Search result
"ethyl acetate" Filtered 42 Item.
GC
- Samples
- Methyl Alcohol , Ethyl Alcohol , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Methyl Isobutyl Ketone , Toluene , Butyl Acetate , Cellosolve , Ethylbenzene , m-Xylene , p-Xylene , o-Xylene , Cyclohexanone
- Applications
- Organic solvents (2)
- Column
- SBS-1 10% Shimalite TPA 60-80
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,40ml/min
- Injection port temp.
- 230°C
- Detector temp.
- 230°C(FID)
View detail
GC
- Samples
- n-Hexane , Methyl Alcohol , Acetone , Isopropyl Alcohol , Ethyl Acetate , Methyl Ethyl Ketone , Benzene , Trichloroethylene , Isobutyl Alcohol , Isobutyl Acetate , Toluene , n-Butyl Acetate , Isoamyl Alcohol , Ethylbenzene , m-Xylene , o-Xylene , n-Propylbenzene , Cyclohexanone
- Applications
- Organic solvent in the air (ppm level)
- Column
- SBS-100 10% Shimalite TPA 60-80
- Column Size
- 3.1m×3.2mm
- Column temp.
- 110°C
- Carrier gas
- N2,30ml/min
- Injection port temp.
- 200°C
- Detector temp.
- 200°C(FID)
View detail
GC
- Samples
- Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Organic solvent in work environment (2)
- Column
- SBS-200 20% Shimalite W 100-120 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Acetone , Isopropyl Alcohol , n-Hexane , Ethyl Acetate , Chloroform , Carbon Tetrachloride , n-Butyl Alcohol , Methyl Isobutyl Ketone , Isobutyl Acetate , Toluene , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cyclohexanone , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , o-Dichlorobenzene
- Applications
- Organic solvents of the atmosphere (ppm level)
- Column
- SBS-200 20% Shimalite W 100-120 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- Ethyl Acetate , Acetaldehyde-2,4-Dinitrophenylhydrazone
- Applications
- Acetaldehyde -2,4- dinitrophenylhydrazone
- Column
- Silicone OV-17 1% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 2.1m×3.2mm
- Column temp.
- 220°C
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 270°C
- Detector temp.
- 270°C(FID)
View detail
GC
- Samples
- Methanol , Acetaldehyde , Ethanol , Isopropanol , n-Propanol , Ethyl Acetate , Isobutanol , n-Butanol , Isoamyl Alcohol
- Applications
- Lower alcohol in water
- Column
- Thermon-1000 5% Sunpak-A
- Column Size
- 2.1m×3.2mm
- Column temp.
- 180°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 240°C
- Detector temp.
- 240°C(FID)
View detail
GC
- Samples
- α-Pinene , β-Pinene , Limonene , Octyl Aldehyde , Nonyl Aldehyde , Citronellal , Decyl Aldehyde , Linalool , Linalyl Acetate , Isobornyl Acetate(Citronellol) , Menthol , Benzyl Acetate , Perillaldehyde , Geraniol , α-Ionone , Rose-P , C12-Alcohol , Anisaldehyde , Methyl Cinnamate , Ethyl Cinnamate , Eugenol , Heliotropin , DEP , Vanillin , Benzyl Benzoate , Benzyl Salicylate
- Applications
- The mixed sample of perfume component
- Column
- Thermon-3000 5% Chromosorb W 80-100 (AW-DMCS)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 80°C→250°C(6°C/min)
- Carrier gas
- N2,60ml/min
- Injection port temp.
- 290°C
- Detector temp.
- 280°C(FID)
View detail
GC
- Samples
- Dimethyl Ether , Methanol , Isopropanol , Methyl Ethyl Ketone , Isopropyl Acetate , 2-Butanol , n-Propyl Acetate , Isobutanol , Dioxane , Methyl Cellosolve , Toluene , Ethyl Cellosolve , N,N-Dimethylformamide , Chlorobenzene , Cellosolve Acetate , Cyclohexanone , Cyclohexanol , 2-Methyl Cyclohexanone , 2-Methyl Cyclohexanol , o-Dichlorobenzene
- Applications
- Organic solvents (4)
- Column
- Ucon LB 550X 20% Chromosorb W 80-100 (AW)
- Column Size
- 3.1m×3.2mm
- Column temp.
- 100°C
- Carrier gas
- N2,50ml/min
- Injection port temp.
- 230°C
- Detector temp.
- 230°C(FID)
View detail
GC
- Samples
- Solvents
- Applications
- Solvents (5)
- Column
- ULBON HR-1
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→120°C(2°C/min)
- Carrier gas
- He,0.93ml/min
- Detector temp.
