Search result
"Acetone" Filtered 36 Item.
GC
- Samples
- Acetic Acid , Propionic Acid , Isobutyric Acid , Butyric Acid , Isovaleric Acid , Valeric Acid , Isocaproic Acid , Caproic Acid
- Applications
- Free lower fatty acids in Acetone(each 200ppm)
- Column
- FON 20% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 2.1m×3.2mm
- Column temp.
- 170°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 250°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- n-Hexane , Methyl Alcohol , Acetone , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Trichloroethylene , Isobutyl Alcohol , Isobutyl Acetate , Toluene , n-Butyl Acetate , Isoamyl Alcohol , Ethylbenzene , m-Xylene , o-Xylene , n-Propylbenzene , Cyclohexanone
- Applications
- Organic solvent in the air (ppm level)
- Column
- SBS-100 10% Shimalite TPA 60-80
- Column Size
- 3.1m×3.2mm
- Column temp.
- 110°C
- Carrier gas
- N2,30ml/min
- Injection port temp.
- 200°C
- Detector temp.
- 200°C(FID)
View detail
GC
- Samples
- Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Organic solvent in work environment (2)
- Column
- SBS-200 20% Shimalite W 100-120 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Organic solvents of the atmosphere (ppm level)
- Column
- SBS-200 20% Shimalite W 100-120 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Benzene , Toluene , Acetone , iso-Propanol , Ethanol , Isobutanol , Methanol
- Applications
- The impurity component in the carbinol
- Column
- Sorbitol 30% Shimalite 60-80 (NAW)
- Column Size
- 6.1m×3.2mm
- Column temp.
- 110°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Solvents
- Applications
- Solvents (5)
- Column
- ULBON HR-1
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→120°C(2°C/min)
- Carrier gas
- He,0.93ml/min
- Detector temp.
- 150°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Methanol , Ethanol , Acetone , IPA , n-Propanol , Ethyl Acetate , MEK , Chloroform , Benzene , n-Butanol , Toluene , MIBK , Isobutyl Acetate , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cellosolve Acetate
- Applications
- Solvents (2)
- Column
- ULBON HR-1701
- Column Size
- 25m×0.32mm(0.5μm)
- Column temp.
- 40°C→90°C(2°C/min)
- Carrier gas
- He,0.83ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- n-Hexane , Ethyl Ether , Acetone , Methyl Acetate , trans-1,2-Dichloroethylene , Methanol , Isopropyl Acetate , Isopropanol , Dichloromethane , n-Propyl Acetate , cis-1,2-Dichloroethylene , Methyl Isobutyl Ketone , Chloroform , Toluene , 1,4-Dioxane , Isobutanol , Isoamyl Acetate , Ethylbenzene , p-Xylene , m-Xylene , Methyl Cellosolve , o-Xylene , Ethyl Cellosolve , Styrene , Cellosolve Acetate , N,N-Dimethylformamide , 4-Methylcyclohexanone , Butyl Cellosolve , cis-4-Methylcyclohexanol , m-Dichlorobenzene , p-Dichlorobenzene , trans-4-Methylcyclohexanol , o-Dichlorobenzene , o-Cresol , p-Cresol , m-Cresol
- Applications
- Solvents (6)
- Column
- ULBON HR-20M
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→240°C(3°C/min)
- Carrier gas
- He,1.3ml/min
- Detector temp.
- 250°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Methyl Isobutyl Ketone , Toluene , Methyl Butyl Ketone , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , 1,1,2,2-Tetrachloroethane , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Cresol , p-Cresol
- Applications
- The work environment (1)
- Column
- ULBON HR-52
- Column Size
- 30m×0.53mm(5μm)
- Column temp.
- 60°C→130°C(3°C/min)
- Carrier gas
- He,8.0ml/min
- Detector temp.
