Search result
"Thermon-3000" Filtered 22 Item.
GC
- Samples
- Propyleneglycol , Ethyleneglycol , Decyl Alcohol , 1,4-Butanediol , Diethyleneglycol , Lauryl Alcohol , Myristyl Alcohol , Triethyleneglycol , Cetyl Alcohol , Stearyl Alcohol
- Applications
- Glycol and higher alcohol
- Column
- Thermon-3000 1% Shimalite TPA 60-80
- Column Size
- 1.1m×3.2mm
- Column temp.
- 90°C→180°C(5°C/min)
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- Catechol , Hydroquinone , Resorcinol
- Applications
- Dihydric phenol in water
- Column
- Thermon-3000 1% Shimalite TPA 60-80
- Column Size
- 0.5m×3.2mm
- Column temp.
- 160°C
- Carrier gas
- N2,60ml/min
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- Pynacol , Butanediol(1,4) , Pentanediol(1,5) , Hexanediol(1,6) , Heptanediol(1,7) , Octanediol(1,8) , Nonanediol(1,9) , Decanediol(1,10)
- Applications
- Diols (standard mixed sample)
- Column
- Thermon-3000 10% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 228°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 270°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- dl-Camphor , l-Menthol , Methyl Salicylate , Thymol
- Applications
- The component of the liniment
- Column
- Thermon-3000 10% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 175°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 250°C
- Detector temp.
- 250°C(FID)
View detail
GC
- Samples
- Capsaicine
- Applications
- Capsaicine (Free)
- Column
- Thermon-3000 2% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 2.1m×3.2mm
- Column temp.
- 260°C
- Carrier gas
- N2,40ml/min
- Injection port temp.
- 290°C
- Detector temp.
- 280°C(FID)
View detail
GC
- Samples
- TBZ(Thiabendazole)
- Applications
- Thiabendazole (TBZ,200ppm)
- Column
- Thermon-3000 2% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 1.1m×3.2mm
- Column temp.
- 220°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 270°C
- Detector temp.
- 270°C(FID)
View detail
GC
- Samples
- Diethyl Phthalate , Di-iso-Butyl Phthalate , Di-n-Butyl Phthalate , Di-n-Amyl Phthalate , Diheptyl Phthalate , Dioctyl Phthalate
- Applications
- Phthalic acid ester (2) (200ppm)
- Column
- Thermon-3000 2% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 2.1m×3.2mm
- Column temp.
- 215°C
- Carrier gas
- N2,65ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- Isobutyric Acid , Isovaleric Acid , Isocaproic Acid , Caproic Acid , Enanthic Acid , Lactic Acid
- Applications
- Free lower fatty acids in water and Lactic acid (1)
- Column
- Thermon-3000 3% Shimalite TPA 60-80
- Column Size
- 1.6m×3.2mm
- Column temp.
- 170°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- β-Phenylethyl Acetamide , Lauryl Acetamide
- Applications
- Acetamide
- Column
- Thermon-3000 5% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 2.1m×3.2mm
- Column temp.
- 200°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- α-Pinene , β-Pinene , Limonene , Octyl Aldehyde , Nonyl Aldehyde , Citronellal , Decyl Aldehyde , Linalool , Linalyl Acetate , Isobornyl Acetate(Citronellol) , Menthol , Benzyl Acetate , Perillaldehyde , Geraniol , α-Ionone , Rose-P , C12-Alcohol , Anisaldehyde , Methyl Cinnamate , Ethyl Cinnamate , Eugenol , Heliotropin , DEP , Vanillin , Benzyl Benzoate , Benzyl Salicylate
- Applications
- The mixed sample of perfume component
- Column
- Thermon-3000 5% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 80°C→250°C(6°C/min)
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 290°C
- Detector temp.
- 280°C(FID)
View detail
GC
- Samples
- Diphenhydramine
- Applications
- Diphenhydramine
- Column
- Thermon-3000 5% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 1.1m×3.2mm
- Column temp.
- 200°C
- Carrier gas
- N2,80ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- Nicotine
- Applications
- Nicotine extracted from the tobacco
- Column
- Thermon-3000 5% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 115°C→205°C(8°C/min)
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- Pyruvic Acid
- Applications
- Pyruvic Acid (Free)
- Column
- Thermon-3000 5% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 2.1m×3.2mm
- Column temp.
- 105°C
- Carrier gas
- N2,30ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Monomethylamine , Dimethylamine , Trimethylamine
- Applications
- Tri-, di-, monomethylamine in Nitrogen
- Column
- Thermon-3000+KOH(5%+1%) Sunpak-A
- Column Size
- 2.1m×3.2mm
- Column temp.
- 150°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Methylamine , Dimethylamine , Trimethylamine
- Applications
- Tri-, di-, monomethylamine in water
- Column
- Thermon-3000+KOH(5%+1%) Sunpak-A
- Column Size
- 2.1m×3.2mm
- Column temp.
- 140°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 250°C
- Detector temp.
- 230°C(FID)
View detail
GC
- Samples
- Monomethylamine , Dimethylamine , Trimethylamine
- Applications
- Tri-, di-, monomethylamine in water
- Column
- Thermon-3000+KOH(5%+1%) Sunpak-A
- Column Size
- 2.1m×3.2mm
- Column temp.
- 140°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- Capric Acid Methyl Ester , Lauric Acid Methyl Ester , Myristic Acid Methyl Ester , Palmitic Acid Methyl Ester , Palmitoleic Acid Methyl Ester , Stearic Acid Methyl Ester , Oleoic Acid Methyl Ester , Linoleic Acid Methyl Ester , Linolenic Acid Methyl Ester , Arachidic Acid Methyl Ester , cis-11-Eicosenoic Acid Methyl Ester , Behenic Acid Methyl Ester , Erucic Acid Methyl Ester , 4,7,10,13,16,19-Docosahexaenoic Acid Methyl Ester , Lignoceric Acid Methyl Ester , Nervonic Acid Methyl Ester
- Applications
- Standard data Fatty acid methyl ester standard (1)
- Column
- ULBON HR-Thermon-3000B
- Column Size
- 50m×0.25mm
- Column temp.
- 180°C→220°C(1°C/min)
- Carrier gas
- He,1.7ml/min
- Detector temp.
- 250°C(FID)
View detail
GC
- Samples
- Fragrance
- Applications
- Measurements of fragrance using Shinwasorb
- Column
- Thermon-3000 5% Shinwasorb-S 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 80~260℃(6℃/min)
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 280℃
- Detector temp.
- 280℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- 200 ppm in hexane
- Applications
- Measurements of eucalyptus oil using Shinwasorb
- Column
- Thermon-3000 5% Shinwasorb-S 80/100
- Column Size
- 5.1 m x 3.2 mm I.D. Glass
- Column temp.
- 120℃ & 130℃
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Ammonia and Mono, Di, Tri-Methylamine in Water ,
- Applications
- Ammonia and Mono, Di, Tri-Methylamine in Water
- Column
- Thermon-3000 + KOH 2+2% Sunpak-N 60/100 mesh
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 120℃
- Carrier gas
- 50 mL/min He
- Injection port temp.
- 250°C
- Detector temp.
- 250°C
- Detector
- TCD
- Injection volume
- 1.0 μL
View detail