Search result
"Shinwasorb" Filtered 70 Item.
GC
- Samples
- Chloroform , Fenitrothion , Fluoranthene
- Applications
- Analysis of fenitrothion using Shinwasorb
- Column
- Polyphenyl Ether (5 rings) 1.5% Shinwasorb-S 100/120
- Column Size
- 1.1 m x 3.2 mm I.D. Glass
- Column temp.
- 195℃
- Carrier gas
- 55 mL/min N₂
- Injection port temp.
- 230℃
- Detector temp.
- 230℃
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Carbonyl sulfide , Hydrogen sulfide , Carbon disulfide , Methyl mercaptan , Ethyl mercaptan , Dimethyl sulfide , Dimethyl disulfide
- Applications
- Analysis of methyl mercaptan, hydrogen sulfide, dimethyl sulfide, and dimethyl disulfide using Shinwasorb
- Column
- β,β’-Oxydipropionitrile 12.5% Shinwasorb-S 60/80 ST
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 70℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 180℃
- Detector temp.
- 180℃
- Detector
- FPD (S)
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Trimethylamine , Dimethylamine , Methylamine
- Applications
- Analysis of methylamines using Shinwasorb
- Column
- Diglycerol+TEP+KOH 7.5+7.5+1% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 70℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 220℃
- Detector temp.
- 220℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- PCBs
- Applications
- Analysis of PCBs using Shinwasorb
- Column
- Silicone OV-17 2% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 210℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- ECD
- Injection volume
- 4.0 μL
View detail
GC
- Samples
- PCBs
- Applications
- Analysis of PCBs using Shinwasorb
- Column
- Silicone OV-1 2% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 195℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- ECD
- Injection volume
- 4.0 μL
View detail
GC
- Samples
- Ethylene oxide , Propylene oxide
- Applications
- Measurement of ethylene oxide using Shinwasorb
- Column
- Flexol 8N8 12.5% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 150℃
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 150℃
- Detector temp.
- 150℃
- Detector
- FID
- Injection volume
- 100 μL
View detail
GC
- Samples
- Dichlorvos (DDVP) , Methyldemeton , Methyl parathion , Parathion , EPN
- Applications
- Measurement of organophosphorus compounds using Shinwasorb
- Column
- Silicone OV-17 1% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 180-250℃ (8℃/min)
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- FPD
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- 2,6-Xylenol , o-Cresol , Phenol , 2,4-Xylenol , p-Cresol , m-Cresol , 3,5-Xylenol , 3,4-Xylenol
- Applications
- Measurements of cresol and xylenol isomers using Shinwasorb
- Column
- FAP-S Shinwasorb-U 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 160℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 250℃
- Detector temp.
- 250℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Ethylbenzene , p-Xylene , m-Xylene , o-Xylene
- Applications
- Measurement of xylene isomers using Shinwasorb
- Column
- Shinchrom F51+Bentone 34 3+2% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 80℃
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 240℃
- Detector temp.
- 240℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Dichloromethane , trans-1,2-Dichloroethylene , Chloroform , 1,2-Dichloroethane , 1,1,1-Trichloroethane , Carbon tetrachloride , Trichloroethylene , Toluene , Tetrachloroethylene , Chlorobenzene , 1,1,2,2,-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Measurement of chlorinated solvents in air using Shinwasorb
- Column
- SBS-300 10% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 100℃
- Carrier gas
- 30 mL/min N₂
- Injection port temp.
- 240℃
- Detector temp.
- 240℃
- Detector
- FID
- Injection volume
- 1.0 mL
View detail
GC
- Samples
- 1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Chlorodibromomethane , Tetrachloroethylene , Bromoform
- Applications
- Measurements of trihalomethanes using Shinwasorb -1-
- Column
- Silicone DC-200 10% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 100℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 240℃
- Detector temp.
