Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Naphthalene" Filtered 7 Item.

Graph

GC

Samples
Naphthalene , Biphenyl , Fluorene , Phenanthrene , Anthracene , o-Terphenyl , Fluoranthene , Pyrene , m-Terphenyl , p-Terphenyl , Chrysene , 4,5-Benzpyrene , 1,2-Benzpyrene , Perylene
Applications
Polycyclic aromatic hydrocarbon
Column
ULBON HR-1
Column Size
50m×0.25mm(0.25μm)
Column temp.
200°C→320°C(4°C/min)
Carrier gas
He,068ml/min
Detector temp.
330°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Benzene , Toluene , Ethylbenzene , p-Xylene , m-Xylene , iso-Propylbenzene , o-Xylene , n-Propylbenzene , p-Ethyltoluene , m-Ethyltoluene , o-Ethyltoluene , 1,2,5-Trimethylbenzene , 1,2,4-Trimethylbenzene , 1,2,3-Trimethylbenzene , Naphthalene
Applications
Aromatic hydrocarbons in Premium gasoline
Column
ULBON HR-20M
Column Size
50m×0.25mm(0.5μm)
Column temp.
50°C→180°C(2°C/min)
Carrier gas
He,1.04ml/min
Detector temp.
250°C(FID)
Injection volume
0.2μl

View detail


Graph

GC

Samples
Benzene , Toluene , Ethylbenzene , p-Xylene , m-Xylene , iso-Propylbenzene , o-Xylene , n-Propylbenzene , p-Ethyltoluene , m-Ethyltoluene , o-Ethyltoluene , 1,2,5-Trimethylbenzene , 1,2,4-Trimethylbenzene , 1,2,3-Trimethylbenzene , Naphthalene
Applications
Aromatic hydrocarbons in Regular gasoline
Column
ULBON HR-20M
Column Size
50m×0.25mm(0.5μm)
Column temp.
50°C→180°C(2°C/min)
Carrier gas
He,1.04ml/min
Detector temp.
250°C(FID)
Injection volume
0.2μl

View detail


Graph

GC

Samples
Chloroform , Ethanol , Naphthalene , Amantadine
Applications
Measurements of amantadine hydrochloride using Shinwasorb
Column
Apiezone L+KOH 2+1% Shinwasorb-S 80/100
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
125℃(5 min hold)~150℃(5℃/min)~150℃ (10 min hold)
Carrier gas
50 mL/min N₂
Injection port temp.
200℃
Detector temp.
200℃
Detector
FID
Injection volume
2.0 μL

View detail


Graph

GC

Samples
Cyclohexane , N,N-dimethylaniline , Naphthalene ,
Applications
Analysis of ampicillin hydrate using Shinwasorb
Column
Silicone OV-17 1.5% Shinwasorb-S 60/80
Column Size
2.1 m x 2.6 mm I.D. Glass
Column temp.
105℃
Carrier gas
20 mL/min He(adjust so that the retention time of N,N-dimethylaniline is about 5 minutes.)
Injection port temp.
200°C
Detector temp.
200°C
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Acetone , Dichlorvos , 1-chloronaphthalene
Applications
Analysis of dichlorvos using Shinwasorb
Column
Silicone DC-550 10% Shinwasorb-S 60/80
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
180℃
Carrier gas
40 mL/min N₂ (Adjust so that the retention time of dichlorvos is about 6 minutes.)
Injection port temp.
230°C
Detector temp.
230°C
Detector
FID
Injection volume
2.0 μL

View detail


Graph

LC

Samples
1,1'-Bi-2-naphthol
Applications
1,1'-Bi-2-naphthol
Column
ULTRON ES-PhCD
Column Size
150 mm L × 6.0 mm I.D.
Mobile phase
n-Hexane/Dichloromethane/CH3OH = 75/25/5
Frow rate
1.2 mL/min
Column temp.
25°C

View detail