Search result
"Sucrose" Filtered 13 Item.
GC
- Samples
- Sucrose , Maltose , Lactose , Raffinose
- Applications
- Sugar
- Column
- ULBON HR-1701
- Column Size
- 25m×0.25mm(0.25μm)
- Column temp.
- 180°C→280°C(4°C/min)
- Carrier gas
- He,0.49ml/min
- Detector temp.
- 300°C(FID)
- Injection volume
- 1μl
View detail
LC
- Samples
- Sucrose , Lactose , Glucose , Galactose , Fructose
- Applications
- Yoghurt drink
- Column
- ULTRON PS-80C
- Column Size
- 300 mm L × 8.0 mm I.D.
- Mobile phase
- H2O
- Frow rate
- 0.5 mL/min
- Column temp.
- 80°C
- Pressure
- 2.0 MPa
- Injection volume
- 10 µL
View detail
LC
- Samples
- Sucrose , Lactose , Glucose , Xylose , Galactose , Fructose , Inositol
- Applications
- Sugar and alditol
- Column
- ULTRON PS-80P
- Column Size
- 300 mm L × 8.0 mm I.D.
- Mobile phase
- H2O
- Frow rate
- 1.0 mL/min
- Column temp.
- 80°C
- Pressure
- 2.0 MPa
View detail
LC
- Samples
- Ethyl α-D-glucoside , Fructose , Glucose , Sucrose , Maltose , Lactose
- Applications
- Sugars in food
- Column
- ULTRON AF-HILIC-CD
- Column Size
- 150 mm L × 2.0 mm I.D.
- Mobile phase
- 10 mM CH3CO2NH4(pH 6.8)/CH3CN = 12/88
- Frow rate
- 0.3 mL/min
- Column temp.
- 40°C
- Injection volume
- 1.0 µL (each 1 mg/mL)
View detail
LC
- Samples
- Xylose , Fructose , Glucose , Mannitol , Xylobiose , Sucrose , Lactulose , Lactose , Trehalose , Xylotriose , 1-Kestose(GF2) , Raffinose , Nystose(GF3) ,
- Applications
- Analysis of monosaccharides, disaccharides, and oligosaccharides
- Column
- ULTRON AF-HILIC-CD
- Column Size
- 100 mm L × 2.0 mm I.D.
- Mobile phase
- A: H2O /CH3CN = 10/90, B: H2O /CH3CN = 70/30
- Frow rate
- 0.26 mL/min
- Column temp.
- 40°C
- Injection volume
- 1.0 µL
- Diluent
- H2O /CH3CN = 50/50
View detail
LC
- Samples
- Xylose , Fructose , Glucose , Mannitol , Xylobiose , Sucrose , Lactulose , Lactose , Trehalose , Xylotriose , 1-Kestose(GF2) , Raffinose , Nystose(GF3) ,
- Applications
- Analysis of monosaccharides, disaccharides, and oligosaccharides
- Column
- ULTRON AF-HILIC-CD
- Column Size
- 100 mm L × 2.0 mm I.D.
- Mobile phase
- A: 20mM CH3CO2NH4 (pH6.8) /CH3CN = 10/90, B: 20mM CH3CO2NH4 (pH6.8) /CH3CN = 70/30
- Frow rate
- 0.26 mL/min
- Column temp.
- 40°C
- Injection volume
- 2.5 µL
- Diluent
- H2O /CH3CN = 50/50
View detail
LC
- Samples
- Erythritol , Xylitol , Fructose , Glucose , Sorbitol , Sucrose , Inositol , Maltose , Maltitol , Lactose , Lactitol
- Applications
- Analysis of saccharides and sweeteners
- Column
- ULTRON AF-HILIC-CD
- Column Size
- 150 mm L × 2.0 mm I.D.
- Mobile phase
- A: 100mM CH3CO2NH4 (pH6.8) /CH3CN = 10/90, B: 100mM CH3CO2NH4 (pH6.8) /CH3CN = 70/30
- Frow rate
- 0.32 mL/min
- Column temp.
- 40°C
- Injection volume
- 1.0 µL
- Diluent
- H2O /CH3CN = 50/50
View detail
LC
- Samples
- Erythritol , Psicose , Tagatose , Allose , Glucose , Sucrose
- Applications
- Analysis of rare sugar, Glucose, and Sucrose
- Column
- ULTRON AF-HILIC-CD
- Column Size
- 150 mm L × 2.0 mm I.D.
- Mobile phase
- 100mM CH3CO2NH4 (pH6.8) /CH3CN = 10/90
- Frow rate
- 0.36 mL/min
- Column temp.
- 40°C
- Injection volume
- 1.0 µL
- Diluent
- H2O /CH3CN = 50/50
View detail
LC
- Samples
- Sucralose , Fructose , Glucose , Sucrose , Lactose
- Applications
- Analysis of artificial sweetener and sugars
- Column
- ULTRON AF-HILIC-CD
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 100mM CH3CO2NH4 (pH6.8) /CH3CN = 15/85
- Frow rate
- 1.0 mL/min
- Column temp.
- 40°C
- Injection volume
- 10.0 µL
- Diluent
- H2O /CH3CN = 50/50
View detail
LC
- Samples
- Ethanol , Acetic Acid , 1,4-Sorbitan , Fructose , Glucose , Sorbitol , Sucrose , Maltitol , Maltotriose
- Applications
- Analysis of ethanol, acetic acid, and sugars
- Column
- ULTRON AF-HILIC-CD
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 10 mM HCO2NH4 (pH 4.0)/CH3CN = 17/83
- Frow rate
- 0.5 mL/min
- Column temp.
- 40°C
- Injection volume
- 10 µL
- Diluent
- mobile phase
View detail