Search result
"Pyridine" Filtered 17 Item.
GC
- Samples
- Pyridine , N,N-dimethylformamide
- Applications
- Analysis of niceritrol using Shinwasorb
- Column
- PEG20M 5% Shinwasorb-S 80/100
- Column Size
- 3.1m x3.2 mm I.D. Glass
- Column temp.
- 160°C
- Carrier gas
- N2, 55ml/min
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
LC
- Samples
- Bay K 8644
- Applications
- Calcium rivalry medicine
- Column
- ULTRON ES-OVM
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM KH2PO4 (pH 4.6)/C2H5OH = 100/25
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
View detail
LC
- Samples
- Nicotinic acid , Nicotinamide , Pantothenic acid , Pyridoxine , Riboflavin phosphate , Thiamine , Caffeine , Folic acid , Biotin , Riboflavin
- Applications
- The water-soluble vitamin (1)
- Column
- STR ODS-II
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 100 mM Phosphoric acid buffer(pH 2.1) + 0.8 mM Octane sodium sulphonate/CH3CN = 9/1
- Frow rate
- 1.0 mL/min
- Column temp.
- 40°C
View detail
LC
- Samples
- Pyridoxal , Pyridoxine , Pyridoxamine
- Applications
- The water-soluble vitamin (2)
- Column
- STR ODS-II
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 100 mM Phosphoric acid buffer(pH 2.1) + 50 mM Hexane sodium sulphonate/CH3CN = 9/1
- Frow rate
- 1.0 mL/min
- Column temp.
- 45°C
View detail
LC
- Samples
- Pyridine , Phenol
- Applications
- Pyridine, Phenol test
- Column
- ULTRON VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- CH3CN/H2O = 30/70
- Frow rate
- 1.0 mL/min
- Column temp.
- 30°C
View detail
LC
- Samples
- Nicotinic acid , Nicotinic acid amide , Calcium pantothenate , Pyridoxine hydrochloride , Riboflavin phosphate , Thiamine , Folic acid , Biotin , Riboflavin
- Applications
- The water-soluble vitamin
- Column
- ULTRON VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM H3PO4/5 mM Sodium 1-hexanesulfonate = 91/9
- Frow rate
- 1.0 mL/min
- Column temp.
- 45°C
View detail
LC
- Samples
- Nicotinamide , Pyridoxine , Isoascorbic acid , Riboflavin , Nicotinic acid , Ascorbic acid , Biotin , Pantothenic acid , Folic acid , Cyanocobalamin , Thiamine
- Applications
- Water-soluble vitamins
- Column
- ULTRON AF-HILIC-CD
- Column Size
- 150 mm L × 2.0 mm I.D.
- Mobile phase
- A: 20 mM CH3CO2NH4(pH 6.8)/CH3CN = 10/90, B: 20 mM CH3CO2NH4(pH 6.8)/CH3CN = 70/30
- Frow rate
- 0.25 mL/min
- Column temp.
- 30°C
- Injection volume
- 1.0 µL
View detail
LC
- Samples
- Nitrendipine
- Applications
- Analysis of Nitrendipine
- Column
- ULTRON ES-OVM
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM KH2PO4 (pH 4.6)/CH3CN = 85/15
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
- Injection volume
- 2.0 µL
- Diluent
- methanol
View detail
LC
- Samples
- Nisoldipine
- Applications
- Analysis of Nisoldipine
- Column
- ULTRON ES-OVM
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM KH2PO4 + H3PO4 (pH 3.0)/CH3CN = 88/12
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
- Injection volume
- 2.0 µL
- Diluent
- ethanol
View detail
LC
- Samples
- Clopidogrel Related Compound A , Clopidogrel Related Compound B , Clopidogrel Related Compound C , Clopidogrel bisulfate
- Applications
- Analysis of Clopidogrel Related Compounds
- Column
- ULTRON ES-OVM
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 10 mM KH2PO4/CH3CN = 75/25
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
- Injection volume
- 10.0 µL
View detail
LC
- Samples
- Clopidogrel Related Compound A , Clopidogrel Related Compound B , Clopidogrel Related Compound C , Clopidogrel bisulfate
- Applications
- Analysis of Clopidogrel Related Compounds
- Column
- ULTRON ES-OVM
- Column Size
- 100 mm L × 3.0 mm I.D.
- Mobile phase
- 10 mM KH2PO4/CH3CN = 75/25
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
- Injection volume
- 3.0 µL
View detail
LC
- Samples
- Amlodipine
- Applications
- Analysis of Amlodipine
- Column
- ULTRON ES-OVM
- Column Size
- 100 mm L × 3.0 mm I.D.
- Mobile phase
- 20 mM KH2PO4 (pH 4.6)/CH3CN = 90/10
- Frow rate
- 0.28 mL/min
- Column temp.
- 25°C
- Injection volume
- 0.5 µL
- Diluent
- methanol
View detail
LC
- Samples
- Amlodipine
- Applications
- Analysis of Amlodipine for LCMS
- Column
- ULTRON ES-OVM
- Column Size
- 150 mm L × 2.0 mm I.D.
- Mobile phase
- 20 mM CH3CO2NH4/CH3CN = 80/20
- Frow rate
- 0.2 mL/min
- Column temp.
- 25°C
- Injection volume
- 0.4 µL
- Diluent
- H2O /CH3CN = 50/50 (v/v)
View detail