Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"n-Propyl Acetate" Filtered 8 Item.

Graph

GC

Samples
n-Hexane , Methyl Alcohol , Acetone , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Trichloroethylene , Isobutyl Alcohol , Isobutyl Acetate , Toluene , n-Butyl Acetate , Isoamyl Alcohol , Ethylbenzene , m-Xylene , o-Xylene , n-Propylbenzene , Cyclohexanone
Applications
Organic solvent in the air (ppm level)
Column
SBS-100 10% Shimalite TPA 60-80
Column Size
3.1m×3.2mm
Column temp.
110°C
Carrier gas
N2,30ml/min
Injection port temp.
200°C
Detector temp.
200°C(FID)

View detail


Graph

GC

Samples
Dimethyl Ether , Methanol , Isopropanol , Methyl Ethyl Ketone , Isopropyl Acetate , 2-Butanol , n-Propyl Acetate , Isobutanol , Dioxane , Methyl Cellosolve , Toluene , Ethyl Cellosolve , N,N-Dimethylformamide , Chlorobenzene , Cellosolve Acetate , Cyclohexanone , Cyclohexanol , 2-Methyl Cyclohexanone , 2-Methyl Cyclohexanol , o-Dichlorobenzene
Applications
Organic solvents (4)
Column
Ucon LB 550X 20% Chromosorb W 80-100 (AW)
Column Size
3.1m×3.2mm
Column temp.
100°C
Carrier gas
N2,50ml/min
Injection port temp.
230°C
Detector temp.
230°C(FID)

View detail


Graph

GC

Samples
Solvents
Applications
Solvents (5)
Column
ULBON HR-1
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→120°C(2°C/min)
Carrier gas
He,0.93ml/min
Detector temp.
150°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Solvents (4)
Applications
Solvents (4)
Column
ULBON HR-1701
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→180°C(4°C/min)
Carrier gas
He,1.4ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
n-Hexane , Ethyl Ether , Acetone , Methyl Acetate , trans-1,2-Dichloroethylene , Methanol , Isopropyl Acetate , Isopropanol , Dichloromethane , n-Propyl Acetate , cis-1,2-Dichloroethylene , Methyl Isobutyl Ketone , Chloroform , Toluene , 1,4-Dioxane , Isobutanol , Isoamyl Acetate , Ethylbenzene , p-Xylene , m-Xylene , Methyl Cellosolve , o-Xylene , Ethyl Cellosolve , Styrene , Cellosolve Acetate , N,N-Dimethylformamide , 4-Methylcyclohexanone , Butyl Cellosolve , cis-4-Methylcyclohexanol , m-Dichlorobenzene , p-Dichlorobenzene , trans-4-Methylcyclohexanol , o-Dichlorobenzene , o-Cresol , p-Cresol , m-Cresol
Applications
Solvents (6)
Column
ULBON HR-20M
Column Size
50m×0.25mm(0.5μm)
Column temp.
60°C→240°C(3°C/min)
Carrier gas
He,1.3ml/min
Detector temp.
250°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Mixture of 22 organic solvents
Applications
Measurement of organic solvents using Shinwasorb -2-
Column
PEG1500 12.5% Shinwasorb-U 40/60
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
60~120℃ (4℃/min)
Carrier gas
40 mL/min N₂
Injection port temp.
200℃
Detector temp.
200℃
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Organic solvents
Applications
Analysis of organic solvents using Sunpak-A -1-
Column
Sunpak-A 50/80
Column Size
2.0 m x 3.0 mm I.D. Glass
Column temp.
150℃ ~ 220℃ (3 min hold) program rate 4℃/min
Carrier gas
50 mL/min N₂
Injection port temp.
250°C
Detector temp.
250°C
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Organic solvents
Applications
Analysis of organic solvents using Sunpak-A -2-
Column
Sunpak-A 50/80
Column Size
2.0 m x 3.0 mm I.D. Glass
Column temp.
150℃ ~ 220℃ (3 min hold) program rate 4℃/min
Carrier gas
50 mL/min N₂
Injection port temp.
250°C
Detector temp.
250°C
Detector
FID
Injection volume
1.0 μL

View detail