Search result
"Shinwsasorb" Filtered 8 Item.
GC
- Samples
- Chloroform , Fenitrothion , Fluoranthene
- Applications
- Analysis of fenitrothion using Shinwasorb
- Column
- Polyphenyl Ether (5 rings) 1.5% Shinwasorb-S 100/120
- Column Size
- 1.1 m x 3.2 mm I.D. Glass
- Column temp.
- 195℃
- Carrier gas
- 55 mL/min N₂
- Injection port temp.
- 230℃
- Detector temp.
- 230℃
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Carbonyl sulfide , Hydrogen sulfide , Carbon disulfide , Methyl mercaptan , Ethyl mercaptan , Dimethyl sulfide , Dimethyl disulfide
- Applications
- Analysis of methyl mercaptan, hydrogen sulfide, dimethyl sulfide, and dimethyl disulfide using Shinwasorb
- Column
- β,β’-Oxydipropionitrile 12.5% Shinwasorb-S 60/80 ST
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 70℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 180℃
- Detector temp.
- 180℃
- Detector
- FPD (S)
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Trimethylamine , Dimethylamine , Methylamine
- Applications
- Analysis of methylamines using Shinwasorb
- Column
- Diglycerol+TEP+KOH 7.5+7.5+1% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 70℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 220℃
- Detector temp.
- 220℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- PCBs
- Applications
- Analysis of PCBs using Shinwasorb
- Column
- Silicone OV-17 2% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 210℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- ECD
- Injection volume
- 4.0 μL
View detail
GC
- Samples
- PCBs
- Applications
- Analysis of PCBs using Shinwasorb
- Column
- Silicone OV-1 2% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 195℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- ECD
- Injection volume
- 4.0 μL
View detail
GC
- Samples
- Ethylene oxide , Propylene oxide
- Applications
- Measurement of ethylene oxide using Shinwasorb
- Column
- Flexol 8N8 12.5% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 150℃
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 150℃
- Detector temp.
- 150℃
- Detector
- FID
- Injection volume
- 100 μL
View detail
GC
- Samples
- Dichlorvos (DDVP) , Methyldemeton , Methyl parathion , Parathion , EPN
- Applications
- Measurement of organophosphorus compounds using Shinwasorb
- Column
- Silicone OV-17 1% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 180-250℃ (8℃/min)
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- FPD
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- 2,6-Xylenol , o-Cresol , Phenol , 2,4-Xylenol , p-Cresol , m-Cresol , 3,5-Xylenol , 3,4-Xylenol
- Applications
- Measurements of cresol and xylenol isomers using Shinwasorb
- Column
- FAP-S Shinwasorb-U 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 160℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 250℃
- Detector temp.
- 250℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail