Search result
"n-Octane" Filtered 5 Item.
GC
- Samples
- Benzene , n-Octane , Toluene , n-Nonane , Ethylbenzene , p-Xylene , m-Xylene , o-Xylene , Isopropylbenzene , Styrene , n-Decane , p-Ethyltoluene , o-Ethyltoluene , 1,2,4-Trimethylbenzene
- Applications
- Styrene monomer and Lower Hydrocarbons
- Column
- Shinchrom F51+Bentone 34(6%+2%) Chromosorb W 80-100 (AW‐DMCS)
- Column Size
- 2.1m×3.2mm
- Column temp.
- 80°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- n-Pentane , n-Hexane , n-Heptane , n-Octane , Acrolein , Carbon Tetrachloride , Benzene , Acrylonitrile , Acetonitrile , Perchloroethylene , Toluene , Ethylbenzene , m-Xylene , o-Xylene , n-Dodecane , Styrene monomer , n-Tridecane , p-Xylene
- Applications
- Organic solvent in work environment (1)
- Column
- Thermon-1000 25% Shimalite 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 130°C
- Carrier gas
- N2,40ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- n-Hexane, Benzene , n-Octane , Toluene , n-Nonane , Ethylbenzene , p-Xylene , m-Xylene , o-Xylene , Isopropylbenzene , Styrene , n-Propylbenzene , p-Ethyltoluene , m-Ethyltoluene , o-Ethyltoluene , 1,3,5-Trimethylbenzene , 1,2,4-Trimethylbenzene , 1,2,3-Trimethylbenzene , 4-n-Propyltoluene , 3-n-Propyltoluene , 2-n-Propyltoluene , 1,2,3,5-Tetramethylbenzene , 1,2,4,5-Tetramethylbenzene , 1,2,3,4-Tetramethylbenzene
- Applications
- Alkyl benzene isomer
- Column
- ULBON Xylene Master
- Column Size
- 50m×0.32mm
- Column temp.
- 70°C→120°C(2°C/min)
- Carrier gas
- He,1.4ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Methyl iodide , iso-Propyl iodide , n-Octane , o-Xylene
- Applications
- Analysis of hypromellose using Shinwasorb
- Column
- Silicone DC-200 10% Shinwasorb-S 100/120
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 90℃
- Carrier gas
- 38 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Carbon sulfide , Hydrogen sulfide , Carbon disulfide , Methyl mercaptan , Ethyl mercaptane , Dimethyl sulfide
- Applications
- Measurements of offensive odor substances using Shinwasorb -3-
- Column
- 1,2,3-TCEP 25% Shinwasorb-S 80/100 ST
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 70℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 180℃
- Detector temp.
- 180℃
- Detector
- FPD
- Injection volume
- 1.0 μL
View detail