ( 10% benzene solution )
- Column
- ULBON ALPhen
- Column Size
- 50m×0.20mm
- Column temp.
- 130°C
- Carrier gas
- N2,0.39ml/min
- Detector temp.
- 250°C(FID)
- Injection volume
- 0.5μm
View detail
GC
- Samples
- Phenol , 2,6-Xylenol , o-Cresol , p-Cresol , m-Cresol , o-Ethylphenol , 2,4,6-Trimethylphenol , 2,4-Xylenol , 2,5-Xylenol , 2,3,6-Trimethylphenol , 2,3-Xylenol , p-Ethylphenol , m-Ethylphenol , 3,5-Xylenol , 3,4-Xylenol , 2,3,5-Trimethylphenol
- Applications
- Alkylphenol isomer
- Column
- ULBON ALPhen (WCOT)
- Column Size
- 50m×0.20mm
- Column temp.
- 130°C
- Carrier gas
- N2,0.39ml/min
- Detector temp.
- 250°C(FID)
- Injection volume
- 0.5μl
View detail
GC
- Samples
- 2,6-Xylenol , o-Cresol , Phenol , 2,4-Xylenol , p-Cresol , m-Cresol , 3,5-Xylenol , 3,4-Xylenol
- Applications
- Measurements of cresol and xylenol isomers using Shinwasorb
- Column
- FAP-S Shinwasorb-U 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 160℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 250℃
- Detector temp.
- 250℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
LC
- Samples
- Salbutamol
- Applications
- Bronchodilator agent
- Column
- ULTRON ES-PEPSIN
- Column Size
- 150 mm L × 6.0 mm I.D.
- Mobile phase
- 20 mM KH2PO4 (pH 5.0)/C2H5OH = 95/5
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
- Injection volume
- 1.0 µL (0.25 mg/mL)
View detail
LC
- Samples
- Acetaminophen , Caffeine , Riboflavin , Phenol , Potassium guaiacol-4-sulfonate
- Applications
- The component of the cold remedy (2)
- Column
- STR ODS-II
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- H2O/CH3CN/50 mM Tetrabutylammonium = 15/2/1 (Adjusted to pH 6 with Phosphoric acid)
- Frow rate
- 1.0 mL/min
- Column temp.
- 50°C
View detail
LC
- Samples
- Salicylic acid , Diphenhydramine , Methyl salicylate , α-Camphor , Thymol
- Applications
- The component of the anti-inflammatory agent
- Column
- STR ODS-II
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 10 mM Phosphoric acid buffer(pH 2.6) + 20 mM Heptane sodium sulphonate/CH3OH/CH3CN = 3/2/2
- Frow rate
- 1.0 mL/min
- Column temp.
- 45°C
View detail
LC
- Samples
- Prostaglandin , 2,4,5-Trihydroxybutyrophenone , Nordihydroguaiaretic acid , Butyl hydroxy anisole , Octyl gallate , 2,6-Di-tert-butyl-4-hydroxymethylphenol , Lauryl gallate , 2,6-Di-t-butyl 4-methylphenol
- Applications
- The phenolic system antioxidant (Added to commercial edible oil)
- Column
- STR ODS-II
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- A: 10 mM Phosphoric acid buffer(pH 2.6), B: CH3CN
- Frow rate
- 1.0 mL/min
- Column temp.
- 40°C
View detail
LC
- Samples
- p-Hydroxybenzoic acid , m-Hydroxybenzoic acid , Phenol , Acetylsalicylic acid , Benzoic acid , Salicylic acid
- Applications
- Acidic compounds
- Column
- ULTRON VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 10 mM (NH4)3PO4(pH 2.5)/CH3CN = 80/20
- Frow rate
- 1.0 mL/min
- Column temp.
- 30°C
View detail
LC
- Samples
- Pyridine , Phenol
- Applications
- Pyridine, Phenol test
- Column
- ULTRON VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- CH3CN/H2O = 30/70
- Frow rate
- 1.0 mL/min
- Column temp.
- 30°C
View detail
LC
- Samples
- Tolterodine
- Applications
- Analysis of Tolterodine
- Column
- ULTRON ES-OVM
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM KH2PO4 (pH 4.6)/CH3CN = 92/8
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
- Injection volume
- 2.0 µL
- Diluent
- methanol
View detail
LC
- Samples
- Tolterodine
- Applications
- Analysis of Tolterodine
- Column
- ULTRON ES-OVM
- Column Size
- 100 mm L × 3.0 mm I.D.
- Mobile phase
- 20 mM KH2PO4 (pH 4.6)/CH3CN = 92/8
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
- Injection volume
- 0.5 µL
- Diluent
- methanol
View detail
LC
- Samples
- Tolterodine
- Applications
- Analysis of Tolterodine
- Column
- ULTRON ES-OVM
- Column Size
- 100 mm L × 3.0 mm I.D.
- Mobile phase
- 20 mM KH2PO4 (pH 4.6)/CH3CN = 92/8
- Frow rate
- 0.28 mL/min
- Column temp.
- 25°C
- Injection volume
- 0.5 µL
- Diluent
- methanol
View detail