Search result
"Methyl Alcohol" Filtered 18 Item.
GC
- Samples
- Methyl Alcohol , Ethyl Alcohol , Isopropyl Alcohol , tert-Butyl Alcohol , n-Propyl Alcohol , sec-Butyl Alcohol , Isobutyl Alcohol , n-Butyl Alcohol , Isoamyl Alcohol , n-Amyl Alcohol
- Applications
- Lower alcohol (2) (each 500ppm)
- Column
- FAL-M 10% Shimalite TPA 60-80
- Column Size
- 2.1m×3.2mm
- Column temp.
- 90°C
- Carrier gas
- N2,40ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Methyl Alcohol , Ethyl Alcohol , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Methyl Isobutyl Ketone , Toluene , Butyl Acetate , Cellosolve , Ethylbenzene , m-Xylene , p-Xylene , o-Xylene , Cyclohexanone
- Applications
- Organic solvents (2)
- Column
- SBS-1 10% Shimalite TPA 60-80
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,40ml/min
- Injection port temp.
- 230°C
- Detector temp.
- 230°C(FID)
View detail
GC
- Samples
- n-Hexane , Methyl Alcohol , Acetone , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Trichloroethylene , Isobutyl Alcohol , Isobutyl Acetate , Toluene , n-Butyl Acetate , Isoamyl Alcohol , Ethylbenzene , m-Xylene , o-Xylene , n-Propylbenzene , Cyclohexanone
- Applications
- Organic solvent in the air (ppm level)
- Column
- SBS-100 10% Shimalite TPA 60-80
- Column Size
- 3.1m×3.2mm
- Column temp.
- 110°C
- Carrier gas
- N2,30ml/min
- Injection port temp.
- 200°C
- Detector temp.
- 200°C(FID)
View detail
GC
- Samples
- Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Organic solvent in work environment (2)
- Column
- SBS-200 20% Shimalite W 100-120 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Organic solvents of the atmosphere (ppm level)
- Column
- SBS-200 20% Shimalite W 100-120 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Ethanol , Isopropyl Alcohol , Methyl Ethyl Ketone
- Applications
- Lower alcohol in water and Ketones
- Column
- Sunpak-A
- Column Size
- 2.1m×3.2mm
- Column temp.
- 180°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- IPA , Methyl Cellosolve , n-Butanol , 1-Methoxy-2-Propanol , Ethyl Cellosolve , Butyl Cellosolve
- Applications
- Lower alcohol and Cellosolves
- Column
- Thermon-1000 5% Sunpak-A
- Column Size
- 2.1m×3.2mm
- Column temp.
- 170°C→220°C(6°C/min)
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- Methyl Alcohol , Acetaldehyde , Ethyl Alcohol , n-Propyl Alcohol , Isobutyl Alcohol , Isoamyl Alcohol
- Applications
- Aldehyde in the wine and Lower alcohol
- Column
- Thermon-1000 5% Sunpak-A
- Column Size
- 2.1m×3.2mm
- Column temp.
- 140°C→180°C(6°C/min)
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- α-Pinene , β-Pinene , Limonene , Octyl Aldehyde , Nonyl Aldehyde , Citronellal , Decyl Aldehyde , Linalool , Linalyl Acetate , Isobornyl Acetate(Citronellol) , Menthol , Benzyl Acetate , Perillaldehyde , Geraniol , α-Ionone , Rose-P , C12-Alcohol , Anisaldehyde , Methyl Cinnamate , Ethyl Cinnamate , Eugenol , Heliotropin , DEP , Vanillin , Benzyl Benzoate , Benzyl Salicylate
- Applications
- The mixed sample of perfume component
- Column
- Thermon-3000 5% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 80°C→250°C(6°C/min)
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 290°C
- Detector temp.
- 280°C(FID)
View detail
GC
- Samples
- Solvents
- Applications
- Solvents (5)
- Column
- ULBON HR-1
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→120°C(2°C/min)
- Carrier gas
- He,0.93ml/min
- Detector temp.
- 150°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Solvents (4)
- Applications
- Solvents (4)
- Column
- ULBON HR-1701
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→180°C(4°C/min)
- Carrier gas
- He,1.4ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Mixture of 22 organic solvents
- Applications
- Measurement of organic solvents using Shinwasorb -2-
- Column
- PEG1500 12.5% Shinwasorb-U 40/60
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 60~120℃ (4℃/min)
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Fragrance
- Applications
- Measurements of fragrance using Shinwasorb
- Column
- Thermon-3000 5% Shinwasorb-S 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 80~260℃(6℃/min)
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 280℃
- Detector temp.
- 280℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Diethyl ether , n-Hexane , Methanol , Methyl acetate , 2-Propanol , Ethyl acetate , Tetrahydrofuran , 2-Butanol , iso-Butanol , Toluene , n-Butyl acetate , Methyl n-butyl ketone , iso-Amyl alcohol , Ethylbenzene , m-Xylene , p-Xylene , o-Xylene , Styrene monomer ,
- Applications
- Measurement of organic solvents using SBS-120
- Column
- SBS-120 12% Shincarbon-A2 80/100
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 90℃
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 230℃
- Detector temp.
- 230℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
LC
- Samples
- α-Phenylethylalchol
- Applications
- α-Phenylethylalchol
- Column
- ULTRON ES-PhCD
- Column Size
- 150 mm L × 6.0 mm I.D.
- Mobile phase
- 20 mM KH2PO4 (pH 4.6)/CH3CN = 90/10
- Frow rate
- 0.6 mL/min
- Column temp.
- 15°C
View detail
LC
- Samples
- Prostaglandin , 2,4,5-Trihydroxybutyrophenone , Nordihydroguaiaretic acid , Butyl hydroxy anisole , Octyl gallate , 2,6-Di-tert-butyl-4-hydroxymethylphenol , Lauryl gallate , 2,6-Di-t-butyl 4-methylphenol
- Applications
- The phenolic system antioxidant (Added to commercial edible oil)
- Column
- STR ODS-II
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- A: 10 mM Phosphoric acid buffer(pH 2.6), B: CH3CN
- Frow rate
- 1.0 mL/min
- Column temp.
- 40°C
View detail
LC
- Samples
- Formaldehyde , Methanol , Acetone
- Applications
- Formaldehyde , Methanol , Acetone
- Column
- ULTRON PS-80H
- Column Size
- 300 mm L × 8.0 mm I.D.
- Mobile phase
- HClO4 aq
- Frow rate
- 1.0 mL/min
- Column temp.
- 60°C
- Injection volume
- 10 µL
- Diluent
- mobile phase
View detail