Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Chloroform" Filtered 20 Item.

Graph

GC

Samples
Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
Applications
Organic solvent in work environment (2)
Column
SBS-200 20% Shimalite W 100-120 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
100°C
Carrier gas
N2,50ml/min
Injection port temp.
240°C
Detector temp.
240°C(FID)

View detail


Graph

GC

Samples
Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
Applications
Organic solvents of the atmosphere (ppm level)
Column
SBS-200 20% Shimalite W 100-120 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
100°C
Carrier gas
N2,50ml/min
Injection port temp.
240°C
Detector temp.
240°C(FID)

View detail


Graph

GC

Samples
Dichloromethane , trans-1,2-Dichloroethylene , Chloroform , 1,2-Dichloroethane , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Toluene , Tetrachloroethylene , Chlorobenzene , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
Applications
Organic solvents in work environment (3)
Column
SBS-300 20% Shimalite W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
100°C
Carrier gas
N2,30ml/min
Injection port temp.
240°C
Detector temp.
240°C(FID)

View detail


Graph

GC

Samples
Dichloromethane , trans-1,2-Dichloroethylene , Chloroform , 1,2-Dichloroethane , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Toluene , Tetrachloroethylene , Chlorobenzene , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
Applications
Chlorinated solvents of the atmosphere (ppm level)
Column
SBS-300 20% Shimalite W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
100°C
Carrier gas
N2,30ml/min
Injection port temp.
240°C
Detector temp.
240°C(FID)

View detail


Graph

GC

Samples
Chloroform , 1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Chlorodibromomethane , Tetrachloroethylene , Bromoform
Applications
Trihalomethane standard mixed sample (2)
Column
Silicone DC 200 20% Chromosorb W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
80°C
Carrier gas
N2,60ml/min
Injection port temp.
220°C
Detector temp.
220°C(ECD)

View detail


Graph

GC

Samples
Chloroform , 1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Tetrachloroethylene , Chlorodibromomethane , Bromoform
Applications
Trihalomethane standard mixed sample (1)
Column
Silicone DC 550 20% Chromosorb W 80-100 (AW-DMCS)
Column Size
3.1m×3.2mm
Column temp.
90°C
Carrier gas
N2,60ml/min
Injection port temp.
220°C
Detector temp.
220°C(ECD)

View detail


Graph

GC

Samples
Solvents
Applications
Solvents (5)
Column
ULBON HR-1
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→120°C(2°C/min)
Carrier gas
He,0.93ml/min
Detector temp.
150°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Methanol , Ethyl Ether , Isopropanol , trans-1,2-Dichloroethylene , Ethyl Acetate , Chloroform , Isobutanol , Trichloroethylene , n-Butanol , 1,4-Dioxane , Toluene , Tetrachloroethylene , n-Butyl Acetate , Ethylbenzene , p-Xylene , Isoamyl Acetate , o-Xylene , n-Amyl Acetate , Cyclohexanol , Cyclohexanone , 2-Methylcyclohexanol , 2-Methylcyclohexanone , p-Dichlorobenzene , o-Dichlorobenzene , o-Cresol , m-Cresol
Applications
The work environment (2)
Column
ULBON HR-1701
Column Size
30m×0.53mm(5μm)
Column temp.
60°C→180°C(4°C/min)
Carrier gas
He,10ml/min
Detector temp.
200°C(FID)
Injection volume
1ml

View detail


Graph

GC

Samples
Methanol , Ethanol , Acetone , IPA , n-Propanol , Ethyl Acetate , MEK , Chloroform , Benzene , n-Butanol , Toluene , MIBK , Isobutyl Acetate , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cellosolve Acetate
Applications
Solvents (2)
Column
ULBON HR-1701
Column Size
25m×0.32mm(0.5μm)
Column temp.
40°C→90°C(2°C/min)
Carrier gas
He,0.83ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Solvents (4)
Applications
Solvents (4)
Column
ULBON HR-1701
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→180°C(4°C/min)
Carrier gas
He,1.4ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
n-Hexane , Ethyl Ether , Acetone , Methyl Acetate , trans-1,2-Dichloroethylene , Methanol , Isopropyl Acetate , Isopropanol , Dichloromethane , n-Propyl Acetate , cis-1,2-Dichloroethylene , Methyl Isobutyl Ketone , Chloroform , Toluene , 1,4-Dioxane , Isobutanol , Isoamyl Acetate , Ethylbenzene , p-Xylene , m-Xylene , Methyl Cellosolve , o-Xylene , Ethyl Cellosolve , Styrene , Cellosolve Acetate , N,N-Dimethylformamide , 4-Methylcyclohexanone , Butyl Cellosolve , cis-4-Methylcyclohexanol , m-Dichlorobenzene , p-Dichlorobenzene , trans-4-Methylcyclohexanol , o-Dichlorobenzene , o-Cresol , p-Cresol , m-Cresol
Applications
Solvents (6)
Column
ULBON HR-20M
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→240°C(3°C/min)
Carrier gas
He,1.3ml/min
Detector temp.
250°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Methanol , Ethanol , Acetone , n-Propanol , n-Hexane , Ethyl Acetate , Chloroform , Benzene , MIBK , Toluene , Isobutyl Acetate , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cellosolve Acetate
Applications
Solvents (1)
Column
ULBON HR-52
Column Size
25m×0.32mm(0.5μm)
Column temp.
40°C→90°C(2°C/min)
Carrier gas
He,0.83ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Chloroform , Fenitrothion , Fluoranthene
Applications
Analysis of fenitrothion using Shinwasorb
Column
Polyphenyl Ether (5 rings) 1.5% Shinwasorb-S 100/120
Column Size
1.1 m x 3.2 mm I.D. Glass
Column temp.
195℃
Carrier gas
55 mL/min N₂
Injection port temp.
230℃
Detector temp.
230℃
Detector
FID
Injection volume
2.0 μL