- 240℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- 1,1,1-Trichloroethane , Trichloroethylene , Bromodichloromethane , Chlorodibromomethane , Tetrachloroethylene , Bromoform
- Applications
- Measurements of trihalomethanes using Shinwasorb -2-
- Column
- Silicone DC-550 10% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 90℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 220℃
- Detector temp.
- 220℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Acetic acid , Propionic acid , Isobutyric acid , Butyric acid , Isovaleric acid , Valeric acid , Isocaproic acid , Capric acid , Enanthic acid
- Applications
- Measurement of short-chain free fatty acids using Shinwasorb -1-
- Column
- Thermon-1000+H3PO4 2.5+0.25% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 150℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 250℃
- Detector temp.
- 240℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Acetic acid , Propionic acid , Isobutyric acid , Butyric acid , Isovaleric acid , Valeric acid , Isocaproic acid , Capric acid , Enanthic acid
- Applications
- Measurement of short-chain free fatty acids using Shinwasorb -2-
- Column
- FAL-M Shinwasorb-S 60/80 PA
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 150℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Benzene , Toluene , Ethylbenzene , Isopropylbenzene , n-Propylbenzene , Styrene monomer , Cyclopentanol , N,N-Dimethylformamide
- Applications
- Measurement of styrene monomer in DMF using Shinwasorb
- Column
- FON 10% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 110℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 230℃
- Detector temp.
- 230℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Mixture of 22 organic solvents
- Applications
- Measurement of organic solvents using Shinwasorb -2-
- Column
- PEG1500 12.5% Shinwasorb-U 40/60
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 60~120℃ (4℃/min)
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Sorbic acid , Dehydroacetic acid , Benzoic acid , trans-Stilbene
- Applications
- Analysis of preservatives using Shinwasorb -1-
- Column
- DEGS+H3PO4 5.0+0.5% Shinwasorb-S 40/60
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 185℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- preservatives
- Applications
- Analysis of preservatives using Shinwasorb -2-
- Column
- Advance-DS+H3PO4 2+0.25% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 200℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 260℃
- Detector temp.
- 260℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Methyl iodide , iso-Propyl iodide , n-Octane , o-Xylene
- Applications
- Analysis of hypromellose using Shinwasorb
- Column
- Silicone DC-200 10% Shinwasorb-S 100/120
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 90℃
- Carrier gas
- 38 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Carbon sulfide , Hydrogen sulfide , Carbon disulfide , Methyl mercaptan , Ethyl mercaptane , Dimethyl sulfide
- Applications
- Measurements of offensive odor substances using Shinwasorb -3-
- Column
- 1,2,3-TCEP 25% Shinwasorb-S 80/100 ST
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 70℃
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 180℃
- Detector temp.
- 180℃
- Detector
- FPD
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Fragrance
- Applications
- Measurements of fragrance using Shinwasorb
- Column
- Thermon-3000 5% Shinwasorb-S 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 80~260℃(6℃/min)
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 280℃
- Detector temp.
- 280℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Chloroform , Ethanol , Naphthalene , Amantadine
- Applications
- Measurements of amantadine hydrochloride using Shinwasorb
- Column
- Apiezone L+KOH 2+1% Shinwasorb-S 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 125℃(5 min hold)~150℃(5℃/min)~150℃ (10 min hold)
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- 200 ppm in hexane
- Applications
- Measurements of eucalyptus oil using Shinwasorb
- Column
- Thermon-3000 5% Shinwasorb-S 80/100
- Column Size
- 5.1 m x 3.2 mm I.D. Glass
- Column temp.
- 120℃ & 130℃
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Benzene , Toluene , Ethylbenzene , Isopropylbenzene , n-Propylbenzene , Styrene monomer , Cyclopentanol , N, N-Dimethylformamide ,
- Applications
- Measurement of styrene monomer in DMF using Shinwasorb
- Column
- FFAP 10% Shinwasorb-U 60/80
- Column Size
- 3.1m×3.2mm glass
- Column temp.
- 120°C
- Carrier gas
- 50 mL/min N2
- Injection port temp.
- 240°C
- Detector temp.
- 240°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- decane , undecane , dodecane , tridecane , tetradecane , pentadecane , hexadecane , heptadecane , octadecane , nonadecane , eicosane , heneicosane , docosane
- Applications
- Analysis of mixture of kerosene and gas oil using Shinwasorb
- Column
- Silicone SE-52 5% Shinwasorb-U 40/60
- Column Size
- 2.5 m x 3.0 mm I.D. Stainless steel
- Column temp.
- 80~250℃ (6℃/min), 250℃ (12 min hold)
- Carrier gas
- 50 mL/min N2
- Injection port temp.
- 270°C
- Detector temp.
- 270°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Ethyl acetate , di-n-butyl phthalate , Teprenone (mono-cis isomer) , Teprenone (all-trans isomer) , ,
- Applications
- Analysis of teprenone using Shinwasorb -1-
- Column
- FFAP 5% Shinwasorb-U 80/100
- Column Size
- 2.1m×3.2mm glass
- Column temp.
- 235°C
- Carrier gas
- 47 mL/min N2
- Injection port temp.
- 270°C
- Detector temp.
- 270°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- n-valeric acid , valproic acid
- Applications
- Analysis of valproate sodium using Shinwasorb
- Column
- DEGA+H3PO4 2.5+0.5% Shinwasorb-S 80/100
- Column Size
- 2.1m×3.2mm glass
- Column temp.
- 145°C
- Carrier gas
- 35 mL/min N2
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Ethanol , Dl-camphor , Methyl salicylate ,
- Applications
- Analysis of dl-camphor using Shinwasorb
- Column
- PEG 20M 5% Shinwasorb-S 60/80
- Column Size
- 3.1m×3.2mm glass
- Column temp.
- 160°C
- Carrier gas
- 45 mL/min N2
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Ethyl acetate , di-n-butyl phthalate , Teprenone (mono-cis isomer) , Teprenone (all-trans isomer) , ,
- Applications
- Analysis of teprenone using Shinwasorb -2-
- Column
- FFAP 5% Shinwasorb-U 80/100
- Column Size
- 2.1m×3.2mm glass
- Column temp.
- 235°C
- Carrier gas
- 47 mL/min N2
- Injection port temp.
- 270°C
- Detector temp.
- 270°C
- Detector
- FID
- Injection volume
- 2.0 µL
View detail
GC
- Samples
- docosanoic acid methyl , ethyl icosapentate ,
- Applications
- Analysis of ethyl icosapentate using Shinwasorb
- Column
- DEGS 12.5% Shinwasorb-S 60/80
- Column Size
- 1.8 m x 4.0 mm I.D. Glass
- Column temp.
- 210℃
- Carrier gas
- 47 mL/min N2
- Injection port temp.
- 230℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 3.0 μL
View detail
GC
- Samples
- Petroleum ether , Methyl oleate
- Applications
- Analysis of oleic acid using Shinwasorb
- Column
- Shinchrom E71 10% Shinwasorb-U 80/100
- Column Size
- 2.1m×3.2mm
- Column temp.
- 210°C
- Carrier gas
- N2,21 ml/min
- Injection port temp.
- 250°C
- Detector temp.
- 250°C
- Detector
- FID
- Injection volume
- 0.2 μL
View detail
GC
- Samples
- Ethyl acetate , Caffeine , o-Toluene sulfonamide
- Applications
- Analysis of saccharin using Shinwasorb
- Column
- DEGS 1.5% Shinwasorb-S 60/80
- Column Size
- 1.0 m x 3.0 mm I.D. Glass
- Column temp.
- 210°C
- Carrier gas
- N2,55ml/min
- Injection port temp.
- 225°C
- Detector temp.
- 250°C
- Detector
- FID
View detail
GC
- Samples
- Dichloromethane , l-menthol ,
- Applications
- Analysis of l-menthol using Shinwasorb
- Column
- PEG6000 12.5% Shinwasorb-S 60/80
- Column Size
- 2.1m x3.2 mm I.D. Glass
- Column temp.