- 150°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Methanol , Ethyl Ether , Isopropanol , trans-1,2-Dichloroethylene , Ethyl Acetate , Chloroform , Isobutanol , Trichloroethylene , n-Butanol , 1,4-Dioxane , Toluene , Tetrachloroethylene , n-Butyl Acetate , Ethylbenzene , p-Xylene , Isoamyl Acetate , o-Xylene , n-Amyl Acetate , Cyclohexanol , Cyclohexanone , 2-Methylcyclohexanol , 2-Methylcyclohexanone , p-Dichlorobenzene , o-Dichlorobenzene , o-Cresol , m-Cresol
- Applications
- The work environment (2)
- Column
- ULBON HR-1701
- Column Size
- 30m×0.53mm(5μm)
- Column temp.
- 60°C→180°C(4°C/min)
- Carrier gas
- He,10ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1ml
View detail
GC
- Samples
- Methanol , Ethanol , Acetone , IPA , n-Propanol , Ethyl Acetate , MEK , Chloroform , Benzene , n-Butanol , Toluene , MIBK , Isobutyl Acetate , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cellosolve Acetate
- Applications
- Solvents (2)
- Column
- ULBON HR-1701
- Column Size
- 25m×0.32mm(0.5μm)
- Column temp.
- 40°C→90°C(2°C/min)
- Carrier gas
- He,0.83ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Solvents (4)
- Applications
- Solvents (4)
- Column
- ULBON HR-1701
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→180°C(4°C/min)
- Carrier gas
- He,1.4ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Acetaldehyde , Ethyl Acetate , Ethanol , 1-Propanol , 3-Pentanol , 2-Methyl-1-Butanol , 3-Methyl-1-Butanol
- Applications
- Scotch whisky
- Column
- ULBON HR-20M
- Column Size
- 50m×0.32mm(1.0μm)
- Column temp.
- 60°C→240°C(5°C/min)
- Carrier gas
- He,4.0ml/min
- Detector temp.
- 250°C(FID)
- Injection volume
- 0.6μl
View detail
GC
- Samples
- n-Hexane , Ethyl Ether , Acetone , Methyl Acetate , trans-1,2-Dichloroethylene , Methanol , Isopropyl Acetate , Isopropanol , Dichloromethane , n-Propyl Acetate , cis-1,2-Dichloroethylene , Methyl Isobutyl Ketone , Chloroform , Toluene , 1,4-Dioxane , Isobutanol , Isoamyl Acetate , Ethylbenzene , p-Xylene , m-Xylene , Methyl Cellosolve , o-Xylene , Ethyl Cellosolve , Styrene , Cellosolve Acetate , N,N-Dimethylformamide , 4-Methylcyclohexanone , Butyl Cellosolve , cis-4-Methylcyclohexanol , m-Dichlorobenzene , p-Dichlorobenzene , trans-4-Methylcyclohexanol , o-Dichlorobenzene , o-Cresol , p-Cresol , m-Cresol
- Applications
- Solvents (6)
- Column
- ULBON HR-20M
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→240°C(3°C/min)
- Carrier gas
- He,1.3ml/min
- Detector temp.
- 250°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , Methyl Isobutyl Ketone , Toluene , Methyl Butyl Ketone , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , 1,1,2,2-Tetrachloroethane , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Cresol , p-Cresol
- Applications
- The work environment (1)
- Column
- ULBON HR-52
- Column Size
- 30m×0.53mm(5μm)
- Column temp.
- 60°C→130°C(3°C/min)
- Carrier gas
- He,8.0ml/min
- Detector temp.
- 150°C(FID)
- Injection volume
- 1ml
View detail
GC
- Samples
- Methanol , Ethanol , Acetone , n-Propanol , n-Hexane , Ethyl Acetate , Chloroform , Benzene , MIBK , Toluene , Isobutyl Acetate , n-Butyl Acetate , Ethylbenzene , m-Xylene , o-Xylene , Cellosolve Acetate
- Applications
- Solvents (1)
- Column
- ULBON HR-52
- Column Size
- 25m×0.32mm(0.5μm)
- Column temp.
- 40°C→90°C(2°C/min)
- Carrier gas
- He,0.83ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- Methanol , Acetone , Dichloromethane , trans-1,2-Dichloroethylene , n-Hexane , Ethyl Acetate , Tetrahydrofuran , 1,1,1-Trichloroethane , Carbon Tetrachloride , Trichloroethylene , 1,4-Dioxane , Methyl Isobutyl Ketone , Toluene , Methyl n-Butyl Ketone , n-Butyl Acetate , Tetrachloroethylene , Chlorobenzene , Ethylbenzene , p-Xylene , Styrene , o-Xylene , Butyl Cellosolve , 1,1,2,2-Tetrachloroethane , 3-Methylcyclohexanol(cis, trans) , 2-Methylcyclohexanone , 4-Methylcyclohexanone , m-Dichlorobenzene , p-Dichlorobenzene , o-Dichlorobenzene , o-Cresol , p-Cresol
- Applications
- Solvents (3)
- Column
- ULBON HR-52
- Column Size
- 50m×0.25mm(0.5μm)
- Column temp.