View detail


Graph

GC

Samples
Dichloromethane , trans-1,2-Dichloroethylene , Chloroform , 1,2-Dichloroethane , 1,1,1-Trichloroethane , Carbon tetrachloride , Trichloroethylene , Toluene , Tetrachloroethylene , Chlorobenzene , 1,1,2,2,-Tetrachloroethane , o-Dichlorobenzene
Applications
Measurement of chlorinated solvents in air using Shinwasorb
Column
SBS-300 10% Shinwasorb-S 60/80
Column Size
3.1 m x 3.2 mm I.D. Glass
Column temp.
100℃
Carrier gas
30 mL/min N₂
Injection port temp.
240℃
Detector temp.
240℃
Detector
FID
Injection volume
1.0 mL

View detail


Graph

GC

Samples
1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Chlorodibromomethane , Tetrachloroethylene , Bromoform
Applications
Measurements of trihalomethanes using Shinwasorb -1-
Column
Silicone DC-200 10% Shinwasorb-S 60/80
Column Size
3.1 m x 3.2 mm I.D. Glass
Column temp.
100℃
Carrier gas
50 mL/min N₂
Injection port temp.
240℃
Detector temp.
240℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Chlorodibromomethane , Tetrachloroethylene , Bromoform
Applications
Measurements of trihalomethanes using Shinwasorb -2-
Column
Silicone DC-550 10% Shinwasorb-S 60/80
Column Size
3.1 m x 3.2 mm I.D. Glass
Column temp.
90℃
Carrier gas
50 mL/min N₂
Injection port temp.
220℃
Detector temp.
220℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Chloroform , Ethanol , Naphthalene , Amantadine
Applications
Measurements of amantadine hydrochloride using Shinwasorb
Column
Apiezone L+KOH 2+1% Shinwasorb-S 80/100
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
125℃(5 min hold)~150℃(5℃/min)~150℃ (10 min hold)
Carrier gas
50 mL/min N₂
Injection port temp.
200℃
Detector temp.
200℃
Detector
FID
Injection volume
2.0 μL

View detail


Graph

GC

Samples
Chloroform , Trichloroethylene , N,N-dimethylformamide ,
Applications
Analysis of tranilast using Sunpak-H ~Purity test (3) Chloroform~
Column
Sunpak-H 80/100
Column Size
1.1 m x 3.2 mm I.D. Glass
Column temp.
160℃
Carrier gas
45 mL/min N2
Injection port temp.
200℃
Detector temp.
200℃  
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Chloroform , Fenitrothion , Fluoranthene
Applications
Analysis of fenitrothion using Shinwasorb
Column
Polyphenyl Ether (5 rings) 1.5% Shinwasorb-S 100/120
Column Size
1.1 m x 3.2 mm I.D. Glass
Column temp.
195℃
Carrier gas
55 mL/min N₂ (Adjust so that the retention time of fenitrothion is about 16 minutes.)
Injection port temp.
230°C
Detector temp.
230°C
Detector
FID
Injection volume
2.0 μL

View detail


Graph

GC

Samples
HCl , SO2 , Cl2 , CHCl3 , SO2Ci2 , CCl4 ,
Applications
Analysis of sulfuryl chloride
Column
TAKU-1 20% Shimalite-F 40/80
Column Size
5.1 m × 3.2 mm glass
Column temp.
70°C
Carrier gas
He, 40 ml/min
Injection port temp.
150°C
Detector temp.
150°C
Detector
TCD
Injection volume
1.5 μL

View detail