- 140°C
- Carrier gas
- N2,33ml/min
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 5.0 μL
View detail
GC
- Samples
- Pyridine , N,N-dimethylformamide
- Applications
- Analysis of niceritrol using Shinwasorb
- Column
- PEG20M 5% Shinwasorb-S 80/100
- Column Size
- 3.1m x3.2 mm I.D. Glass
- Column temp.
- 160°C
- Carrier gas
- N2, 55ml/min
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Ethylene glycol , Diethylene glycol
- Applications
- Analysis of macrogol 400 using Shinwasorb
- Column
- Sorbitol 3% Shinwasorb-S 80/100
- Column Size
- 1.6 m x 3.2 mm I.D. Glass
- Column temp.
- 160℃
- Carrier gas
- 47 mL/min N2
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Cyclohexane , N,N-dimethylaniline , Naphthalene ,
- Applications
- Analysis of ampicillin hydrate using Shinwasorb
- Column
- Silicone OV-17 1.5% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 2.6 mm I.D. Glass
- Column temp.
- 105℃
- Carrier gas
- 20 mL/min He(adjust so that the retention time of N,N-dimethylaniline is about 5 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Cyclohexane , Ethyl acetate , 2-propanol ,
- Applications
- Analysis of lenampicillin hydrochloride using Shinwasorb
- Column
- Quadrol 5% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 100℃
- Carrier gas
- 70 mL/min N₂ (Adjust so that the retention time of cyclohexane is about 1 minute.)
- Injection port temp.
- 160°C
- Detector temp.
- 160°C
- Detector
- FID
- Injection volume
- 4.0 μL
View detail
GC
- Samples
- Enflurane , 2-propanol ,
- Applications
- Analysis of enflurane using Shinwasorb
- Column
- DEGS 10% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 80℃
- Carrier gas
- 32 mL/min He (Adjust so that the retention time of enflurane is about 3 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 5.0 μL
View detail
GC
- Samples
- Isoflurane , Ethyl acetate
- Applications
- Analysis of isoflurane using Shinwasorb
- Column
- Igepal CO-880+Ucon LB-550X 5+7.5% Shinwasorb-S 100/120
- Column Size
- 3.5 m x 3.0 mm I.D. Stainless steel
- Column temp.
- 80℃
- Carrier gas
- 37 mL/min N2 (Adjust so that the retention time of isoflurane is about 7 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Cyclohexane , Dicyclohexyl phthalate , Etofenprox
- Applications
- Analysis of etofenprox using Shinwasorb
- Column
- Silicone OV-225 2.5% Shinwasorb-U 60/80
- Column Size
- 1.1m x 3.2 mm I.D. Glass
- Column temp.
- 240℃
- Carrier gas
- 37 mL/min N₂ (Adjust so that the retention time of dicyclohexyl phthalate is about 8 minutes.)
- Injection port temp.
- 250°C
- Detector temp.
- 250°C
- Detector
- FID
- Injection volume
- 3.0 μL
View detail
GC
- Samples
- o-Dichlorobenzene, m-Bromochlorobenzene in acetone
- Applications
- Analysis of o-dichlorobenzene using Shinwasorb
- Column
- PEG20M-TPA 2.5% Shinwasorb-U 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 115℃
- Carrier gas
- 39 mL/min N₂ (Adjust so that the retention time of o-dichlorobenzene is about 11 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Acetone , cis-Allethrin , trans-Allethrin
- Applications
- Analysis of allethrin using Shinwasorb Part 2 ~Isomer ratio~
- Column
- Silicone DC QF-1 2.5% Shinwasorb-U 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 165℃
- Carrier gas
- 45 mL/min N₂ (Adjust so that the retention time of trans-allethrin is about 40 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Acetone , Allethrin , Di(2-ethylhexyl) phthalate
- Applications
- Analysis of allethrin using Shinwasorb Part 3
- Column
- Diethyleneglycol Succinate (DEGS) 2.5% Shinwasorb-U 80/100
- Column Size
- 1.1 m x 3.2 mm I.D. Glass
- Column temp.