- 60°C→130°C(3°C/min)
- Carrier gas
- He,1.2ml/min
- Detector temp.
- 200°C(FID)
- Injection volume
- 1μl
View detail
GC
- Samples
- α-Pinene , β-Pinene , Limonene , Linalool , Linalyl Acetate , Benzyl Acetate , Phenethyl Alcohol
- Applications
- perfume (1)
- Column
- ULBON HR-Thermon-600T
- Column Size
- 50m×0.25mm
- Column temp.
- 70°C→230°C(4°C/min)
- Carrier gas
- He,1.1ml/min
- Detector temp.
- 250°C(FID)
View detail
GC
- Samples
- β-Pinene , Limonene , Linalool , Linalyl Acetate , Benzyl Acetate , α-Ionene , Phenethyl Alcohol , Lauryl Alcohol , Eugenol , Diethyl Phthalate , Vanillin , Benzyl Salicylate
- Applications
- perfume (2)
- Column
- ULBON HR-Thermon-600T
- Column Size
- 50m×0.25mm
- Column temp.
- 70°C→230°C(4°C/min)
- Carrier gas
- He,1.1ml/min
- Detector temp.
- 250°C(FID)
View detail
GC
- Samples
- Mixture of 22 organic solvents
- Applications
- Measurement of organic solvents using Shinwasorb -2-
- Column
- PEG1500 12.5% Shinwasorb-U 40/60
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 60~120℃ (4℃/min)
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 200℃
- Detector temp.
- 200℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Fragrance
- Applications
- Measurements of fragrance using Shinwasorb
- Column
- Thermon-3000 5% Shinwasorb-S 80/100
- Column Size
- 2.1 m x 3.2 mm I.D. Glass
- Column temp.
- 80~260℃(6℃/min)
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 280℃
- Detector temp.
- 280℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Ethyl acetate , di-n-butyl phthalate , Teprenone (mono-cis isomer) , Teprenone (all-trans isomer) , ,
- Applications
- Analysis of teprenone using Shinwasorb -1-
- Column
- FFAP 5% Shinwasorb-U 80/100
- Column Size
- 2.1m×3.2mm glass
- Column temp.
- 235°C
- Carrier gas
- 47 mL/min N2
- Injection port temp.
- 270°C
- Detector temp.
- 270°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Ethyl acetate , di-n-butyl phthalate , Teprenone (mono-cis isomer) , Teprenone (all-trans isomer) , ,
- Applications
- Analysis of teprenone using Shinwasorb -2-
- Column
- FFAP 5% Shinwasorb-U 80/100
- Column Size
- 2.1m×3.2mm glass
- Column temp.
- 235°C
- Carrier gas
- 47 mL/min N2
- Injection port temp.
- 270°C
- Detector temp.
- 270°C
- Detector
- FID
- Injection volume
- 2.0 µL
View detail
GC
- Samples
- Ethyl acetate , Caffeine , o-Toluene sulfonamide
- Applications
- Analysis of saccharin using Shinwasorb
- Column
- DEGS 1.5% Shinwasorb-S 60/80
- Column Size
- 1.0 m x 3.0 mm I.D. Glass
- Column temp.
- 210°C
- Carrier gas
- N2,55ml/min
- Injection port temp.
- 225°C
- Detector temp.
- 250°C
- Detector
- FID
View detail
GC
- Samples
- Cyclohexane , Ethyl acetate , 2-propanol ,
- Applications
- Analysis of lenampicillin hydrochloride using Shinwasorb
- Column
- Quadrol 5% Shinwasorb-S 60/80
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 100℃
- Carrier gas
- 70 mL/min N₂ (Adjust so that the retention time of cyclohexane is about 1 minute.)
- Injection port temp.
- 160°C
- Detector temp.
- 160°C
- Detector
- FID
- Injection volume
- 4.0 μL
View detail
GC
- Samples
- Isoflurane , Ethyl acetate
- Applications
- Analysis of isoflurane using Shinwasorb
- Column
- Igepal CO-880+Ucon LB-550X 5+7.5% Shinwasorb-S 100/120
- Column Size
- 3.5 m x 3.0 mm I.D. Stainless steel
- Column temp.
