Shinwa Chemical Industries Ltd.
LC/GC Search / Application Note

Shinwa Chemical Industries
Application Search

Search result
"n-Propylbenzene" Filtered 9 Item.

Graph

GC

Samples
Benzene , Toluene , Ethylbenzene , Isopropylbenzene , n-Propylbenzene , Styrene Monomer , Cyclopentanol
Applications
Residual styrene monomer in the packaging material
Column
FFAP 20% Chromosorb W 80-100 AW
Column Size
3.1m×3.2mm
Column temp.
130°C
Carrier gas
N2,50ml/min
Injection port temp.
240°C
Detector temp.
240°C(FID)

View detail


Graph

GC

Samples
Benzene , Toluene , Ethylbenzene , Isopropylbenzene , n-Propylbenzene , Styrene Monomer , Cyclopenthanol , N,N-Dimethylformamide
Applications
Styrene monomer in the resin
Column
FON 20% Chromosorb W 80-100 (AW-DMCS)
Column Size
2.1m×3.2mm
Column temp.
110°C
Carrier gas
N2,50ml/min
Injection port temp.
230°C
Detector temp.
230°C(FID)

View detail


Graph

GC

Samples
n-Hexane , Methyl Alcohol , Acetone , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Trichloroethylene , Isobutyl Alcohol , Isobutyl Acetate , Toluene , n-Butyl Acetate , Isoamyl Alcohol , Ethylbenzene , m-Xylene , o-Xylene , n-Propylbenzene , Cyclohexanone
Applications
Organic solvent in the air (ppm level)
Column
SBS-100 10% Shimalite TPA 60-80
Column Size
3.1m×3.2mm
Column temp.
110°C
Carrier gas
N2,30ml/min
Injection port temp.
200°C
Detector temp.
200°C(FID)

View detail


Graph

GC

Samples
Benzene , Acrylonitrile , Toluene , Ethylbenzene , iso-Propylbenzene , n-Propylbenzene , Styrene Monomer , N,N-Dimethylformamide
Applications
Styrene monomer (10ppm) in DMF
Column
ULBON HR-20M
Column Size
30m×0.53mm(5.0μm/min)
Column temp.
120°C
Carrier gas
He,10ml/min
Detector temp.
200°C(FID)
Injection volume
2μl

View detail


Graph

GC

Samples
Benzene , Toluene , Ethylbenzene , p-Xylene , m-Xylene , iso-Propylbenzene , o-Xylene , n-Propylbenzene , p-Ethyltoluene , m-Ethyltoluene , o-Ethyltoluene , 1,2,5-Trimethylbenzene , 1,2,4-Trimethylbenzene , 1,2,3-Trimethylbenzene , Naphthalene
Applications
Aromatic hydrocarbons in Premium gasoline
Column
ULBON HR-20M
Column Size
50m×0.25mm(0.5μm)
Column temp.
50°C→180°C(2°C/min)
Carrier gas
He,1.04ml/min
Detector temp.
250°C(FID)
Injection volume
0.2μl

View detail


Graph

GC

Samples
Benzene , Toluene , Ethylbenzene , p-Xylene , m-Xylene , iso-Propylbenzene , o-Xylene , n-Propylbenzene , p-Ethyltoluene , m-Ethyltoluene , o-Ethyltoluene , 1,2,5-Trimethylbenzene , 1,2,4-Trimethylbenzene , 1,2,3-Trimethylbenzene , Naphthalene
Applications
Aromatic hydrocarbons in Regular gasoline
Column
ULBON HR-20M
Column Size
50m×0.25mm(0.5μm)
Column temp.
50°C→180°C(2°C/min)
Carrier gas
He,1.04ml/min
Detector temp.
250°C(FID)
Injection volume
0.2μl

View detail


Graph

GC

Samples
n-Hexane, Benzene , n-Octane , Toluene , n-Nonane , Ethylbenzene , p-Xylene , m-Xylene , o-Xylene , Isopropylbenzene , Styrene , n-Propylbenzene , p-Ethyltoluene , m-Ethyltoluene , o-Ethyltoluene , 1,3,5-Trimethylbenzene , 1,2,4-Trimethylbenzene , 1,2,3-Trimethylbenzene , 4-n-Propyltoluene , 3-n-Propyltoluene , 2-n-Propyltoluene , 1,2,3,5-Tetramethylbenzene , 1,2,4,5-Tetramethylbenzene , 1,2,3,4-Tetramethylbenzene
Applications
Alkyl benzene isomer
Column
ULBON Xylene Master
Column Size
50m×0.32mm
Column temp.
70°C→120°C(2°C/min)
Carrier gas
He,1.4ml/min
Detector temp.
200°C(FID)
Injection volume
1μl

View detail


Graph

GC

Samples
Benzene , Toluene , Ethylbenzene , Isopropylbenzene , n-Propylbenzene , Styrene monomer , Cyclopentanol , N,N-Dimethylformamide
Applications
Measurement of styrene monomer in DMF using Shinwasorb
Column
FON 10% Shinwasorb-S 60/80
Column Size
2.1 m x 3.2 mm I.D. Glass
Column temp.
110ā„ƒ
Carrier gas
50 mL/min Nā‚‚
Injection port temp.
230ā„ƒ
Detector temp.
230ā„ƒ
Detector
FID
Injection volume
1.0 μL

View detail


Graph

GC

Samples
Benzene , Toluene , Ethylbenzene , Isopropylbenzene , n-Propylbenzene , Styrene monomer , Cyclopentanol , N, N-Dimethylformamide ,
Applications
Measurement of styrene monomer in DMF using Shinwasorb
Column
FFAP 10% Shinwasorb-U 60/80
Column Size
3.1m×3.2mm glass
Column temp.
120°C
Carrier gas
50 mL/min N2
Injection port temp.
240°C
Detector temp.
240°C
Detector
FID
Injection volume
1.0 μL

View detail