Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Raffinose" Filtered 4 Item.

Graph

GC

Samples
Sucrose , Maltose , Lactose , Raffinose
Applications
Sugar
Column
ULBON HR-1701
Column Size
25m×0.25mm(0.25μm)
Column temp.
180°C→280°C(4°C/min)
Carrier gas
He,0.49ml/min
Detector temp.
300°C(FID)
Injection volume
1μl

View detail


Graph

LC

Samples
Stachyose , Raffinose , Glucose
Applications
Separation of stachyose and raffinose
Column
ULTRON PS-80N
Column Size
300 mm L × 8.0 mm I.D.
Mobile phase
H2O
Frow rate
1.0 mL/min
Column temp.
60°C
Pressure
2.5 MPa
Injection volume
10 µL (2 mg/mL)

View detail


Graph

LC

Samples
Xylose , Fructose , Glucose , Mannitol , Xylobiose , Sucrose , Lactulose , Lactose , Trehalose , Xylotriose , 1-Kestose(GF2) , Raffinose , Nystose(GF3) ,
Applications
Analysis of monosaccharides, disaccharides, and oligosaccharides
Column
ULTRON AF-HILIC-CD
Column Size
100 mm L × 2.0 mm I.D.
Mobile phase
A: H2O /CH3CN = 10/90, B: H2O /CH3CN = 70/30
Frow rate
0.26 mL/min
Column temp.
40°C
Injection volume
1.0 µL
Diluent
H2O /CH3CN = 50/50

View detail


Graph

LC

Samples
Xylose , Fructose , Glucose , Mannitol , Xylobiose , Sucrose , Lactulose , Lactose , Trehalose , Xylotriose , 1-Kestose(GF2) , Raffinose , Nystose(GF3) ,
Applications
Analysis of monosaccharides, disaccharides, and oligosaccharides
Column
ULTRON AF-HILIC-CD
Column Size
100 mm L × 2.0 mm I.D.
Mobile phase
A: 20mM CH3CO2NH4 (pH6.8) /CH3CN = 10/90, B: 20mM CH3CO2NH4 (pH6.8) /CH3CN = 70/30
Frow rate
0.26 mL/min
Column temp.
40°C
Injection volume
2.5 µL
Diluent
H2O /CH3CN = 50/50

View detail