- 80℃
- Carrier gas
- 37 mL/min N2 (Adjust so that the retention time of isoflurane is about 7 minutes.)
- Injection port temp.
- 200°C
- Detector temp.
- 200°C
- Detector
- FID
- Injection volume
- 2.0 μL
View detail
GC
- Samples
- Organic solvents
- Applications
- Analysis of organic solvents using Sunpak-A -1-
- Column
- Sunpak-A 50/80
- Column Size
- 2.0 m x 3.0 mm I.D. Glass
- Column temp.
- 150℃ ~ 220℃ (3 min hold) program rate 4℃/min
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 250°C
- Detector temp.
- 250°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Organic solvents
- Applications
- Analysis of organic solvents using Sunpak-A -2-
- Column
- Sunpak-A 50/80
- Column Size
- 2.0 m x 3.0 mm I.D. Glass
- Column temp.
- 150℃ ~ 220℃ (3 min hold) program rate 4℃/min
- Carrier gas
- 50 mL/min N₂
- Injection port temp.
- 250°C
- Detector temp.
- 250°C
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
GC
- Samples
- Diethyl ether , n-Hexane , Methanol , Methyl acetate , 2-Propanol , Ethyl acetate , Tetrahydrofuran , 2-Butanol , iso-Butanol , Toluene , n-Butyl acetate , Methyl n-butyl ketone , iso-Amyl alcohol , Ethylbenzene , m-Xylene , p-Xylene , o-Xylene , Styrene monomer ,
- Applications
- Measurement of organic solvents using SBS-120
- Column
- SBS-120 12% Shincarbon-A2 80/100
- Column Size
- 3.1 m x 3.2 mm I.D. Glass
- Column temp.
- 90℃
- Carrier gas
- 40 mL/min N₂
- Injection port temp.
- 230℃
- Detector temp.
- 230℃
- Detector
- FID
- Injection volume
- 1.0 μL
View detail
LC
- Samples
- Methylphenidate
- Applications
- The central neuron stimulant
- Column
- ULTRON ES-CD
- Column Size
- 150 mm L × 6.0 mm I.D.
- Mobile phase
- 20 mM KH2PO4 (pH 6.0)/CH3CN = 90/10
- Frow rate
- 1.2 mL/min
- Column temp.
- 25°C
View detail
LC
- Samples
- Mepenzolate bromide
- Applications
- Anticholinergic agent
- Column
- ULTRON ES-OVM
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM KH2PO4 (pH 4.6)
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
View detail
LC
- Samples
- Vitamin A , Vitamin D2 , Vitamin D3 , Vitamin E , Tocopherol acetate
- Applications
- Fat-soluble vitamin
- Column
- STR ODS-II
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- CH3CN
- Frow rate
- 1.0 mL/min
- Column temp.
- 40°C
View detail
LC
- Samples
- Montelukast sodium
- Applications
- Analysis of Montelukast sodium
- Column
- ULTRON ES-OVM
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 20 mM KH2PO4 + H3PO4 (pH 3.0)/CH3OH = 60/40
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
- Injection volume
- 2.0 µL
- Diluent
- methanol
View detail
LC
- Samples
- Clopidogrel Related Compound A , Clopidogrel Related Compound B , Clopidogrel Related Compound C , Clopidogrel bisulfate
- Applications
- Analysis of Clopidogrel Related Compounds
- Column
- ULTRON ES-OVM
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- 10 mM KH2PO4/CH3CN = 75/25
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
- Injection volume
- 10.0 µL
View detail
LC
- Samples
- Clopidogrel Related Compound A , Clopidogrel Related Compound B , Clopidogrel Related Compound C , Clopidogrel bisulfate
- Applications
- Analysis of Clopidogrel Related Compounds
- Column
- ULTRON ES-OVM
- Column Size
- 100 mm L × 3.0 mm I.D.
- Mobile phase
- 10 mM KH2PO4/CH3CN = 75/25
- Frow rate
- 1.0 mL/min
- Column temp.
- 25°C
- Injection volume
- 3.0 µL
View detail
LC
- Samples
- Linolenic acid , Myristic acid , Palmitoleic acid , Arachidonic acid , Linoleic acid , Palmitic acid , Oleic acid
- Applications
- Analysis of Long-chain fatty acid
- Column
- STR ODS-Ⅱ
- Column Size
- 150 mm L × 4.6 mm I.D.
- Mobile phase
- CH3CN/0.1% H3PO4 aq = 80/20
- Frow rate
- 1.0 mL/min
- Column temp.
- 40°C
- Injection volume
- 5 µL
- Diluent
- ethyl acetate
View detail