Search result
"Tetrahydrofuran" Filtered 5 Item.
GC
- Samples
- Solvents
- Applications
- Solvents (5)
- Column
- ULBON HR-1
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→120°C(2°C/min)
- Carrier gas
- He,0.93ml/min
- Detector temp.
- 150°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Methyl Isobutyl Ketone , Toluene , Methyl Butyl Ketone , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , 1,1,2,2-Tetrachloroethane , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Cresol , p-Cresol
- Applications
- The work environment (1)
- Column
- ULBON HR-52
- Column Size
- 30m×0.53mm(5μm)
- Column temp.
- 60°C→130°C(3°C/min)
- Carrier gas
- He,8.0ml/min
- Detector temp.
- 150°C(FID)
- Injection volume
- 1ml
View detail
GC
- Samples
- Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , 1,4-Dioxane , Methyl Isobutyl Ketone , Toluene , Methyl n-Butyl Ketone , n-Butyl Acetate , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , o-Xylene , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , 3-Methylcyclohexanol(cis, trans) , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Dichlorobenzene , o-Cresol , p-Cresol
- Applications
- Solvents (3)
- Column
- ULBON HR-52
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→130°C(3°C/min)
- Carrier gas
- He,1.2ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Diethyl ether , n-Hexane , Methanol , Methyl acetate , 2-Propanol , Ethyl acetate , Tetrahydrofuran , 2-Butanol , iso-Butanol , Toluene , n-Butyl acetate , Methyl n-butyl ketone , iso-Amyl alcohol , Ethylbenzene , m-Xylene , p-Xylene , o-Xylene , Styrene monomer ,
- Applications
- Measurement of organic solvents using SBS-120
- Column
- SBS-120 12% Shincarbon-A2 80/100
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 90ā
- Carrier gas
- 40 mL/min Nā
- Injection port temp.
- 230ā
- Detector temp.
- 230ā
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
LC
- Samples
- β-Carotene
- Applications
- β-Carotene
- Column
- ULTRON VX-ODS
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- CH3OH/Tetrahydrofuran = 9/1 + 0.05% BHT
- Frow rate
- 1.0 mL/min
- Column temp.
- 40°C
View detail