Search result
"Ethylene" Filtered 41 Item.
GC
- Samples
- Ethyleneoxide , Propyleneoxide , Ethanol
- Applications
- Oxirane and propylene oxide in Ethanol (2)
- Column
- Flexol 8N8 25% Chromosorb W 60-80 (AW-DMCS)
- Column Size
- 2.1m×3.2mm
- Column temp.
- 50°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 200°C
- Detector temp.
- 200°C(FID)
View detail
GC
- Samples
- n-Hexane , Methyl Alcohol , Acetone , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Trichloroethylene , Isobutyl Alcohol , Isobutyl Acetate , Toluene , n-Butyl Acetate , Isoamyl Alcohol , Ethylbenzene , m-Xylene , o-Xylene , n-Propylbenzene , Cyclohexanone
- Applications
- Organic solvent in the air (ppm level)
- Column
- SBS-100 10% Shimalite TPA 60-80
- Column Size
- 3.1m×3.2mm
- Column temp.
- 110°C
- Carrier gas
- N2,30ml/min
- Injection port temp.
- 200°C
- Detector temp.
- 200°C(FID)
View detail
GC
- Samples
- Dichloromethane , trans-1,2-Dichloroethylene , Chloroform , 1,2-Dichloroethane , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Toluene , Tetrachloroethylene , Chlorobenzene , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Organic solvents in work environment (3)
- Column
- SBS-300 20% Shimalite W 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,30ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Dichloromethane , trans-1,2-Dichloroethylene , Chloroform , 1,2-Dichloroethane , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Toluene , Tetrachloroethylene , Chlorobenzene , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Chlorinated solvents of the atmosphere (ppm level)
- Column
- SBS-300 20% Shimalite W 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,30ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Methane , Ethane , Ethylene , Propane , Propylene , iso-Butane , n-Butane , 1-Butylene , iso-Butylene , trans-2-Butylene , iso-Pentane , cis-2-Butylene , n-Pentane , 1,3-Butadiene
- Applications
- Lower Hydrocarbons C1〜C5
- Column
- Sebaconitrile 25% Shimalite 60-80 (NAW)
- Column Size
- 12m×3mm(SUS)
- Column temp.
- 40°C
- Carrier gas
- N2,40ml/min
- Injection port temp.
- 40°C
- Detector temp.
- 40°C(FID)
View detail
GC
- Samples
- Air , Carbon Monoxide , Methane , Ethane , Carbon Dioxide , Ethylene
- Applications
- Gas (O2, N2, CO, Methan, Ethan, CO2, Ethylene)
- Column
- Silica Gel 60-80
- Column Size
- 1.6m×3.2mm
- Column temp.
- 50°C
- Carrier gas
- He,60ml/min
- Injection port temp.
- 50°C
- Detector temp.
- 50°C(TCD)
View detail
GC
- Samples
- Chloroform , 1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Chlorodibromomethane , Tetrachloroethylene , Bromoform
- Applications
- Trihalomethane standard mixed sample (2)
- Column
- Silicone DC 200 20% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 80°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 220°C
- Detector temp.
- 220°C(ECD)
View detail
GC
- Samples
- 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Tetrachloroethylene
- Applications
- Trihalomethane under drainage
- Column
- Silicone DC 200 20% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 85°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 220°C
- Detector temp.
- 220°C(ECD)
View detail
GC
- Samples
- Chloroform , 1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Tetrachloroethylene , Chlorodibromomethane , Bromoform
- Applications
- Trihalomethane standard mixed sample (1)
- Column
- Silicone DC 550 20% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 90°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 220°C
- Detector temp.
- 220°C(ECD)
View detail
GC
- Samples
- Methane , Ethane , Ethylene , Propane , Propylene , iso-Butane , n-Butane , 1-Butene , iso-Butene , trans-2-Butene , cis-2-Butene , iso-Pentane , 1,3-Butadiene , n-Pentane ,
- Applications
- Liquefied petroleum gas (LPG)
- Column
- SM-6
- Column Size
- 6.0 m × 3.0 mm Stainless steel
- Column temp.
- 40°C
- Carrier gas
- He, 25 ml/min
- Injection port temp.
- 40°C
- Detector temp.
- 40°C
- Detector
- TCD
- Injection volume
- 1.0 mL
View detail
GC
- Samples
- Methane , Ethane , Ethylene , Propane , iso-Butane , Propylene , n-Butane
- Applications
- Ethane and ethylene in the exhaust gas
- Column
- Squalane 1% Activated Alumina 60-80
- Column Size
- 1.1m×3.2mm
- Column temp.