- 200℃
- Carrier gas
- 36 mL/min N₂ (Adjust so that the retention time of allethrin is about 8 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Acetone , Dichlorvos , 1-chloronaphthalene
- Applications
- Analysis of dichlorvos using Shinwasorb
- Column
- Silicone DC-550 10% Shinwasorb-S 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 180℃
- Carrier gas
- 40 mL/min N₂ (Adjust so that the retention time of dichlorvos is about 6 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Chloroform , Fenitrothion , Fluoranthene
- Applications
- Analysis of fenitrothion using Shinwasorb
- Column
- Polyphenyl Ether (5 rings) 1.5% Shinwasorb-S 100/120
- Column Size
- 1.1 m x 3.2 mm I.D. Glass
- Column temp.
- 195℃
- Carrier gas
- 55 mL/min N₂ (Adjust so that the retention time of fenitrothion is about 16 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Dichlorvos , Tributyl phosphate
- Applications
- Analysis of dichlorvos using Shinwasorb -2-
- Column
- Silicone OV-225 1% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 170℃
- Carrier gas
- 50 mL/min N₂(Adjust so that the retention time of tributyl phosphate is about 5 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FPD
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Acetone , Allethrin , Cinerin I , Jasmolin I , Pyrethrin I , Cinerin II , Jasmolin II , Pyrethrin II
- Applications
- Analysis of pyrethrum extract using Shinwasorb
- Column
- Silicone OV-17 1% Shinwasorb-S 80/100
- Column Size
- 1.1 m x 3.2 mm I.D. Glass
- Column temp.
- 205℃
- Carrier gas
- 35 mL/min N₂(Adjust so that the retention time of Allethrin is about 3 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FPD
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Dichlorvos, Diphenyl in Acetone
- Applications
- Analysis of dichlorvos resin strip using Shinwasorb
- Column
- Silicone OV-11 10% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 170℃
- Carrier gas
- 35 mL/min N₂(Adjust so that the retention time of dichlorvos is about 8 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 3.0 μL
View detail
GC
- Samples
- Diazinon, Di-n-butyl phthalate in Acetone
- Applications
- Analysis of diazinon using Shinwasorb
- Column
- Silicone OV-11 10% Shinwasorb-U 60/80
- Column Size
- 1.6 m x 3.2 mm I.D. Glass
- Column temp.
- 200℃
- Carrier gas
- 25 mL/min N₂(Adjust so that the retention time of diazinon is about 7 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 3.0 μL
View detail
GC
- Samples
- Anhydrous caffeine, Fenitrothion in Acetone
- Applications
- Analysis of Fenitrothion Emulsifiable Concentrate using Shinwasorb
- Column
- Silicone OV-210 3% Shinwasorb-S 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 175℃
- Carrier gas
- 51 mL/min N₂(Adjust so that the retention time of Anhydrous caffeine is about 10 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Anhydrous caffeine, Fenitrothion in Acetone
- Applications
- Analysis of Fenitrothion Microcapsule using Shinwasorb
- Column
- Silicone OV-210 1.5% Shinwasorb-U 60/80
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 165℃
- Carrier gas
- 50 mL/min N₂(Adjust so that the retention time of diazinon is about 17 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Phthalthrin in Acetone
- Applications
- Analysis of phthalthrin using Shinwasorb ~Isomer ratio phthalthrin~
- Column
- Silicone DC QF-1 2.5% Shinwasorb-S 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 200℃
- Carrier gas
- 40 mL/min N₂( Adjusted so that the retention time of 3.Phthalthrin is about 40 minutes.)
- Injection port temp.
- 230°C
- Detector temp.
- 230°C
- Detector
- FID
- Injection volume
- 1.0 μL