- 150°C(FID)
- Injection volume
- 1ml
View detail
GC
- Samples
- Methanol , Ethanol , Acetone , n-Propanol , n-Hexane , Ethyl Acetate , Chloroform , Benzene , MIBK , Toluene , Isobutyl Acetate , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cellosolve Acetate
- Applications
- Solvents (1)
- Column
- ULBON HR-52
- Column Size
- 25m×0.32mm(0.5μm)
- Column temp.
- 40°C→90°C(2°C/min)
- Carrier gas
- He,0.83ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , 1,4-Dioxane , Methyl Isobutyl Ketone , Toluene , Methyl n-Butyl Ketone , n-Butyl Acetate , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , o-Xylene , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , 3-Methylcyclohexanol(cis, trans) , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Dichlorobenzene , o-Cresol , p-Cresol
- Applications
- Solvents (3)
- Column
- ULBON HR-52
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→130°C(3°C/min)
- Carrier gas
- He,1.2ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Dichlorvos (DDVP) , Methyldemeton , Methyl parathion , Parathion , EPN
- Applications
- Measurement of organophosphorus compounds using Shinwasorb
- Column
- Silicone OV-17 1% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 180-250℃ (8℃/min)
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- FPD
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- 2,6-Xylenol , o-Cresol , Phenol , 2,4-Xylenol , p-Cresol , m-Cresol , 3,5-Xylenol , 3,4-Xylenol
- Applications
- Measurements of cresol and xylenol isomers using Shinwasorb
- Column
- FAP-S Shinwasorb-U 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 160℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 250℃
- Detector temp.
- 250℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Acetic acid , Propionic acid , Isobutyric acid , Butyric acid , Isovaleric acid , Valeric acid , Isocaproic acid , Capric acid , Enanthic acid
- Applications
- Measurement of short-chain free fatty acids using Shinwasorb -1-
- Column
- Thermon-1000+H3PO4 2.5+0.25% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 150℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 250℃
- Detector temp.
- 240℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Acetic acid , Propionic acid , Isobutyric acid , Butyric acid , Isovaleric acid , Valeric acid , Isocaproic acid , Capric acid , Enanthic acid
- Applications
- Measurement of short-chain free fatty acids using Shinwasorb -2-
- Column
- FAL-M Shinwasorb-S 60/80 PA
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 150℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Mixture of 22 organic solvents
- Applications
- Measurement of organic solvents using Shinwasorb -2-
- Column
- PEG1500 12.5% Shinwasorb-U 40/60
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 60~120℃ (4℃/min)
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Sorbic acid , Dehydroacetic acid , Benzoic acid , trans-Stilbene
- Applications
- Analysis of preservatives using Shinwasorb -1-
- Column
- DEGS+H3PO4 5.0+0.5% Shinwasorb-S 40/60
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 185℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- preservatives
- Applications
- Analysis of preservatives using Shinwasorb -2-
- Column
- Advance-DS+H3PO4 2+0.25% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 200℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- o-Dichlorobenzene, m-Bromochlorobenzene in acetone
- Applications
- Analysis of o-dichlorobenzene using Shinwasorb
- Column
- PEG20M-TPA 2.5% Shinwasorb-U 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 115℃
- Carrier gas
- 39 mL/min N₂ (Adjust so that the retention time of o-dichlorobenzene is about 11 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Acetone , cis-Allethrin , trans-Allethrin
- Applications
- Analysis of allethrin using Shinwasorb Part 2 ~Isomer ratio~
- Column
- Silicone DC QF-1 2.5% Shinwasorb-U 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 165℃
- Carrier gas
- 45 mL/min N₂ (Adjust so that the retention time of trans-allethrin is about 40 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Acetone , Allethrin , Di(2-ethylhexyl) phthalate
- Applications
- Analysis of allethrin using Shinwasorb Part 3
- Column
- Diethyleneglycol Succinate (DEGS) 2.5% Shinwasorb-U 80/100
- Column Size
- 1.1 m x 3.2 mm I.D. Glass
- Column temp.
