"Shinwsasorb" Filtered 8 Item.

Graph

GC

Samples
Chloroform , Fenitrothion , Fluoranthene
Applications
Analysis of fenitrothion using Shinwasorb
Column
Polyphenyl Ether (5 rings) 1.5% Shinwasorb-S 100/120
Column Size
1.1 m x 3.2 mm I.D. Glass
Column temp.
195℃
Carrier gas
55 mL/min N₂
Injection port temp.
230℃
Detector temp.
230℃
Detector
FID
Injection volume
2.0 μL

View detail


Graph

GC

Samples
Carbonyl sulfide , Hydrogen sulfide , Carbon disulfide , Methyl mercaptan , Ethyl mercaptan , Dimethyl sulfide , Dimethyl disulfide
Applications
Analysis of methyl mercaptan, hydrogen sulfide, dimethyl sulfide, and dimethyl disulfide using Shinwasorb
Column
β,β’-Oxydipropionitrile 12.5% Shinwasorb-S 60/80 ST
Column Size
3.1 m x 3.2 mm I.D. Glass
Column temp.
70℃
Carrier gas
50 mL/min N₂
Injection port temp.
180℃
Detector temp.
180℃
Detector
FPD (S)
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Trimethylamine , Dimethylamine , Methylamine
Applications
Analysis of methylamines using Shinwasorb
Column
Diglycerol+TEP+KOH 7.5+7.5+1% Shinwasorb-S 60/80
Column Size
3.1 m x 3.2 mm I.D. Glass
Column temp.
70℃
Carrier gas
50 mL/min N₂
Injection port temp.
220℃
Detector temp.
220℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
PCBs
Applications
Analysis of PCBs using Shinwasorb
Column
Silicone OV-17 2% Shinwasorb-U 60/80  
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
210℃
Carrier gas
50 mL/min N₂
Injection port temp.
260℃
Detector temp.
260℃
Detector
ECD
Injection volume
4.0 μL

View detail


Graph

GC

Samples
PCBs
Applications
Analysis of PCBs using Shinwasorb
Column
Silicone OV-1 2% Shinwasorb-U 60/80  
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
195℃
Carrier gas
50 mL/min N₂
Injection port temp.
260℃
Detector temp.
260℃
Detector
ECD
Injection volume
4.0 μL

View detail


Graph

GC

Samples
Ethylene oxide , Propylene oxide
Applications
Measurement of ethylene oxide using Shinwasorb
Column
Flexol 8N8 12.5% Shinwasorb-U 60/80
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
150℃
Carrier gas
40 mL/min N₂
Injection port temp.
150℃
Detector temp.
150℃
Detector
FID
Injection volume
100 μL

View detail


Graph

GC

Samples
Dichlorvos (DDVP) , Methyldemeton , Methyl parathion , Parathion , EPN
Applications
Measurement of organophosphorus compounds using Shinwasorb
Column
Silicone OV-17 1% Shinwasorb-S 60/80
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
180-250℃ (8℃/min)
Carrier gas
50 mL/min N₂
Injection port temp.
260℃
Detector temp.
260℃
Detector
FPD
Injection volume
1.0 μL

View detail


Graph

GC

Samples
2,6-Xylenol , o-Cresol , Phenol , 2,4-Xylenol , p-Cresol , m-Cresol , 3,5-Xylenol , 3,4-Xylenol
Applications
Measurements of cresol and xylenol isomers using Shinwasorb
Column
FAP-S Shinwasorb-U 60/80
Column Size
3.1 m x 3.2 mm I.D. Glass
Column temp.
160℃
Carrier gas
50 mL/min N₂
Injection port temp.
250℃
Detector temp.
250℃
Detector
FID
Injection volume
1.0 μL

View detail