Search result
"Naphthalene" Filtered 7 Item.
GC
- Samples
- Naphthalene , Biphenyl , Fluorene , Phenanthrene , Anthracene , o-Terphenyl , Fluoranthene , Pyrene , m-Terphenyl , p-Terphenyl , Chrysene , 4,5-Benzpyrene , 1,2-Benzpyrene , Perylene
- Applications
- Polycyclic aromatic hydrocarbon
- Column
- ULBON HR-1
- Column Size
- 50m×0.25mm(0.25μm)
- Column temp.
- 200°C→320°C(4°C/min)
- Carrier gas
- He,068ml/min
- Detector temp.
- 330°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Benzene , Toluene , Ethylbenzene , p-Xylene , m-Xylene , iso-Propylbenzene , o-Xylene , n-Propylbenzene , p-Ethyltoluene , m-Ethyltoluene , o-Ethyltoluene , 1,2,5-Trimethylbenzene , 1,2,4-Trimethylbenzene , 1,2,3-Trimethylbenzene , Naphthalene
- Applications
- Aromatic hydrocarbons in Premium gasoline
- Column
- ULBON HR-20M
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 50°C→180°C(2°C/min)
- Carrier gas
- He,1.04ml/min
- Detector temp.
- 250°C(FID)
- Injection volume
- 0.2μl
View detail
GC
- Samples
- Benzene , Toluene , Ethylbenzene , p-Xylene , m-Xylene , iso-Propylbenzene , o-Xylene , n-Propylbenzene , p-Ethyltoluene , m-Ethyltoluene , o-Ethyltoluene , 1,2,5-Trimethylbenzene , 1,2,4-Trimethylbenzene , 1,2,3-Trimethylbenzene , Naphthalene
- Applications
- Aromatic hydrocarbons in Regular gasoline
- Column
- ULBON HR-20M
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 50°C→180°C(2°C/min)
- Carrier gas
- He,1.04ml/min
- Detector temp.
- 250°C(FID)
- Injection volume
- 0.2μl
View detail
GC
- Samples
- Chloroform , Ethanol , Naphthalene , Amantadine
- Applications
- Measurements of amantadine hydrochloride using Shinwasorb
- Column
- Apiezone L+KOH 2+1% Shinwasorb-S 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 125℃(5 min hold)~150℃(5℃/min)~150℃ (10 min hold)
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Cyclohexane , N,N-dimethylaniline , Naphthalene ,
- Applications
- Analysis of ampicillin hydrate using Shinwasorb
- Column
- Silicone OV-17 1.5% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 2.6 mm I.D. Glass
- Column temp.
- 105℃
- Carrier gas
- 20 mL/min He(adjust so that the retention time of N,N-dimethylaniline is about 5 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Acetone , Dichlorvos , 1-chloronaphthalene
- Applications
- Analysis of dichlorvos using Shinwasorb
- Column
- Silicone DC-550 10% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 180℃
- Carrier gas
- 40 mL/min N₂ (Adjust so that the retention time of dichlorvos is about 6 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
LC
- Samples
- 1,1'-Bi-2-naphthol
- Applications
- 1,1'-Bi-2-naphthol
- Column
- ULTRON ES-PhCD
- Column Size
- 150 mm L × 6.0 mm I.D.
- Mobile phase
- n-Hexane/Dichloromethane/CH3OH = 75/25/5
- Frow rate
- 1.2 mL/min
- Column temp.
- 25°C