Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"Sucrose" Filtered 13 Item.

Graph

GC

Samples
Sucrose , Maltose , Lactose , Raffinose
Applications
Sugar
Column
ULBON HR-1701
Column Size
25m×0.25mm(0.25μm)
Column temp.
180°C→280°C(4°C/min)
Carrier gas
He,0.49ml/min
Detector temp.
300°C(FID)
Injection volume
1μl

View detail


Graph

LC

Samples
Sucrose , Lactose , Glucose , Galactose , Fructose
Applications
Yoghurt drink
Column
ULTRON PS-80C
Column Size
300 mm L × 8.0 mm I.D.
Mobile phase
H2O
Frow rate
0.5 mL/min
Column temp.
80°C
Pressure
2.0 MPa
Injection volume
10 µL

View detail


Graph

LC

Samples
Sucrose , Lactose , Glucose , Xylose , Galactose , Fructose , Inositol
Applications
Sugar and alditol
Column
ULTRON PS-80P
Column Size
300 mm L × 8.0 mm I.D.
Mobile phase
H2O
Frow rate
1.0 mL/min
Column temp.
80°C
Pressure
2.0 MPa

View detail


Graph

LC

Samples
Ethyl α-D-glucoside , Fructose , Glucose , Sucrose , Maltose , Lactose
Applications
Sugars in food
Column
ULTRON AF-HILIC-CD
Column Size
150 mm L × 2.0 mm I.D.
Mobile phase
10 mM CH3CO2NH4(pH 6.8)/CH3CN = 12/88
Frow rate
0.3 mL/min
Column temp.
40°C
Injection volume
1.0 µL (each 1 mg/mL)

View detail


Graph

LC

Samples
Xylose , Fructose , Glucose , Mannitol , Xylobiose , Sucrose , Lactulose , Lactose , Trehalose , Xylotriose , 1-Kestose(GF2) , Raffinose , Nystose(GF3) ,
Applications
Analysis of monosaccharides, disaccharides, and oligosaccharides
Column
ULTRON AF-HILIC-CD
Column Size
100 mm L × 2.0 mm I.D.
Mobile phase
A: H2O /CH3CN = 10/90, B: H2O /CH3CN = 70/30
Frow rate
0.26 mL/min
Column temp.
40°C
Injection volume
1.0 µL
Diluent
H2O /CH3CN = 50/50

View detail


Graph

LC

Samples
Xylose , Fructose , Glucose , Mannitol , Xylobiose , Sucrose , Lactulose , Lactose , Trehalose , Xylotriose , 1-Kestose(GF2) , Raffinose , Nystose(GF3) ,
Applications
Analysis of monosaccharides, disaccharides, and oligosaccharides
Column
ULTRON AF-HILIC-CD
Column Size
100 mm L × 2.0 mm I.D.
Mobile phase
A: 20mM CH3CO2NH4 (pH6.8) /CH3CN = 10/90, B: 20mM CH3CO2NH4 (pH6.8) /CH3CN = 70/30
Frow rate
0.26 mL/min
Column temp.
40°C
Injection volume
2.5 µL
Diluent
H2O /CH3CN = 50/50

View detail


Graph

LC

Samples
Erythritol , Xylitol , Fructose , Glucose , Sorbitol , Sucrose , Inositol , Maltose , Maltitol , Lactose , Lactitol
Applications
Analysis of saccharides and sweeteners
Column
ULTRON AF-HILIC-CD
Column Size
150 mm L × 2.0 mm I.D.
Mobile phase
A: 100mM CH3CO2NH4 (pH6.8) /CH3CN = 10/90, B: 100mM CH3CO2NH4 (pH6.8) /CH3CN = 70/30
Frow rate
0.32 mL/min
Column temp.
40°C
Injection volume
1.0 µL
Diluent
H2O /CH3CN = 50/50

View detail


Graph

LC

Samples
Erythritol , Psicose , Tagatose , Allose , Glucose , Sucrose
Applications
Analysis of rare sugar, Glucose, and Sucrose
Column
ULTRON AF-HILIC-CD
Column Size
150 mm L × 2.0 mm I.D.
Mobile phase
100mM CH3CO2NH4 (pH6.8) /CH3CN = 10/90
Frow rate
0.36 mL/min
Column temp.
40°C
Injection volume
1.0 µL
Diluent
H2O /CH3CN = 50/50

View detail


Graph

LC

Samples
Sucralose , Fructose , Glucose , Sucrose , Lactose
Applications
Analysis of artificial sweetener and sugars
Column
ULTRON AF-HILIC-CD
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
100mM CH3CO2NH4 (pH6.8) /CH3CN = 15/85
Frow rate
1.0 mL/min
Column temp.
40°C
Injection volume
10.0 µL
Diluent
H2O /CH3CN = 50/50

View detail


Graph

LC

Samples
Sucralose , Fructose , Glucose , Sucrose , Lactose
Applications
Analysis of artificial sweetener and sugars
Column
ULTRON PS-80N
Column Size
300 mm L × 8.0 mm I.D.
Mobile phase
H2O
Frow rate
1.0 mL/min
Column temp.
80°C
Injection volume
10.0 µL

View detail


Graph

LC

Samples
Sucralose , Fructose , Glucose , Sucrose , Lactose
Applications
Analysis of artificial sweetener and sugars
Column
ULTRON PS-80C
Column Size
300 mm L × 8.0 mm I.D.
Mobile phase
H2O
Frow rate
1.0 mL/min
Column temp.
80°C
Injection volume
10.0 µL

View detail


Graph

LC

Samples
Sucralose , Fructose , Glucose , Sucrose , Lactose
Applications
Analysis of artificial sweetener and sugars
Column
ULTRON PS-80P
Column Size
300 mm L × 8.0 mm I.D.
Mobile phase
H2O
Frow rate
1.0 mL/min
Column temp.
80°C
Injection volume
10.0 µL

View detail


Graph

LC

Samples
Ethanol , Acetic Acid , 1,4-Sorbitan , Fructose , Glucose , Sorbitol , Sucrose , Maltitol , Maltotriose
Applications
Analysis of ethanol, acetic acid, and sugars
Column
ULTRON AF-HILIC-CD
Column Size
150 mm L × 4.6 mm I.D.
Mobile phase
10 mM HCO2NH4 (pH 4.0)/CH3CN = 17/83
Frow rate
0.5 mL/min
Column temp.
40°C
Injection volume
10 µL
Diluent
mobile phase

View detail