- 40°C
- Carrier gas
- N2,30ml/min
- Injection port temp.
- 40°C
- Detector temp.
- 40°C(FID)
View detail
GC
- Samples
- Methane , Carbon Dioxide , Ethylene , Ethane , Water
- Applications
- Methane CO2 Ethylene Ethane
- Column
- Sunpak-A
- Column Size
- 2.1m×3.2mm
- Column temp.
- 50°C
- Carrier gas
- He,50ml/min
- Injection port temp.
- 150°C
- Detector temp.
- 150°C(TCD)
View detail
GC
- Samples
- Ethyleneglycol , Diethyleneglycol , Triethyleneglycol
- Applications
- Glycols (1)
- Column
- TENAX TA 60-80
- Column Size
- 1.1m×3.2mm
- Column temp.
- 180°C→210°C(3°C/min)
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- n-Pentane , n-Hexane , n-Heptane , n-Octane , Acrolein , Carbon Tetrachloride , Benzene , Acrylonitrile , Acetonitrile , Perchloroethylene , Toluene , Ethylbenzene , m-Xylene , o-Xylene , n-Dodecane , Styrene monomer , n-Tridecane , p-Xylene
- Applications
- Organic solvent in work environment (1)
- Column
- Thermon-1000 25% Shimalite 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 130°C
- Carrier gas
- N2,40ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- TETA(Triethylene Tetramine) , TEPA(Tetraethylene Pentamine)
- Applications
- TETA and TEPA
- Column
- Thermon-1000+KOH(10%+3%) Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 2.1m×3.2mm
- Column temp.
- 250°C
- Carrier gas
- N2,55ml/min
- Injection port temp.
- 280°C
- Detector temp.
- 280°C(FID)
View detail
GC
- Samples
- Propyleneglycol , Ethyleneglycol , Decyl Alcohol , 1,4-Butanediol , Diethyleneglycol , Lauryl Alcohol , Myristyl Alcohol , Triethyleneglycol , Cetyl Alcohol , Stearyl Alcohol
- Applications
- Glycol and higher alcohol
- Column
- Thermon-3000 1% Shimalite TPA 60-80
- Column Size
- 1.1m×3.2mm
- Column temp.
- 90°C→180°C(5°C/min)
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 260°C
- Detector temp.
- 260°C(FID)
View detail
GC
- Samples
- Solvents
- Applications
- Solvents (5)
- Column
- ULBON HR-1
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→120°C(2°C/min)
- Carrier gas
- He,0.93ml/min
- Detector temp.
- 150°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Methanol , Ethyl Ether , Isopropanol , trans-1,2-Dichloroethylene , Ethyl Acetate , Chloroform , Isobutanol , Trichloroethylene , n-Butanol , 1,4-Dioxane , Toluene , Tetrachloroethylene , n-Butyl Acetate , Ethylbenzene , p-Xylene , Isoamyl Acetate , o-Xylene , n-Amyl Acetate , Cyclohexanol , Cyclohexanone , 2-Methylcyclohexanol , 2-Methylcyclohexanone , p-Dichlorobenzene , o-Dichlorobenzene , o-Cresol , m-Cresol
- Applications
- The work environment (2)
- Column
- ULBON HR-1701
- Column Size
- 30m×0.53mm(5μm)
- Column temp.
- 60°C→180°C(4°C/min)
- Carrier gas
- He,10ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1ml
View detail
GC
- Samples
- Solvents (4)
- Applications
- Solvents (4)
- Column
- ULBON HR-1701
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→180°C(4°C/min)
- Carrier gas
- He,1.4ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- n-Hexane , Ethyl Ether , Acetone , Methyl Acetate , trans-1,2-Dichloroethylene , Methanol , Isopropyl Acetate , Isopropanol , Dichloromethane , n-Propyl Acetate , cis-1,2-Dichloroethylene , Methyl Isobutyl Ketone , Chloroform , Toluene , 1,4-Dioxane , Isobutanol , Isoamyl Acetate , Ethylbenzene , p-Xylene , m-Xylene , Methyl Cellosolve , o-Xylene , Ethyl Cellosolve , Styrene , Cellosolve Acetate , N,N-Dimethylformamide , 4-Methylcyclohexanone , Butyl Cellosolve , cis-4-Methylcyclohexanol , m-Dichlorobenzene , p-Dichlorobenzene , trans-4-Methylcyclohexanol , o-Dichlorobenzene , o-Cresol , p-Cresol , m-Cresol
- Applications
- Solvents (6)
- Column
- ULBON HR-20M
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→240°C(3°C/min)
- Carrier gas
- He,1.3ml/min
- Detector temp.
