Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Ethylene oxide" Filtered 11 Item.

Graph

GC

Samples
Ethyleneoxide , Propyleneoxide , Ethanol
Applications
Oxirane and propylene oxide in Ethanol (2)
Column
Flexol 8N8 25% Chromosorb W 60-80 (AW-DMCS)
Column Size
2.1m×3.2mm
Column temp.
50°C
Carrier gas
N2,50ml/min
Injection port temp.
200°C
Detector temp.
200°C(FID)

View detail


Graph

GC

Samples
Air , Carbon Monoxide , Methane , Ethane , Carbon Dioxide , Ethylene
Applications
Gas (O2, N2, CO, Methan, Ethan, CO2, Ethylene)
Column
Silica Gel 60-80
Column Size
1.6m×3.2mm
Column temp.
50°C
Carrier gas
He,60ml/min
Injection port temp.
50°C
Detector temp.
50°C(TCD)

View detail


Graph

GC

Samples
Methane , Carbon Dioxide , Ethylene , Ethane , Water
Applications
Methane CO2 Ethylene Ethane
Column
Sunpak-A
Column Size
2.1m×3.2mm
Column temp.
50°C
Carrier gas
He,50ml/min
Injection port temp.
150°C
Detector temp.
150°C(TCD)

View detail


Graph

GC

Samples
Ethyleneoxide , Propyleneoxide , Ethanol
Applications
Oxirane and propylene oxide in Ethanol (1)
Column
TSG-1 15% SHINCARBON A 60-80
Column Size
3.1m×3.2mm
Column temp.
60°C
Carrier gas
N2,50ml/min
Injection port temp.
220°C
Detector temp.
220°C(FID)

View detail


Graph

GC

Samples
Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , Ethane
Applications
Inorganic gas and Lower hydrocarbons (3) Analysis by the 2m column
Column
Shincarbon-ST
Column Size
2m × 3mmI.D.
Column temp.
40°C (5min. hold) → 200°C (10°C/min.)
Carrier gas
He
Detector temp.
200°C
Injection volume
0.5mL

View detail


Graph

GC

Samples
Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , Ethane
Applications
Inorganic gas and Lower hydrocarbons (4) Analysis by the 4m column
Column
Shincarbon-ST
Column Size
4m (2m×2) × 3mmI.D.
Column temp.
40°C (7min. hold) → 200°C (10°C/min.)
Carrier gas
He
Detector temp.
200°C
Injection volume
0.5mL

View detail


Graph

GC

Samples
Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , Ethane
Applications
Inorganic gas and Lower hydrocarbons (5) Analysis by the 6m column
Column
Shincarbon-ST
Column Size
6m (2m×3)) × 3mmI.D.
Column temp.
40°C (12min. hold) → 200°C (10°C/min.)
Carrier gas
He
Detector temp.
200°C
Injection volume
0.5mL

View detail


Graph

GC

Samples
Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , Ethane
Applications
Inorganic gas and Lower hydrocarbons (6) Analysis by the 8m column
Column
Shincarbon-ST
Column Size
8m (2m×4) × 3mmI.D.
Column temp.
40°C (20min. hold) → 200°C (10°C/min.)
Carrier gas
He
Detector temp.
200°C
Injection volume
0.5mL

View detail


Graph

GC

Samples
Oxigen , Nitrogen , Carbon Monoxide , Methane , Carbon Dioxide , Ethylene , Ethane
Applications
Inorganic gas and Lower hydrocarbons (7) Analysis by the 8m column
Column
Micropacked-ST
Column Size
2m × 1mmI.D.
Column temp.
35°C (2min. hold) → 200°C (25°C/min.)
Carrier gas
He,200kPa
Detector temp.
200°C
Injection volume
0.05mL

View detail


Graph

GC

Samples
Ethylene oxide , Propylene oxide
Applications
Measurement of ethylene oxide using Shinwasorb
Column
Flexol 8N8 12.5% Shinwasorb-U 60/80
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
150℃
Carrier gas
40 mL/min N₂
Injection port temp.
150℃
Detector temp.
150℃
Detector
FID
Injection volume
100 μL

View detail


Graph

LC

Samples
Formaldehyde , Methanol , Acetone
Applications
Formaldehyde , Methanol , Acetone
Column
ULTRON PS-80H
Column Size
300 mm L × 8.0 mm I.D.
Mobile phase
HClO4 aq
Frow rate
1.0 mL/min
Column temp.
60°C
Injection volume
10 µL
Diluent
mobile phase

View detail