- 200℃
- Carrier gas
- 36 mL/min N₂ (Adjust so that the retention time of allethrin is about 8 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Acetone , Dichlorvos , 1-chloronaphthalene
- Applications
- Analysis of dichlorvos using Shinwasorb
- Column
- Silicone DC-550 10% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 180℃
- Carrier gas
- 40 mL/min N₂ (Adjust so that the retention time of dichlorvos is about 6 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Acetone , Allethrin , Cinerin I , Jasmolin I , Pyrethrin I , Cinerin II , Jasmolin II , Pyrethrin II
- Applications
- Analysis of pyrethrum extract using Shinwasorb
- Column
- Silicone OV-17 1% Shinwasorb-S 80/100
- Column Size
- 1.1 m x 3.2 mm I.D. Glass
- Column temp.
- 205℃
- Carrier gas
- 35 mL/min N₂(Adjust so that the retention time of Allethrin is about 3 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FPD
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Dichlorvos, Diphenyl in Acetone
- Applications
- Analysis of dichlorvos resin strip using Shinwasorb
- Column
- Silicone OV-11 10% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 170℃
- Carrier gas
- 35 mL/min N₂(Adjust so that the retention time of dichlorvos is about 8 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 3.0 μL
View detail
GC
- Samples
- Diazinon, Di-n-butyl phthalate in Acetone
- Applications
- Analysis of diazinon using Shinwasorb
- Column
- Silicone OV-11 10% Shinwasorb-U 60/80
- Column Size
- 1.6 m x 3.2 mm I.D. Glass
- Column temp.
- 200℃
- Carrier gas
- 25 mL/min N₂(Adjust so that the retention time of diazinon is about 7 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 3.0 μL
View detail
GC
- Samples
- Anhydrous caffeine, Fenitrothion in Acetone
- Applications
- Analysis of Fenitrothion Emulsifiable Concentrate using Shinwasorb
- Column
- Silicone OV-210 3% Shinwasorb-S 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 175℃
- Carrier gas
- 51 mL/min N₂(Adjust so that the retention time of Anhydrous caffeine is about 10 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Anhydrous caffeine, Fenitrothion in Acetone
- Applications
- Analysis of Fenitrothion Microcapsule using Shinwasorb
- Column
- Silicone OV-210 1.5% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 165℃
- Carrier gas
- 50 mL/min N₂(Adjust so that the retention time of diazinon is about 17 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Phthalthrin in Acetone
- Applications
- Analysis of phthalthrin using Shinwasorb ~Isomer ratio phthalthrin~
- Column
- Silicone DC QF-1 2.5% Shinwasorb-S 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 200℃
- Carrier gas
- 40 mL/min N₂( Adjusted so that the retention time of 3.Phthalthrin is about 40 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Organic solvents
- Applications
- Analysis of organic solvents using Sunpak-A -1-
- Column
- Sunpak-A 50/80
- Column Size
- 2.0 m x 3.0 mm I.D. Glass
- Column temp.
- 150℃ ~ 220℃ (3 min hold) program rate 4℃/min
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 250°C
- Detector temp.
- 250°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Organic solvents
- Applications
- Analysis of organic solvents using Sunpak-A -2-
- Column
- Sunpak-A 50/80
- Column Size
- 2.0 m x 3.0 mm I.D. Glass
- Column temp.
- 150℃ ~ 220℃ (3 min hold) program rate 4℃/min
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 250°C
- Detector temp.
- 250°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
LC
- Samples
- Formaldehyde , Methanol , Acetone
- Applications
- Formaldehyde , Methanol , Acetone
- Column
- ULTRON PS-80H
- Column Size
- 300 mm L × 8.0 mm I.D.
- Mobile phase
- HClO4 aq
- Frow rate
- 1.0 mL/min
- Column temp.
- 60°C
- Injection volume
- 10 µL
- Diluent
- mobile phase
View detail