- 250°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Methyl Isobutyl Ketone , Toluene , Methyl Butyl Ketone , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , 1,1,2,2-Tetrachloroethane , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Cresol , p-Cresol
- Applications
- The work environment (1)
- Column
- ULBON HR-52
- Column Size
- 30m×0.53mm(5μm)
- Column temp.
- 60°C→130°C(3°C/min)
- Carrier gas
- He,8.0ml/min
- Detector temp.
- 150°C(FID)
- Injection volume
- 1ml
View detail
GC
- Samples
- Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , 1,4-Dioxane , Methyl Isobutyl Ketone , Toluene , Methyl n-Butyl Ketone , n-Butyl Acetate , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , o-Xylene , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , 3-Methylcyclohexanol(cis, trans) , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Dichlorobenzene , o-Cresol , p-Cresol
- Applications
- Solvents (3)
- Column
- ULBON HR-52
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→130°C(3°C/min)
- Carrier gas
- He,1.2ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Ethylene oxide , Propylene oxide
- Applications
- Measurement of ethylene oxide using Shinwasorb
- Column
- Flexol 8N8 12.5% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 150℃
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 150℃
- Detector temp.
- 150℃
- Detector
- FID
- Injection volume
- 100 μL
View detail
GC
- Samples
- Dichloromethane , trans-1,2-Dichloroethylene , Chloroform , 1,2-Dichloroethane , 1,1,1-Trichloroethane , Carbon tetrachloride , Trichloroethylene , Toluene , Tetrachloroethylene , Chlorobenzene , 1,1,2,2,-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Measurement of chlorinated solvents in air using Shinwasorb
- Column
- SBS-300 10% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 100℃
- Carrier gas
- 30 mL/min N₂
- Injection port temp.
- 240℃
- Detector temp.
- 240℃
- Detector
- FID
- Injection volume
- 1.0 mL
View detail
GC
- Samples
- 1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Chlorodibromomethane , Tetrachloroethylene , Bromoform
- Applications
- Measurements of trihalomethanes using Shinwasorb -1-
- Column
- Silicone DC-200 10% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 100℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 240℃
- Detector temp.
- 240℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- 1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Chlorodibromomethane , Tetrachloroethylene , Bromoform
- Applications
- Measurements of trihalomethanes using Shinwasorb -2-
- Column
- Silicone DC-550 10% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 90℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 220℃
- Detector temp.
- 220℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Propyleneglycol , 1,3-propanediol
- Applications
- Measurement of food additives using Sunpak-A
- Column
- Sunpak-A 50/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 180℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 230℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Propyleneglycol , 1,3-propanediol
- Applications
- Measurement of food additives using Sunpak-A
- Column
- Sunpak-A 50/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 180℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 230℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Ethylene glycol , Diethylene glycol
- Applications
- Analysis of macrogol 400 using Shinwasorb
- Column
- Sorbitol 3% Shinwasorb-S 80/100
- Column Size
- 1.6 m x 3.2 mm I.D. Glass
- Column temp.
- 160℃
- Carrier gas
- 47 mL/min N2
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Acetone , Allethrin , Di(2-ethylhexyl) phthalate
- Applications
- Analysis of allethrin using Shinwasorb Part 3
- Column
- Diethyleneglycol Succinate (DEGS) 2.5% Shinwasorb-U 80/100
- Column Size
- 1.1 m x 3.2 mm I.D. Glass
- Column temp.
- 200℃
- Carrier gas
- 36 mL/min N₂ (Adjust so that the retention time of allethrin is about 8 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
LC
- Samples
- Ethylene glycol , Diethylene glycol , Methanol , Ethanol , Isopropyl alcohol
- Applications
- Alcohols
- Column
- ULTRON PS-80H
- Column Size
- 300 mm L × 8.0 mm I.D.
- Mobile phase
- H2O
- Frow rate
- 1.0 mL/min
- Column temp.
- 60°C
- Pressure
- 2.5 MPa
- Injection volume
- 6.0 µL (10 mg/mL)
View detail
LC
- Samples
- Formaldehyde , Methanol , Acetone
- Applications
- Formaldehyde , Methanol , Acetone
- Column
- ULTRON PS-80H
- Column Size
- 300 mm L × 8.0 mm I.D.
- Mobile phase
- HClO4 aq
- Frow rate
- 1.0 mL/min
- Column temp.
- 60°C
- Injection volume
- 10 µL
- Diluent
- mobile phase
View detail