Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Isoamyl Acetate" Filtered 6 Item.

Graph

GC

Samples
n-Hexane , Methyl Alcohol , Acetone , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Trichloroethylene , Isobutyl Alcohol , Isobutyl Acetate , Toluene , n-Butyl Acetate , Isoamyl Alcohol , Ethylbenzene , m-Xylene , o-Xylene , n-Propylbenzene , Cyclohexanone
Applications
Organic solvent in the air (ppm level)
Column
SBS-100 10% Shimalite TPA 60-80
Column Size
3.1m×3.2mm
Column temp.
110°C
Carrier gas
N2,30ml/min
Injection port temp.
200°C
Detector temp.
200°C(FID)

View detail


Graph

GC

Samples
Methanol , Acetaldehyde , Ethanol , Isopropanol , n-Propanol , Ethyl Acetate , Isobutanol , n-Butanol , Isoamyl Alcohol
Applications
Lower alcohol in water
Column
Thermon-1000 5% Sunpak-A
Column Size
2.1m×3.2mm
Column temp.
180°C
Carrier gas
N2,50ml/min
Injection port temp.
240°C
Detector temp.
240°C(FID)

View detail


Graph

GC

Samples
Solvents
Applications
Solvents (5)
Column
ULBON HR-1
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→120°C(2°C/min)
Carrier gas
He,0.93ml/min
Detector temp.
150°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Methanol , Ethyl Ether , Isopropanol , trans-1,2-Dichloroethylene , Ethyl Acetate , Chloroform , Isobutanol , Trichloroethylene , n-Butanol , 1,4-Dioxane , Toluene , Tetrachloroethylene , n-Butyl Acetate , Ethylbenzene , p-Xylene , Isoamyl Acetate , o-Xylene , n-Amyl Acetate , Cyclohexanol , Cyclohexanone , 2-Methylcyclohexanol , 2-Methylcyclohexanone , p-Dichlorobenzene , o-Dichlorobenzene , o-Cresol , m-Cresol
Applications
The work environment (2)
Column
ULBON HR-1701
Column Size
30m×0.53mm(5μm)
Column temp.
60°C→180°C(4°C/min)
Carrier gas
He,10ml/min
Detector temp.
200°C(FID)
Injection volume
1ml

View detail


Graph

GC

Samples
Solvents (4)
Applications
Solvents (4)
Column
ULBON HR-1701
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→180°C(4°C/min)
Carrier gas
He,1.4ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
n-Hexane , Ethyl Ether , Acetone , Methyl Acetate , trans-1,2-Dichloroethylene , Methanol , Isopropyl Acetate , Isopropanol , Dichloromethane , n-Propyl Acetate , cis-1,2-Dichloroethylene , Methyl Isobutyl Ketone , Chloroform , Toluene , 1,4-Dioxane , Isobutanol , Isoamyl Acetate , Ethylbenzene , p-Xylene , m-Xylene , Methyl Cellosolve , o-Xylene , Ethyl Cellosolve , Styrene , Cellosolve Acetate , N,N-Dimethylformamide , 4-Methylcyclohexanone , Butyl Cellosolve , cis-4-Methylcyclohexanol , m-Dichlorobenzene , p-Dichlorobenzene , trans-4-Methylcyclohexanol , o-Dichlorobenzene , o-Cresol , p-Cresol , m-Cresol
Applications
Solvents (6)
Column
ULBON HR-20M
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→240°C(3°C/min)
Carrier gas
He,1.3ml/min
Detector temp.
250°C(FID)
Injection volume
1μl

View detail